

<!DOCTYPE html>

<html lang="uz-Cyrl-UZ">
<head>
   <!-- Global site tag (gtag.js) - Google Analytics -->
   <script async src="https://www.googletagmanager.com/gtag/js?id=UA-2682682-1"></script>
   <script>
      window.dataLayer = window.dataLayer || [];
      function gtag() { dataLayer.push(arguments); }
      gtag('js', new Date());
      gtag('config', 'UA-2682682-1');
   </script>
<title>

</title><meta charset="UTF-8" /><meta http-equiv="content-type" content="text/html; charset=UTF-8" /><meta name="viewport" content="width=device-width, initial-scale=1.0, minimum-scale=0.3, maximum-scale=3.0" /><link href="/css/mactform.css" rel="stylesheet" type="text/css" />

    <style type="text/css">
        /*.contents-caption DIV {
            float: right;
        }*/

        /*.mobilnav TD {
            height: 32px;
        }*/

        /*.mobilnav {
            border: 0px;
            padding: 0;
            background: url('/image/h-menu.gif') repeat-x scroll left top transparent;
        }*/

        body {
            margin: 0;
        }

        td {
            min-height: 22px;
        }

        /*#userComments {
            position: fixed;
            top: 0;
            left: 200px;
            width: 279px;
            height: 18px;
            background-color: Black;
            color: White;
            z-index: 2000;
            padding: 3px;
            display: none;
        }*/

        /*#fancybox_div {
            display: none;
        }*/

        /*#divContextRasporka {
            width: 270px;
        }*/

        /*#tddivContext {
            background-color: White;
        }*/

        /*#backButton {
            color: White;
            font-weight: bold;
            text-decoration: none;
        }*/

        /*#divCont {
            padding-top: 35px;
        }*/

        /*.main_menu ul .checkboxArea, .main_menu ul .checkboxAreaChecked {
            padding-top: 12px;
        }*/

        /*#item3 > ul > li {
            white-space: nowrap;
        }*/

        /*header > nav > ul > li > a {
            font-family: Arial;
            font-size: 11px;
        }*/

        /*#actContent a {
            font-size: 14px;
            font-family: Arial;
        }*/

        /*#selected_div {
            height: 250px;
            overflow: auto;
            padding: 6px 1px 1px 9px;
        }*/

        /*.enter_submit {
            background: url("/images/bg/search_button_bg.jpg") repeat-x scroll 0 0 transparent;
            border: 1px solid #7190EE;
            border-radius: 6px 6px 6px 6px;
            float: right;
            margin-right: 2px;
            cursor: pointer;
        }*/

        /*.enter_submit > div {
                background: url("/images/arrow/button_uzor4_left.png") no-repeat scroll 4px 7px transparent;
                float: left;
                width: 100%;
                cursor: pointer;
            }*/

        /*.enter_submit input[type="button"] {
                background: url("/images/arrow/button_uzor4_right.png") no-repeat scroll right 7px transparent;
                border: medium none;
                border-radius: 6px 6px 6px 6px;
                color: #FFFFFF;
                float: left;
                font-size: 12px;
                font-weight: bold;
                height: 21px;
                margin-left: 22px;
                margin-right: 4px;
                padding: 0 22px 3px 0;
                cursor: pointer;
            }*/

        .show_context {
            background-color: #FFFF00;
            color: inherit;
        }
    </style>
    <style id="tree_style" type="text/css">
        #divAct a, #divAct DIV, #divAct font, div#theDefCssID table td, th {
            font-size: 12pt;
        }
    </style>

    <script type="text/javascript" charset="utf-8">
        //window.onbeforeunload = function () {
        //    //document.getElementById("main_container").innerHTML = "";
        //    //window.body.style.background = "red";  //css("background", "red");
        //    //window.scrollTo(0, 0);
        //}

        window.onload = function () {
            setTimeout(function () { scrolPage(); }, 100);
        }

        function scrolPage() {
            var hash = location.hash.toString();
            if (hash.length > 2) {
                var elem = document.getElementById(location.hash.toString().substring(1));
                if (elem === null || elem === undefined) {
                    document.body.scrollTop = document.documentElement.scrollTop = 0;
                }
                else {
                    document.body.scrollTop = document.documentElement.scrollTop = elem.offsetTop - 10;
                }
            }
            else {
                document.body.scrollTop = document.documentElement.scrollTop = 0;
            }
        }
    </script>
</head>
<body>
    
    <a href="#DynContent" id="DynContentBtn"></a>
    <div style="display: none;">
        <div id="DynContent" style="width: 350px;">
            <table>
                <tr>
                    <td><span id="dynText"></span></td>
                </tr>
            </table>
        </div>
    </div>
    <div id="headcont">
        
        <header style="z-index: 2000;" id="headermenu">
            <div class='logo' style="padding: 0px 0px 0px 8px">
                <a href='/'><span></span></a>
            </div>
        </header>
        
    </div>
    <div id='main_container'>
        
        <section class='main_text'>
            <table style="width: 100%; font-family: Arial; font-size: 14px; font-weight: bold;">
                <tr>
                    <td style="width: 50%">
                        
                            <div class="act_warning">
                                Акт утратил силу " " 25.03.2026
                            </div>
                        
                        
                        
                    </td>
                    <td style="width: 50%; text-align: right">
                        
                        
                    </td>
                </tr>
            </table>
            <div id="divAct" style="margin: 0px; padding: 0px 5px 0px 5px; background: white;">
                
                <div id="divCont" style="background:#ffffff;border:none;margin:auto;"><div class="INDEXES_ON_REF" style="display:none"><label id="s5987"></label><div name="onLBC973665" id="onLBC973665">[<b>ОКОЗ:</b><div id="LBC9451"><span class="iorRN">1.</span><span class="iorVal">09.00.00.00 Предпринимательство и хозяйственная деятельность / 09.20.00.00 Энергетика / 09.20.05.00 Снабжение тепловой энергией]</span></div></div></div><div class="INDEXES_ON_REF" style="display:none"><label id="s5988"></label><div name="onLS973665" id="onLS973665">[<b>ТСЗ:</b><div id="LS4601"><span class="iorRN">1.</span><span class="iorVal">Экономика / Энергетика]</span></div></div></div><div class="ACT_FORM"><div name="982680" id="982680">Приказ</div></div><div class="ACCEPTING_BODY"><div name="982681" id="982681">НАЧАЛЬНИКА ГОСУДАРСТВЕННОЙ ИНСПЕКЦИИ ПО НАДЗОРУ В ЭЛЕКТРОЭНЕРГЕТИКЕ «УЗГОСЭНЕРГОНАДЗОР»</div></div><div class="ACT_TITLE"><div name="982683" id="982683">ОБ УТВЕРЖДЕНИИ ПРАВИЛ ТЕХНИЧЕСКОЙ ЭКСПЛУАТАЦИИ ТЕПЛОИСПОЛЬЗУЮЩИХ УСТАНОВОК И ТЕПЛОВЫХ СЕТЕЙ</div></div><div class="DEPARTMENTAL"><div name="982686" id="982686">[Зарегистрирован Министерством юстиции Республики Узбекистан 28 февраля 2006 г. Регистрационный № 1549]</div></div><div class="BY_DEFAULT"><div name="982687" id="982687"></div></div><div class="COMMENT"><label id="s527"></label><div class="COMMENTLEXUZ"><img src="/image/favicon.gif"> Комментарий LexUz</img></div></div><div class="COMMENT"><label id="s527"></label><div name="7975341" id="7975341">Настоящий приказ будет выведен из государственного реестра с 25 марта 2026 года в соответствии с <a href="/acts/7938711">приказом </a>министра юстиции Республики Узбекистан от 23 декабря 2025 года № 28-мх «Об исключении некоторых ведомственных нормативно-правовых актов из Государственного реестра ведомственных нормативно-правовых актов» (рег. № 3733 от 23.12.2025 г.).</div></div><div class="ACT_TEXT"><div name="982689" id="982689">На основании <a href="/acts/639973#640138">Положения</a> «О государственной инспекции по надзору в электроэнергетике (Узгосэнергонадзор)», утвержденного постановлением Кабинета Министров Республики Узбекистан от 1 марта 2004 года № 96, приказываю:</div></div><div class="ACT_TEXT"><div name="982690" id="982690">1. Утвердить прилагаемые <a href="/acts/973665#982707">Правила</a> технической эксплуатации теплоиспользующих установок и тепловых сетей.</div></div><div class="ACT_TEXT"><div name="982692" id="982692">2. Ввести в действие настоящий приказ по истечение десяти дней со дня его государственной регистрации в Министерстве юстиции Республики Узбекистан.</div></div><div class="ACT_TEXT"><div name="982693" id="982693">3. Контроль за исполнением настоящего приказа оставляю за собой.</div></div><div class="SIGNATURE"><div name="982694" id="982694">Начальник Государственной инспекции по надзору в электроэнергетике «Узгосэнергонадзор» Б. ГУЛЯМОВ </div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="982696" id="982696">г. Ташкент,</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="982697" id="982697">23 января 2006 г.,</div></div><div class="ACT_ESSENTIAL_ELEMENTS_NUM"><div name="982700" id="982700">№ 15</div></div><div class="BY_DEFAULT"><div name="982707" id="982707"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="982717" id="982717">УТВЕРЖДЕНЫ <br /><a href="/acts/973665">приказом</a> начальника инспекции <br />«Узгосэнергонадзор» <br />от 23 января 2006 года № 15 </div></div><div class="ACT_FORM"><div name="982718" id="982718">ПРАВИЛА </div></div><div class="ACT_TITLE_APPL"><div name="982719" id="982719">технической эксплуатации теплоиспользующих установок и тепловых сетей </div></div><div class="BY_DEFAULT"><div name="982720" id="982720"></div></div><div class="ACT_TEXT"><div name="982722" id="982722">Настоящие Правила в соответствии с <a href="/acts/97258">Законом</a> Республики Узбекистан «Об охране труда» (Ведомости Верховного Совета Республики Узбекистан, 1993 г., № 5, ст. 233) и <a href="/acts/429473">постановлением</a> Кабинета Министров Республики Узбекистан от 29 апреля 1992 г. № 210 «Об организации работы по пересмотру подзаконных актов бывшего Союза ССР» определяют порядок технической эксплуатации теплоиспользующих установок и тепловых сетей, а также обеспечивают надежность, безопасность и эффективности эксплуатации и предотвращения опасных производственных ситуаций.</div></div><div class="ACT_TEXT"><div name="982723" id="982723">Правила переработаны с учетом изменения в структуре и техническом уровне эксплуатации теплоиспользующих установок и тепловых сетей, требований государственных стандартов в области безопасности труда и предназначены для инженерно-технических работников (далее — ИТР) и персонала, занимающихся эксплуатацией, наладкой и ремонтом теплоиспользующих установок и тепловых сетей.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="982727" id="982727">Глава I. Термины и определения</div></div><div class="ACT_TEXT"><div name="982728" id="982728">1. В настоящих Правилах использованы следующие определения и термины:</div></div><div class="ACT_TEXT"><div name="982729" id="982729"><strong>административно-технический персонал</strong> — руководители предприятий, начальники цехов, участков, лабораторий, их заместители, инженеры и техники, мастера, занимающиеся эксплуатационным и ремонтным обслуживанием;</div></div><div class="ACT_TEXT"><div name="982730" id="982730"><strong>бригада</strong> — рабочий коллектив в составе 2 человек и более, включая производителя работ;</div></div><div class="ACT_TEXT"><div name="982731" id="982731"><strong>ввод в эксплуатацию</strong> — событие, фиксирующее готовность тепловых сетей и теплоиспользующих установок к использованию по назначению и документально оформленное в установленном порядке;</div></div><div class="ACT_TEXT"><div name="982732" id="982732"><strong>вращающиеся механизмы</strong> — насосы, вентиляторы и т. п. с электрическим или другим приводом;</div></div><div class="ACT_TEXT"><div name="982733" id="982733"><strong>дежурный персонал</strong> — лица, находящиеся на дежурстве в смене, допущенные к управлению и переключениям оборудования (работники, обслуживающие тепловые пункты, конденсатные станции, диспетчеры по энергоснабжению, работники технологических цехов, обслуживающие теплоиспользующие установки и тепловые сети пр.);</div></div><div class="ACT_TEXT"><div name="982734" id="982734"><strong>допуск</strong> — мероприятие, обеспечивающее правильность подготовки рабочего места, достаточность принятых мер безопасности, необходимых для производства работы, и соответствие их характеру и месту работы по наряду или распоряжению;</div></div><div class="ACT_TEXT"><div name="982735" id="982735"><strong>закрытая водяная система теплоснабжения</strong> — водяная система теплоснабжения, в которой вода, циркулирующая в тепловой сети, используется только как теплоноситель и из сети не отбирается;</div></div><div class="ACT_TEXT"><div name="982737" id="982737"><strong>дублирование</strong> — управление теплоиспользующей установкой и тепловых сетей и несение других функций на рабочем месте, исполняемые под наблюдением лица, ответственного за подготовку дублера;</div></div><div class="ACT_TEXT"><div name="982738" id="982738"><strong>индивидуальный тепловой пункт (далее — ИТП)</strong> — тепловой пункт, обслуживающий здание или его части;</div></div><div class="ACT_TEXT"><div name="982739" id="982739"><strong>инструкция по техническому обслуживанию</strong> — документ, в котором излагаются порядок и правила технического обслуживания изделия (установки);</div></div><div class="ACT_TEXT"><div name="982741" id="982741"><strong>инструкция по эксплуатации</strong> — документ, в котором излагаются сведения, необходимые для правильной эксплуатации (использования, транспортирования, хранения и технического обслуживания) изделия (установки) и поддержания его (ее) в постоянной готовности к действию;</div></div><div class="ACT_TEXT"><div name="982742" id="982742"><strong>источник теплоты (тепловой энергии)</strong> — энергоустановка, предназначенная для производства теплоты (тепловой энергии);</div></div><div class="ACT_TEXT"><div name="982743" id="982743"><strong>наряд</strong> — составленное на специальном бланке задание на безопасное проведение работы, определяющее ее содержание, место, время начала и окончания, необходимые меры безопасности, состав бригады и лиц, ответственных за безопасное выполнение работы;</div></div><div class="ACT_TEXT"><div name="982745" id="982745"><strong>обслуживание оборудования</strong> — эксплуатация, ремонт, наладка и испытание оборудования, а также пусконаладочные работы на нем;</div></div><div class="ACT_TEXT"><div name="982747" id="982747"><strong>оперативно-ремонтный персонал</strong> — категория работников из числа ремонтного персонала, специально обученная и подготовленная для оперативного обслуживания в утвержденном объеме закрепленных за ними тепловых сетей и теплоиспользующих установок;</div></div><div class="ACT_TEXT"><div name="982749" id="982749"><strong>отказ</strong> — событие, заключающееся в нарушении работоспособного состояния объекта;</div></div><div class="ACT_TEXT"><div name="982750" id="982750"><strong>открытая водяная система теплоснабжения</strong> — водяная система теплоснабжения, в которой вода, циркулирующая в тепловой сети, частично или полностью отбирается из системы потребителями теплоты;</div></div><div class="ACT_TEXT"><div name="982751" id="982751"><strong>подготовка рабочего места</strong> — производство необходимых операций по отключению, опорожнению, расхолаживанию, промывке, вентиляции оборудования, предотвращению его ошибочного включения в работу, проверке отсутствия избыточного давления и вредных веществ, установке ограждения, вывешиванию знаков безопасности на данном рабочем месте, обеспечивающих безопасность проведения работ;</div></div><div class="ACT_TEXT"><div name="982752" id="982752"><strong>потребитель тепловой энергии</strong> — предприятие, организация, территориально обособленный цех, строительная площадка и т. п., у которых теплоиспользующие установки присоединены к тепловым сетям источника теплоты теплоснабжающей организации;</div></div><div class="ACT_TEXT"><div name="982753" id="982753"><strong>предприятие</strong> — хозяйствующий субъект (включая его подразделения) созданный для производства продукции, выполнения работ и оказания услуг в целях удовлетворения общественных потребностей и получения прибыли;</div></div><div class="ACT_TEXT"><div name="982755" id="982755"><strong>предохранительные клапаны</strong> — устройства, предохраняющие от превышения давления в котле, сосуде, трубопроводе и т. п. сверхустановленного;</div></div><div class="ACT_TEXT"><div name="982756" id="982756"><strong>рабочее место</strong> — место постоянного или временного пребывания работающих в процессе трудовой деятельности;</div></div><div class="ACT_TEXT"><div name="982757" id="982757"><strong>работы на высоте</strong> — работы, при выполнении которых рабочий находится на высоте 1,3 м и более от поверхности грунта, перекрытия или рабочего настила и на расстоянии менее 2 м от границы перепада по высоте;</div></div><div class="ACT_TEXT"><div name="982759" id="982759"><strong>ремонт </strong>— комплекс операций по восстановлению работоспособности или исправности изделия (установки) и восстановлению его (ее) ресурса или их составных частей;</div></div><div class="ACT_TEXT"><div name="982760" id="982760"><strong>ремонтный персонал</strong> — инженеры, техники, мастера, рабочие, занимающиеся ремонтом теплоиспользующих установок и тепловых сетей;</div></div><div class="ACT_TEXT"><div name="982761" id="982761"><strong>система теплоснабжения</strong> — совокупность взаимосвязанных тепловых сетей, осуществляющих теплоснабжение объекта (здание, цеха, района, города, предприятия и т. д.);</div></div><div class="ACT_TEXT"><div name="982762" id="982762"><strong>система технического обслуживания и ремонта</strong> — совокупность взаимосвязанных средств (документация, процессы технического обслуживания и ремонта и исполнители), необходимых для поддержания и восстановления качества входящих в эту систему установок;</div></div><div class="ACT_TEXT"><div name="982763" id="982763"><strong>системы теплопотребления</strong> — комплекс теплоиспользующих установок с соединительными трубопроводами или тепловыми сетями, которые предназначены для удовлетворения одного или нескольких видов тепловой нагрузки (отопление, вентиляция, горячее водоснабжение, технологические нужды);</div></div><div class="ACT_TEXT"><div name="982766" id="982766"><strong>стажировка </strong>— обучение персонала на рабочем месте под руководством лица, ответственного за обучение, после теоретической подготовки или одновременно с ней в целях практического овладения специальностью, адаптации к объектам обслуживания и управления, приобретения навыков быстрого ориентирования на рабочем месте и других приемов работы;</div></div><div class="ACT_TEXT"><div name="982769" id="982769"><strong>тепловая сеть</strong> — совокупность устройств, предназначенных для передачи тепловой энергии потребителям;</div></div><div class="ACT_TEXT"><div name="982771" id="982771"><strong>тепловой пункт (далее — ТП)</strong> — узел, предназначенный для:</div></div><div class="ACT_TEXT"><div name="982773" id="982773">распределения теплоносителя по видам теплового потребления;</div></div><div class="ACT_TEXT"><div name="982775" id="982775">учета и контроля параметров теплоносителя, режима теплопотребления;</div></div><div class="ACT_TEXT"><div name="982777" id="982777">осуществления оперативных переключений.</div></div><div class="ACT_TEXT"><div name="982780" id="982780"><strong>тепловой узел</strong> — комплекс устройств для присоединения систем теплопотребления к тепловой сети;</div></div><div class="ACT_TEXT"><div name="982782" id="982782"><strong>теплоиспользующая установка</strong> — комплекс устройств, использующих теплоту на цели отопления, вентиляции, горячего водоснабжения и технологические нужды;</div></div><div class="ACT_TEXT"><div name="982786" id="982786"><strong>теплоснабжение </strong>— обеспечение потребителей тепловой энергией;</div></div><div class="INDEXES_ON_REF" style="display:none"><label id="s5989"></label><div name="onTERM982788" id="onTERM982788">[<b>СПиТ:</b><div id="TERM898"><span class="iorRN">1.</span><span class="iorVal">Энерго (тепло) снабжение / Энерго (тепло) снабжающая организация]</span></div></div></div><div class="ACT_TEXT"><div name="982788" id="982788"><strong>теплоснабжающая организация</strong> — юридическое лицо, которое имеет право продажи и распределения теплоэнергии по договору;</div></div><div class="ACT_TEXT"><div name="982791" id="982791"><strong>техническое обслуживание</strong> — комплекс операций или операция по поддержанию работоспособности или исправности изделия (установки) при использовании его (ее) по назначению, хранении или транспортировке;</div></div><div class="ACT_TEXT"><div name="982793" id="982793"><strong>центральный тепловой пункт (далее — ЦТП)</strong> — узел, осуществляющий функции одного или нескольких тепловых пунктов;</div></div><div class="ACT_TEXT"><div name="982794" id="982794"><strong>эксплуатация </strong>— систематическое использование, техническое обслуживание и ремонт теплоиспользующих установок и тепловых сетей;</div></div><div class="INDEXES_ON_REF" style="display:none"><label id="s5989"></label><div name="onTERM982795" id="onTERM982795">[<b>СПиТ:</b><div id="TERM898"><span class="iorRN">1.</span><span class="iorVal">Энерго (тепло) снабжение / Энерго (тепло) снабжающая организация]</span></div></div></div><div class="ACT_TEXT"><div name="982795" id="982795"><strong>энергоснабжающая организация</strong> — поставщик тепловой энергии, являющийся юридическим лицом, имеющий в своем ведении установки, генерирующие тепловую энергию, эксплуатирующей тепловую энергию, эксплуатирующей тепловые сети и обеспечивающий на договорной основе потребителей тепловой энергии.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="982797" id="982797">Глава II. Организация эксплуатации</div></div><div class="TEXT_HEADER_DEFAULT"><div name="982799" id="982799">§ 1. Общие положения</div></div><div class="ACT_TEXT"><div name="982802" id="982802">2. Настоящие Правила распространяются на теплоиспользующие установки: выпарные, ректификационные, сушильные, подогревательные, паровые молоты и т. п., а также на тепловые сети, системы отопления и вентиляции, горячего водоснабжения, сбора и возврата конденсата, теплообменники и теплоизмерительные приборы.</div></div><div class="ACT_TEXT"><div name="982812" id="982812">3. На основе настоящих Правил на предприятиях (организациях), имеющих особые условия производства или специальные теплоиспользующие установки, где в качестве первичного теплоносителя применяются продукты технологии, а также установки, эксплуатация которых не предусмотрена настоящими Правилами, должны быть разработаны местные эксплуатационные инструкции для персонала, обслуживающего эти установки, с учетом характера производства, особенностей оборудования, технологии и т. п., и утверждены руководством данного предприятия (или вышестоящей организации).</div></div><div class="ACT_TEXT"><div name="982813" id="982813">4. По приказу или распоряжению руководителя предприятия должны быть установлены границы разделения функциональных обязанностей и ответственности производственных подразделений и энергослужбы за тепловые сети и теплоиспользующие установки.</div></div><div class="ACT_TEXT"><div name="982814" id="982814">5. Распределение ответственности по использованию тепловой энергии между потребителем и теплоснабжающей организаций определяется договором за пользование тепловой энергией.</div></div><div class="ACT_TEXT"><div name="982815" id="982815">6. Вводимые в эксплуатацию теплоиспользующие установки должны быть изготовлены в соответствии с техническими условиями и отвечать требованиям государственных стандартов.</div></div><div class="ACT_TEXT"><div name="982820" id="982820">7. Устройство, эксплуатация и ремонт теплоиспользующих установок и тепловых сетей, зданий и сооружений должны соответствовать требованиям <a href="/acts/97258">Закона </a>Республики Узбекистан «Об охране труда», «<a href="/acts/1004508#1132074">Правил</a> техники безопасности при эксплуатации теплоиспользующих установок и тепловых сетей» (далее — ПТБ) и иных актов законодательства применительно к данным установкам.</div></div><div class="ACT_TEXT"><div name="982821" id="982821">8. В состав технико-экономической части проектов новых и реконструируемых производств необходимо включать показатели удельных расходов тепловой энергии, а также показатели обобщенных энергозатрат на производство продукции (работы), соответствующие лучшим отраслевым и мировым достижениям.</div></div><div class="ACT_TEXT"><div name="982822" id="982822">9. Организация работы по технике безопасности должна отвечать требованиям <a href="/acts/97258">Закона</a> Республики Узбекистан «Об охране труда», нормативных документов по охране труда и ПТБ.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="982823" id="982823">§ 2. Задачи персонала, ответственность и надзор за выполнением Правил </div></div><div class="ACT_TEXT"><div name="982824" id="982824">10. Персонал, обслуживающий теплоиспользующие установки и тепловые сети, должен ясно представлять технологические особенности своего предприятия (организации), знать и выполнять настоящие Правила, ПТБ, инструкции и другие директивные материалы и должен обеспечить:</div></div><div class="ACT_TEXT"><div name="982825" id="982825">исправное техническое состояние теплоиспользующих установок и тепловых сетей;</div></div><div class="ACT_TEXT"><div name="982826" id="982826">безопасную эксплуатацию теплоиспользующих установок и тепловых сетей;</div></div><div class="ACT_TEXT"><div name="982828" id="982828">надежное снабжение тепловой энергией потребителей.</div></div><div class="ACT_TEXT"><div name="982829" id="982829">11. Лица, ответственные за техническое состояние и безопасную эксплуатацию теплоиспользующих установок и тепловых сетей, теплового хозяйства потребителя тепловой энергии, а также в тепловых и технологических цехах назначаются приказом руководителя из числа ИТР предприятия.</div></div><div class="ACT_TEXT"><div name="982832" id="982832">Остальные персоналы предприятия (организации) осуществляют свою деятельность и несут ответственность в соответствии с настоящими Правилами, также с должностными инструкциями.</div></div><div class="ACT_TEXT"><div name="982834" id="982834">При потреблении тепловой энергии только для отопления, вентиляции и горячего водоснабжения ответственность за исправное состояние и безопасную эксплуатацию теплоиспользующих установок и тепловых сетей предприятия может быть возложена приказом (распоряжением) на специалиста, не имеющего теплотехнического образования, но прошедшего подготовку на специальных курсах и проверку знаний в комиссии предприятия с участием представителей инспекции «Узгосэнергонадзор».</div></div><div class="ACT_TEXT"><div name="982835" id="982835">Необходимость назначения ответственных по цехам и участкам устанавливает руководство предприятия в каждом конкретном случае в зависимости от структуры энергетической службы предприятия, параметров теплоносителей, мощности теплоиспользующих установок и объемов теплопотребления цехов (участков).</div></div><div class="ACT_TEXT"><div name="982836" id="982836">12. Допускается на договорной основе передавать теплоиспользующие установки и тепловые сети на техническое обслуживание и эксплуатацию специализированным организациям или персоналом другого предприятия. При этом ответственность за соблюдение настоящих Правил и условий договора на пользование тепловой энергией с теплоснабжающей организацией сохраняется за предприятием-потребителем.</div></div><div class="ACT_TEXT"><div name="982837" id="982837">13. Администрации малых предприятий и организаций (школы, больницы, магазины, гостиницы, мастерские, столовые и др.), использующие тепловую энергию на нужды отопления и системы горячего водоснабжения, должны обеспечить обслуживание теплоиспользующих установок и тепловых сетей путем передачи их эксплуатации по договору специализированной организации или содержать соответствующий по квалификации персонал. Содержание персонала возможно на долевых началах с другими малыми предприятиями (организациями).</div></div><div class="ACT_TEXT"><div name="982839" id="982839">Во всех случаях на малых предприятиях приказом должно быть назначено лицо, ответственное за тепловое хозяйство обязанное обеспечить выполнение настоящих Правил.</div></div><div class="ACT_TEXT"><div name="982840" id="982840">На малых предприятиях и в организациях, где в штате не предусмотрены должности ИТР, ответственным за тепловое хозяйство может быть назначено лицо из ИТР вышестоящей организации, а при отсутствии вышестоящей организации ответственность возлагается на руководителя. </div></div><div class="ACT_TEXT"><div name="982841" id="982841">Запрещается эксплуатация теплоиспользующих установок и тепловых сетей без наличия соответствующего подготовленного персонала.</div></div><div class="ACT_TEXT"><div name="982843" id="982843">14. Потребители тепловой энергии обязаны обеспечить:</div></div><div class="BY_DEFAULT"><div name="1745804" id="1745804"></div></div><div class="ACT_TEXT"><div name="1745806" id="1745806">надежную, экономичную и безопасную работу теплоиспользующих установок и тепловых сетей и эксплуатацию их в соответствии с требованиями настоящих Правил, ПТБ, «<a href="/acts/1510227#1510741">Правил</a> пользования тепловой энергией», утвержденных постановлением Кабинета Министров от 22 августа 2009 года № 245 (Собрание законодательства Республики Узбекистан, 2009 г., № 35, ст. 382), и других нормативных документов (далее — НД);</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745812" id="1745812">(абзац второй пункта 14 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745306">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="982846" id="982846">соблюдение установленных в договоре на пользование тепловой энергией с теплоснабжающей организацией гидравлических и тепловых режимов потребления тепловой энергии;</div></div><div class="ACT_TEXT"><div name="982847" id="982847">соблюдение графика тепловой нагрузки предприятия (организации) и поддержание заданного режима теплопотребления;</div></div><div class="ACT_TEXT"><div name="982848" id="982848">разработку и внедрение научно обоснованных норм расхода тепловой энергии, мероприятий по ее экономии, увеличению возврата конденсата на источник тепловой энергии, снижение температуры обратной теплофикационной воды, путем использования низкопотенциального тепла для хозяйственных или технологических целей и совершенство схем теплоснабжения;</div></div><div class="ACT_TEXT"><div name="982849" id="982849">внедрение новой техники и технологии, способствующей повышению производительности труда;</div></div><div class="ACT_TEXT"><div name="982850" id="982850">внедрение автоматизированных систем и приборов контроля гидравлических и тепловых режимов, а также учета потребляемой тепловой энергии;</div></div><div class="ACT_TEXT"><div name="982851" id="982851">организацию и своевременное проведение планово-предупредительного и капитального ремонтов теплоиспользующих установок и тепловых сетей, а также обеспечение запасными частями и материалами, необходимыми для бесперебойной работы теплового оборудования;</div></div><div class="ACT_TEXT"><div name="982852" id="982852">подготовку персонала и проверку знаний настоящих Правил, ПТБ, должностных и производственных инструкций;</div></div><div class="ACT_TEXT"><div name="982854" id="982854">выполнение договорных норм по количеству и качеству конденсата, возвращаемого на источник тепловой энергии;</div></div><div class="ACT_TEXT"><div name="982855" id="982855">своевременное и качественное техническое обслуживание и ремонт теплоиспользующих установок и тепловых сетей;</div></div><div class="ACT_TEXT"><div name="982856" id="982856">разработку энергетических балансов предприятия и их анализ;</div></div><div class="ACT_TEXT"><div name="982858" id="982858">выполнение предписаний инспекции «Узгосэнергонадзор» и теплоснабжающей организации в установленные сроки;</div></div><div class="ACT_TEXT"><div name="982859" id="982859">своевременное расследование отказов в работе теплоиспользующих установок и тепловых сетей, а также несчастных случаев, связанных с их эксплуатацией;</div></div><div class="ACT_TEXT"><div name="982860" id="982860">предъявление рекламации заводам-изготовителям при поставке некомплектного, некачественного или не соответствующего заказным спецификациям, государственным стандартам и техническим условиям (далее — ТУ) оборудования;</div></div><div class="ACT_TEXT"><div name="982861" id="982861">монтажным организациям — при некачественном монтаже, отступлениях от проектной документации и повреждениях оборудования в процессе монтажа;</div></div><div class="ACT_TEXT"><div name="982863" id="982863">разработку, совместно с теплоснабжающей организацией, и выполнение согласно договору на пользование тепловой энергией графиков ограничения и отключения теплоиспользующих установок при временном недостатке тепловой энергии и мощности и на источниках теплоты теплоснабжающих организаций;</div></div><div class="ACT_TEXT"><div name="982864" id="982864">разработку с привлечением специалистов технологических и других подразделений, а также специализированных проектных и наладочных организаций перспективных планов, направленных на снижение удельных норм расходов тепловой энергии расходуемых на единицу выпускаемой продукции снижения теплоемкости выпускаемой продукции;</div></div><div class="ACT_TEXT"><div name="982865" id="982865">внедрение энергосберегающих и экологически чистых технологий, утилизационных установок, использующих тепловые вторичные энергоресурсы;</div></div><div class="ACT_TEXT"><div name="982866" id="982866">применение прогрессивных форм экономического стимулирования работ по энергосбережению;</div></div><div class="ACT_TEXT"><div name="982867" id="982867">приемку в эксплуатацию новых и реконструируемых теплоиспользующих установок и тепловых сетей в соответствии требованиям НД и проверку их соответствия требованиям НД.</div></div><div class="ACT_TEXT"><div name="982868" id="982868">15. Каждый случай аварии и отказа в работе теплоиспользующих установок и тепловых сетей должен быть расследован и учтен.</div></div><div class="ACT_TEXT"><div name="982869" id="982869">Разработанные мероприятия по материалам расследования подлежат утверждению руководством предприятия и исполнению в установленные сроки.</div></div><div class="ACT_TEXT"><div name="982870" id="982870">На основе материалов расследования должны быть разработаны противоаварийные мероприятия по предупреждению подобных аварий и отказов в работе.</div></div><div class="ACT_TEXT"><div name="982872" id="982872">16. За аварии и случаи отказов в работе на теплоиспользующих установках и в тепловых сетях несут персональную ответственность:</div></div><div class="ACT_TEXT"><div name="982874" id="982874">а) работники, непосредственно обслуживающие установки и тепловые сети (оперативный, оперативно-ремонтный и технологический персонал), за каждую аварию и отказ в работе, происшедшие по их вине, а также за неправильную ликвидацию любых аварий и отказов в работе на обслуживаемом ими участке;</div></div><div class="ACT_TEXT"><div name="982875" id="982875">б) работники, производящие ремонт оборудования, за каждую аварию и брак в работе, происшедшие из-за низкого качества ремонта, а инженерно-технические работники предприятия — за аварии и отказы в работе, происшедшие из-за несвоевременного проведения ремонта по их вине и некачественной приемки оборудования после ремонта;</div></div><div class="ACT_TEXT"><div name="982876" id="982876">в) старший оперативный персонал — за аварии и отказы, происшедшие по их вине, а также по вине подчиненного им персонала;</div></div><div class="ACT_TEXT"><div name="982877" id="982877">г) руководители (или главные инженеры), главные энергетики (механики), начальники тепло- и энергоцехов, мастера-теплотехники и другие ИТР — за аварии и отказы в работе, происшедшие по их вине, по вине подчиненного им персонала, а также в результате неудовлетворительной организации проведения ремонта и невыполнения противоаварийных мероприятий.</div></div><div class="ACT_TEXT"><div name="982878" id="982878">17. Происшедший каждый несчастный случай, связанный с эксплуатацией теплоиспользующих установок и тепловых сетей, должен быть расследован и учтен в установленном порядке.</div></div><div class="ACT_TEXT"><div name="982879" id="982879">18. Ответственность за несчастные случаи, происшедшие на производстве, несут лица как непосредственно нарушившие Правила, так и те, которые не обеспечили выполнение организационно-технических мероприятий, исключающих возможность возникновения несчастных случаев (соответствие места работы условиям правил техники безопасности, проведение обучения безопасным методам ведения работ и т. п.).</div></div><div class="ACT_TEXT"><div name="982880" id="982880">19. Штат персонала, обслуживающего тепловое хозяйство предприятия (организации), устанавливается руководителем. Однако, он должен быть таким, чтобы обеспечить безусловное выполнение требований настоящих Правил.</div></div><div class="ACT_TEXT"><div name="982881" id="982881">Разделение обязанностей по техническому обслуживанию и эксплуатации теплоиспользующих установок и тепловых сетей между персоналом регламентируется руководством предприятия в должностных инструкциях.</div></div><div class="ACT_TEXT"><div name="982882" id="982882">20. Государственный энергетический надзор за выполнением требований настоящих Правил и ПТБ осуществляет инспекция «Узгосэнергонадзор».</div></div><div class="ACT_TEXT"><div name="982883" id="982883">21. Контроль выполнения на предприятиях требований ПТБ осуществляют службы (отделы) техники безопасности предприятий и их вышестоящие органы.</div></div><div class="ACT_TEXT"><div name="982884" id="982884">22. В случае нарушения договорных условий поставки тепловой энергии со стороны предприятия поставщика лицо, ответственное за общее состояние теплового хозяйства предприятия, подготавливает рекламацию, а в случае непринятия мер по обеспечению условий договора поставщиком обращается в установленном порядке в суд.</div></div><div class="ACT_TEXT"><div name="982885" id="982885">23. Лица, нарушившие настоящие Правила, привлекаются к ответственности в соответствии с законодательством Республики Узбекистан.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="982886" id="982886">§ 3. Подготовка персонала</div></div><div class="ACT_TEXT"><div name="982887" id="982887">24. Эксплуатация теплоиспользующих установок и тепловых сетей предприятия должна осуществляться подготовленным персоналом: специалисты должны иметь образование, соответствующее их должности, а рабочие — подготовку в объеме требований квалификационных характеристик.</div></div><div class="ACT_TEXT"><div name="982888" id="982888">25. На предприятии должна систематически проводиться работа с персоналом, направленная на повышение его производственной квалификации, предупреждение аварийности и травматизма.</div></div><div class="ACT_TEXT"><div name="982889" id="982889">26. Работа с дежурным и оперативно-ремонтным персоналом должна включать:</div></div><div class="ACT_TEXT"><div name="982890" id="982890">а) подготовку к новой должности и стажировку;</div></div><div class="ACT_TEXT"><div name="982891" id="982891">б) проверку знаний настоящих Правил, ПТБ, <a href="/acts/722643#723099">Правил </a>пожарной безопасности для энергетических предприятий (рег. № 1341 от 22 апреля 2004 г.) (далее — ППБ), инструкций и других НД, знание которых предусмотрено должностными инструкциями;</div></div><div class="ACT_TEXT"><div name="982892" id="982892">в) дублирование (исполнение обязанностей под наблюдением опытного работника на его рабочем месте);</div></div><div class="ACT_TEXT"><div name="982893" id="982893">г) проведение инструктажей по безопасности труда и пожарной безопасности;</div></div><div class="ACT_TEXT"><div name="982894" id="982894">д) проведение противоаварийных и противопожарных тренировок;</div></div><div class="ACT_TEXT"><div name="982895" id="982895">е) профессиональное и экономическое обучение.</div></div><div class="ACT_TEXT"><div name="982896" id="982896">27. Работа с персоналом, связанным с техническим обслуживанием, наладкой и испытанием, должна включать:</div></div><div class="ACT_TEXT"><div name="982897" id="982897">подготовку к новой должности и стажировку;</div></div><div class="ACT_TEXT"><div name="982898" id="982898">проверку знаний в объеме требований квалификационных характеристик;</div></div><div class="ACT_TEXT"><div name="982899" id="982899">проведение инструктажей по безопасности труда и пожарной безопасности;</div></div><div class="ACT_TEXT"><div name="982900" id="982900">профессиональное обучение.</div></div><div class="ACT_TEXT"><div name="982901" id="982901">28. Работа со специалистами, непосредственно не занимающимися управлением теплоиспользующими установками и тепловыми сетями или их обслуживанием, должна состоять из подготовки к новой должности, проверки знаний в объеме, предусмотренном должностными инструкциями, а также профессионального и экономического обучения.</div></div><div class="ACT_TEXT"><div name="982902" id="982902">29. Лица, обслуживающие объекты, подконтрольные Государственного надзора, должны проходить обучение, аттестацию, проверку знаний и стажировку в соответствии с требованиями органов Государственного надзора.</div></div><div class="ACT_TEXT"><div name="982903" id="982903">30. До назначения на самостоятельную работу или при переводе на другую работу (должность), связанную с обслуживанием теплоиспользующих установок и тепловых сетей, а также при перерыве в работе свыше 6 месяцев, персонал обязан пройти производственное обучение на рабочем месте.</div></div><div class="ACT_TEXT"><div name="982904" id="982904">Для производственного обучения должен быть представлен срок, достаточный для приобретения практических навыков, ознакомления с оборудованием, аппаратурой и изучения:</div></div><div class="ACT_TEXT"><div name="982905" id="982905">а) настоящих Правил, ПТБ;</div></div><div class="ACT_TEXT"><div name="982906" id="982906">б) технического паспорта, устройства, схем и особенностей эксплуатации теплоиспользующих установок и сетей в необходимом для данной должности объеме;</div></div><div class="ACT_TEXT"><div name="982907" id="982907">в) производственных инструкций;</div></div><div class="ACT_TEXT"><div name="982909" id="982909">г) дополнительных правил и инструкций в зависимости от выполняемой работы.</div></div><div class="ACT_TEXT"><div name="982910" id="982910">Прикрепление обучаемого к обучающему его работнику должно быть оформлено приказом (распоряжением) по предприятию, цеху или участку.</div></div><div class="ACT_TEXT"><div name="982911" id="982911">31. В процессе подготовки к новой должности и стажировки дежурный и оперативно-ремонтный персонал должен:</div></div><div class="ACT_TEXT"><div name="982912" id="982912">усвоить настоящие Правила, ПТБ, ППБ и обучиться их практическому применению;</div></div><div class="ACT_TEXT"><div name="982913" id="982913">изучить схемы, производственные инструкции и инструкции по охране труда, знание которых обязательно для работы в данной должности;</div></div><div class="ACT_TEXT"><div name="982914" id="982914">отработать четкое ориентирование на рабочем месте;</div></div><div class="ACT_TEXT"><div name="982915" id="982915">приобрести необходимые практические навыки в выполнении производственных операций;</div></div><div class="ACT_TEXT"><div name="982916" id="982916">изучить приемы и условия безопасной, безаварийной и экономичной эксплуатации обслуживаемых теплоиспользующих установок и тепловых сетей.</div></div><div class="ACT_TEXT"><div name="982917" id="982917">32. По окончании сроков обучения обучаемый должен пройти в специальной комиссии проверку знаний в объеме требований <a href="/acts/973665#982902">пункта 29</a> настоящих Правил.</div></div><div class="ACT_TEXT"><div name="982918" id="982918">При положительной оценке знаний он может быть допущен к дублированию на срок, установленный комиссией.</div></div><div class="ACT_TEXT"><div name="982919" id="982919">Для ремонтного персонала дублирование не требуется.</div></div><div class="ACT_TEXT"><div name="982920" id="982920">33. Обучение безопасным методам и приемам труда при подготовке рабочих, переподготовке, получении ими второй профессии, повышении квалификации непосредственно на предприятии должен организовать работник, на которого возложены эти функции, при необходимости с привлечением соответствующих специалистов энергослужбы предприятия.</div></div><div class="ACT_TEXT"><div name="982921" id="982921">34. Перечень работ и профессий, по которым проводят обучение, а также порядок, форму, периодичность и продолжительность обучения устанавливает руководитель предприятия по согласованию с профсоюзным комитетом с учетом отраслевых требований и исходя из характеристики профессии, вида работ, специфики производства и условий труда.</div></div><div class="ACT_TEXT"><div name="982922" id="982922">35. Для обучения на основе отраслевых типовых программ разрабатываются учебные программы, которые должны быть утверждены руководителем (или главным инженером) и согласованы отделом (инженером) техники безопасности. Учебные программы должны предусматривать теоретическое и производственное обучение, включая стажировку на рабочем месте.</div></div><div class="ACT_TEXT"><div name="982923" id="982923">36. Теоретическое обучение проводится в рамках специального предмета «Охрана труда» или соответствующего раздела по спецтехнологии в объеме не менее 20 ч при обучении на производстве.</div></div><div class="ACT_TEXT"><div name="982924" id="982924">37. Производственное обучение безопасным методам и приемам труда должно проходить в мастерских, цехах или на рабочих местах, специально созданных на предприятии, под руководством мастера (инструктора) производственного обучения или высококвалифицированного рабочего.</div></div><div class="ACT_TEXT"><div name="982925" id="982925">Продолжительность стажировки должна устанавливаться индивидуально с учетом подготовленности обучаемого и должна составлять от двух до двадцати смен.</div></div><div class="ACT_TEXT"><div name="982926" id="982926">Допуск к стажировке оформляется распорядительным документом.</div></div><div class="ACT_TEXT"><div name="982927" id="982927">По окончании стажировки обучаемый должен пройти первичную проверку знаний, после чего допускается к дублированию.</div></div><div class="ACT_TEXT"><div name="982928" id="982928">38. При перерыве в работе по данному виду работ, должности, профессии более 3 лет, а при работах с повышенной опасностью более 1 года, все рабочие должны пройти обучение безопасным методам и приемам труда до начала самостоятельной работы.</div></div><div class="ACT_TEXT"><div name="982929" id="982929">39. Лица, получившие неудовлетворительную оценку при квалификационной проверке, к самостоятельной работе не допускаются и в течение 1 месяца должны пройти повторную проверку. При получении неудовлетворительной оценки повторной квалификационной проверки лицо к выполнению работ не допускается. Вопрос об использовании такого работника решается администрацией предприятия.</div></div><div class="ACT_TEXT"><div name="982930" id="982930">40. Оперативный и оперативно-ремонтный персонал, имевший перерыв в работе от 3 недель до 2 месяцев, должен пройти дублирование на своем рабочем месте в течение 1-2 смен, а после перерыва в работе от 2 до 6 месяцев — до 6 смен.</div></div><div class="ACT_TEXT"><div name="982931" id="982931">41. Допуск к дублированию персонала оформляется распорядительным документом, в котором указываются срок дублирования и ответственный за подготовку дублера. Программа подготовки дублера, сроки дублирования зависят от сложности обслуживаемого оборудования. Срок дублирования должен быть не менее двух рабочих смен. За все действия дублера на рабочем месте дежурного отвечают в равной мере основной работник и дублер.</div></div><div class="ACT_TEXT"><div name="982932" id="982932">Во время дублирования на рабочем месте обучаемый может производить оперативные переключения, осмотры или другие работы в теплоиспользующей установке только с разрешения и под надзором обучающего.</div></div><div class="ACT_TEXT"><div name="982933" id="982933">Ответственность за правильность действия обучаемого и соблюдения им настоящих Правил, а также ПТБ несет обучающий и сам обучаемый.</div></div><div class="ACT_TEXT"><div name="982934" id="982934">Если в период дублирования будет установлена профессиональная непригодность работника к данной деятельности, его подготовка прекращается. Вопрос о дальнейшем использовании такого работника решает в установленном порядке администрация предприятия.</div></div><div class="ACT_TEXT"><div name="982935" id="982935">42. Допуск к самостоятельной работе вновь принятого или имевшего перерыв в работе более 6 месяцев оперативного и оперативно-ремонтного персонала производится только после инструктажа, стажировки, проверки знаний и дублирования; ремонтного и наладочного персонала — после инструктажа, стажировки и проверки знаний.</div></div><div class="ACT_TEXT"><div name="982936" id="982936">Условия допуска персонала, имевшего перерыв в работе от 3 недель до 6 месяцев, определяется продолжительностью этого перерыва.</div></div><div class="ACT_TEXT"><div name="982937" id="982937">43. Допуск персонала к самостоятельной работе должен быть оформлен распорядительным документом (приказом, распоряжением) руководителя предприятия или структурного подразделения.</div></div><div class="ACT_TEXT"><div name="982938" id="982938">44. Перед допуском к самостоятельной работе оперативный и оперативно-ремонтный персонал, имевший перерыв в работе, должен ознакомиться со следующими изменениями в оборудовании, схемах и режимах работы теплоиспользующих установок и тепловых сетей:</div></div><div class="ACT_TEXT"><div name="982939" id="982939">изменениями в инструкции;</div></div><div class="ACT_TEXT"><div name="982940" id="982940">вновь введенными в действие НД;</div></div><div class="ACT_TEXT"><div name="982941" id="982941">новыми приказами, техническими распоряжениями и другими материалами по данной должности.</div></div><div class="ACT_TEXT"><div name="982942" id="982942">45. Действие допуска к самостоятельной работе лиц, для которых проверка знаний обязательна, сохраняется до срока очередной проверки и может быть прервано решением руководителя предприятия, структурного подразделения или органов государственного надзора при нарушении этими лицами правил, установленных производственными или должностными инструкциями.</div></div><div class="ACT_TEXT"><div name="982944" id="982944">46. Ремонтный и наладочный персонал при перерывах в работе от 1 до 2 месяцев перед допуском к работе должен пройти внеплановый инструктаж, при перерывах в работе от 2 до 6 месяцев — инструктаж и стажировку в течение одной-двух смен, при перерыве в работе свыше 6 месяцев — инструктаж, стажировку и проверку знаний.</div></div><div class="ACT_TEXT"><div name="982945" id="982945">47. Периодическая проверка знаний персонала по настоящим Правилам, ПТБ и производственным инструкциям должна проводиться в следующие сроки:</div></div><div class="ACT_TEXT"><div name="982946" id="982946">а) один раз в 12 месяцев для персонала, непосредственно обслуживающего действующие теплоиспользующие установки и тепловые сети, или проводящие в них наладочные, монтажные и ремонтные работы;</div></div><div class="ACT_TEXT"><div name="982947" id="982947">б) один раз в три года — для ИТР, связанных с эксплуатацией и ремонтом теплоиспользующих установок и тепловых сетей.</div></div><div class="ACT_TEXT"><div name="982948" id="982948">Инженерно-технические работники, относящиеся к оперативному персоналу, подвергаются проверке знаний ежегодно.</div></div><div class="ACT_TEXT"><div name="982949" id="982949">48. Лица, допустившие нарушения настоящих Правил, ПТБ или производственных инструкций, должны подвергаться внеочередной проверке знаний.</div></div><div class="ACT_TEXT"><div name="982950" id="982950">49. Квалификационная проверка знаний настоящих Правил, ПТБ, ППБ, производственных и должностных инструкций должна производиться:</div></div><div class="ACT_TEXT"><div name="982951" id="982951">первичная — перед допуском к самостоятельной работе после обучения и подготовки к новой должности и при переходе с другой работы (должности);</div></div><div class="ACT_TEXT"><div name="982952" id="982952">периодическая — в сроки, указанные в<a href="/acts/973665#982944"> п. 46</a>;</div></div><div class="ACT_TEXT"><div name="982953" id="982953">внеочередная — при нарушении правил и инструкций;</div></div><div class="BY_DEFAULT"><div name="1745814" id="1745814"></div></div><div class="ACT_TEXT"><div name="1745815" id="1745815">по требованию органов инспекции «Узгосэнергонадзор», Государственной инспекции «Саноатгеоконтехназорат», работников технических инспекций профсоюза;</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745816" id="1745816">(абзац пятый пункта 49 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745307">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="982955" id="982955">по заключению комиссий, производящих проверку или расследование нарушений, и по решению вышестоящих организаций;</div></div><div class="ACT_TEXT"><div name="982956" id="982956">в случае установления недостаточных знаний правил, инструкций или неправильных действий персонала при нормальных и аварийных ситуациях;</div></div><div class="ACT_TEXT"><div name="982957" id="982957">при вводе в действие новых правил или нормативных документов по эксплуатации и охране труда;</div></div><div class="ACT_TEXT"><div name="982958" id="982958">при внедрении новых технологических процессов;</div></div><div class="ACT_TEXT"><div name="982959" id="982959">при перерыве в работе более одного года;</div></div><div class="ACT_TEXT"><div name="982960" id="982960">при переводе работника на другое место работы или назначении на другую должность, требующую дополнительных знаний по эксплуатации и охране труда.</div></div><div class="ACT_TEXT"><div name="982961" id="982961">Внеочередная проверка не отменяет сроков периодической проверки по графику (кроме случаев, связанных с вводом в действие новых правил).</div></div><div class="ACT_TEXT"><div name="982963" id="982963">50. Требования к объему знаний по каждой должности, рабочему месту должны устанавливаться в должностных инструкциях.</div></div><div class="ACT_TEXT"><div name="982964" id="982964">Объем знаний по технике безопасности для всех категорий рабочих определяется инструкцией по охране труда.</div></div><div class="ACT_TEXT"><div name="982965" id="982965">51. Проверка знаний каждого работника должна производиться индивидуально. При этом проверяются знания:</div></div><div class="ACT_TEXT"><div name="982966" id="982966">настоящих Правил, правил техники безопасности и пожарной безопасности; должностных и производственных инструкций и схем;</div></div><div class="ACT_TEXT"><div name="982968" id="982968">других НД, знание которых предусмотрено должностными инструкциями;</div></div><div class="ACT_TEXT"><div name="982969" id="982969">52. Проверка знаний настоящих Правил (одновременно ПТЭ и ПТБ) должна производиться квалификационными комиссиями в составе не менее 3 человек:</div></div><div class="ACT_TEXT"><div name="982970" id="982970">а) для лица, ответственного за тепловое хозяйство предприятия (организации), и его заместителя, инженера по технике безопасности — в составе главного инженера или руководителя предприятия (председатель), представителя инспекции «Узгосэнергонадзор» и представителя технической инспекции профсоюза;</div></div><div class="ACT_TEXT"><div name="982971" id="982971">б) для начальников теплоцехов, ответственных за техническое состояние и безопасную эксплуатацию теплоиспользующих установок и тепловых сетей, — в составе лица, ответственного за тепловое хозяйство (или его заместителя), — председатель, представителя отдела техники безопасности, представителя отдела главного энергетика (механика);</div></div><div class="ACT_TEXT"><div name="982972" id="982972">в) для остального ИТР — в составе лица, прошедшего проверку в комиссии согласно <a href="/acts/973665#982971">п. «б»</a>, (председатель), и представителей отдела главного энергетика, отдела техники безопасности и местной профсоюзной организации;</div></div><div class="ACT_TEXT"><div name="982973" id="982973">г) для остальных работников эксплуатационного персонала может быть создано несколько комиссий, состав которых устанавливается Главным энергетиком или лицом, ответственным за эксплуатацию теплоиспользующих установок и сетей;</div></div><div class="ACT_TEXT"><div name="982974" id="982974">д) проверка знаний персонала малых предприятий, использующих тепловую энергию на отопление и горячее водоснабжение, менее 15 Гкал в сутки не проводится. В данном случае ответственное лицо проходит в инспекции «Узгосэнергонадзор» инструктаж по технике безопасности и по безопасному обслуживанию теплоиспользующих установок и тепловых сетей, что должно быть оформлено в журнале учета индивидуальных потребителей.</div></div><div class="ACT_TEXT"><div name="982975" id="982975">Представители инспекции «Узгосэнергонадзор» и технической инспекции профсоюза могут принимать участие в комиссиях по проверке знаний Правил персоналом, указанным в <a href="/acts/973665#982971">пунктах «б»</a>, <a href="/acts/973665#982972">«в»</a>, <a href="/acts/973665#982973">«г»</a>, <a href="/acts/973665#982974">«д»</a> по своему усмотрению.</div></div><div class="ACT_TEXT"><div name="982976" id="982976">Представителей инспекции «Узгосэнергонадзор» и технической инспекции профсоюза необходимо извещать за 10 дней до начала работы комиссии.</div></div><div class="BY_DEFAULT"><div name="1745819" id="1745819"></div></div><div class="ACT_TEXT"><div name="1745821" id="1745821">53. Проверка знаний и допуск к самостоятельной работе рабочих и отдельных категорий специалистов, обслуживающих объекты, поднадзорные Государственной инспекции «Саноатгеоконтехназорат», осуществляется в порядке, установленном Государственной инспекцией «Саноатгеоконтехназорат».</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745822" id="1745822">(пункт 53 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745308">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="982978" id="982978">54. Проверка знаний настоящих Правил (одновременно ПТЭ и ПТБ) должна производиться в комиссии того предприятия (организации), где работает проверяемый (за исключением командированных лиц и лиц, упомянутых в <a href="/acts/973665#982974">п. 52 «д»</a>).</div></div><div class="ACT_TEXT"><div name="982979" id="982979">Результаты проверки знаний заносятся в журнал установленной формы (для технологического персонала (<a href="/acts/973665#983935">приложение № 1</a> к настоящим Правилам).</div></div><div class="ACT_TEXT"><div name="982980" id="982980">Каждому работнику, успешно прошедшему проверку, за исключением технологического персонала, выдается удостоверение установленной формы о проверке знания Правил и инструкций (<a href="/acts/973665#983953">приложение № 2</a> к настоящим Правилам).</div></div><div class="ACT_TEXT"><div name="982981" id="982981">55. Инструктажи по технике безопасности (вводный, первичный на рабочем месте, повторный, внеплановый и текущий) следует проводить для всего персонала, руководителей, непосредственно занятых управлением теплоиспользующими установками и тепловыми сетями и их обслуживанием.</div></div><div class="ACT_TEXT"><div name="982985" id="982985">Целью инструктажей является доведение до персонала основных требований к организации безопасного труда и соблюдению правил техники безопасности; разбор происшедших или возможных ошибок на рабочих местах инструктируемых; углубление знаний и навыков безопасного производства работ; поддержание и углубление знаний правил пожарной безопасности.</div></div><div class="ACT_TEXT"><div name="982988" id="982988">Порядок проведения инструктажей определен в <a href="/acts/417564#418818">Правилах</a> организации работы персоналом на предприятиях энергетического производства (рег. № 1178 от 4 октября 2002 года).</div></div><div class="ACT_TEXT"><div name="982990" id="982990">Проведение инструктажа должно оформляться в журнале.</div></div><div class="ACT_TEXT"><div name="982992" id="982992">56. Противоаварийные тренировки проводятся на рабочих местах или на тренажерных установках. Результаты проведения противоаварийных и противопожарных тренировок заносятся в специальные журналы.</div></div><div class="ACT_TEXT"><div name="982993" id="982993">Периодичность тренировок определяет главный энергетик предприятия, исходя из местных условий. Тренировки проводятся по специальным программам.</div></div><div class="ACT_TEXT"><div name="982994" id="982994">57. Вновь поступившие на работу руководители и специалисты, кроме вводного инструктажа, должны быть также ознакомлены вышестоящими должностными лицами с:</div></div><div class="ACT_TEXT"><div name="982995" id="982995">состоянием условий труда и производственной обстановкой на вверяемом ему объекте (цехе, участке и т. п.);</div></div><div class="ACT_TEXT"><div name="982996" id="982996">состоянием средств защиты рабочих от воздействия опасных и вредных производственных факторов;</div></div><div class="ACT_TEXT"><div name="982997" id="982997">производственным травматизмом и профзаболеваемостью;</div></div><div class="ACT_TEXT"><div name="982998" id="982998">необходимыми мероприятиями по улучшению условий работы и охраны труда;</div></div><div class="ACT_TEXT"><div name="982999" id="982999">руководящими материалами и должностными обязанностями по охране труда.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983003" id="983003">§ 4. Обязанности дежурного персонала</div></div><div class="ACT_TEXT"><div name="983008" id="983008">58. Обслуживание теплоиспользующих установок и тепловых сетей осуществляется:</div></div><div class="ACT_TEXT"><div name="983009" id="983009">а) оперативным персоналом.</div></div><div class="ACT_TEXT"><div name="983010" id="983010">К оперативному персоналу предприятий относятся все работники, обслуживающие тепловые пункты и конденсатные станции, диспетчеры по энергоснабжению;</div></div><div class="ACT_TEXT"><div name="983011" id="983011">б) оперативно-ремонтным персоналом.</div></div><div class="ACT_TEXT"><div name="983012" id="983012">Дежурный персонал технологических, механических и других цехов, обслуживающий внутренние и внешние теплопроводы, системы теплоснабжения, относится к оперативно-ремонтному персоналу;</div></div><div class="ACT_TEXT"><div name="983013" id="983013">в) технологическим персоналом.</div></div><div class="ACT_TEXT"><div name="983014" id="983014">К технологическому персоналу относятся работники технологических цехов, обслуживающие теплоиспользующие установки.</div></div><div class="ACT_TEXT"><div name="983015" id="983015">Границы ответственности за состояние и обслуживание теплопроводов между цехами, а также цехом и отделом главного энергетика (механика) определяются в соответствии с требованиями <a href="/acts/973665#983544">п. 142 </a>настоящих Правил.</div></div><div class="ACT_TEXT"><div name="983016" id="983016">59. Круг обязанностей, права и ответственность дежурного персонала должны быть определены в должностных инструкциях. Кроме должностных инструкций, должны быть разработаны следующие инструкции и документы:</div></div><div class="ACT_TEXT"><div name="983017" id="983017">а) эксплуатационная инструкция;</div></div><div class="ACT_TEXT"><div name="983018" id="983018">б) инструкция по технике безопасности и пожарной безопасности;</div></div><div class="ACT_TEXT"><div name="983019" id="983019">в) инструкция по ликвидации аварий;</div></div><div class="ACT_TEXT"><div name="983020" id="983020">г) технологические карты и тепловые схемы;</div></div><div class="ACT_TEXT"><div name="983021" id="983021">д) инструкции по охране труда.</div></div><div class="ACT_TEXT"><div name="983022" id="983022">Дежурный персонал должен вести следующую оперативную документацию:</div></div><div class="ACT_TEXT"><div name="983023" id="983023">а) оперативный журнал (прием и сдача смены, запись работ по нарядам, вывод в ремонт и прием из ремонта теплоиспользующих установок и тепловых сетей и т. д.);</div></div><div class="ACT_TEXT"><div name="983024" id="983024">б) журнал дефектов и проведенных ремонтов — записи о неисправностях теплоиспользующих установок (тепловых сетей). Указываются дата записи, характер неисправности и ее принадлежность. Запись ответственного за техническое состояние и безопасную эксплуатацию об ознакомлении и устранении дефектов.</div></div><div class="ACT_TEXT"><div name="983026" id="983026">60. Дежурный персонал должен работать по графику, утвержденному начальником цеха (участка). Замена одного дежурного другим допускается только с разрешения начальника цеха (участка) или его заместителя. Дежурство в течение двух смен подряд запрещается.</div></div><div class="ACT_TEXT"><div name="983027" id="983027">61. Каждый дежурный, придя на работу, должен принять смену от предыдущего дежурного, а после окончания работы сдать ее следующему по графику дежурному. Уход с дежурства без сдачи смены запрещается.</div></div><div class="ACT_TEXT"><div name="983029" id="983029">62. При приеме смены дежурный обязан:</div></div><div class="ACT_TEXT"><div name="983030" id="983030">а) ознакомиться со схемой, производственным заданием, состоянием и режимом работы теплоиспользующего оборудования и тепловых сетей, арматуры и приборов на своем участке и произвести личный осмотр их в объеме, установленном должностной инструкцией;</div></div><div class="ACT_TEXT"><div name="983031" id="983031">б) выяснить у сдающего смену, какое тепловое оборудование находится в резерве или ремонте и за каким оборудованием должно быть установлено особо тщательное наблюдение для предупреждения неполадок или аварий;</div></div><div class="ACT_TEXT"><div name="983033" id="983033">в) проверить чистоту рабочего места (оборудования и помещения);</div></div><div class="ACT_TEXT"><div name="983036" id="983036">г) проверить и принять инструмент, материалы, ключи от помещений, журналы и ведомости;</div></div><div class="ACT_TEXT"><div name="983037" id="983037">д) прочитать в журналах все записи и распоряжения за период после своего последнего дежурства;</div></div><div class="ACT_TEXT"><div name="983038" id="983038">е) оформить приемку и сдачу смены записью в журнале за подписями принимающего и сдающего смену. В должностных инструкциях должны быть определены круг обязанностей, права и ответственность дежурного персонала принимающего и сдающего смену;</div></div><div class="ACT_TEXT"><div name="983039" id="983039">ж) сообщить непосредственному начальнику в смене о вступлении на дежурство и о всех недостатках, замеченных при приемке смены;</div></div><div class="ACT_TEXT"><div name="983040" id="983040">з) проверить наличие и принять первичные средства пожаротушения.</div></div><div class="ACT_TEXT"><div name="983041" id="983041">63. Приемка и сдача смены во время ликвидации аварии, производство операций по пуску и остановке теплоиспользующего оборудования запрещается.</div></div><div class="ACT_TEXT"><div name="983042" id="983042">64. Приемка и сдача смены при неисправном оборудовании допускается только с разрешения начальника цеха (участка) или главного энергетика (механика) предприятия.</div></div><div class="ACT_TEXT"><div name="983044" id="983044">65. Дежурный во время своего дежурства является лицом, ответственным за правильное обслуживание и безаварийную работу всего оборудования на порученном ему участке.</div></div><div class="ACT_TEXT"><div name="983045" id="983045">Дежурный должен обеспечить наиболее экономичный и надежный режим работы оборудования в соответствии с утвержденным технологическим режимом и оперативными требованиями вышестоящих дежурных.</div></div><div class="ACT_TEXT"><div name="983046" id="983046">66. Каждый дежурный должен вести запись в оперативном журнале о режимах работы, произведенных переключениях, пусках и остановках теплоиспользующих установок и тепловых сетей, отказах в работе и действиях по восстановлению режимов работы, времени допуска к работам и окончания работ по нарядам с указанием номера наряда и содержания работ.</div></div><div class="ACT_TEXT"><div name="983047" id="983047">67. При нарушении режима работы, повреждении или аварии оборудования дежурный обязан немедленно самостоятельно принять меры к восстановлению нормального режима работы оборудования или к ликвидации аварийного состояния, используя подчиненный ему персонал, и сообщить о происшедшем начальнику смены или другому лицу, заменяющему его.</div></div><div class="ACT_TEXT"><div name="983050" id="983050">68. В случае неправильного действия дежурного эксплуатационного персонала лица технической администрации обязаны вмешаться в ход ликвидации аварии вплоть до отстранения ответственного дежурного, принимая на себя руководство и ответственность за дальнейший ход ликвидации аварии с соответствующей записью в оперативном журнале.</div></div><div class="ACT_TEXT"><div name="983053" id="983053">69. Каждая авария должна быть тщательно расследована. При расследовании аварии должны быть выявлены:</div></div><div class="ACT_TEXT"><div name="983055" id="983055">а) причины возникновения и развития аварии;</div></div><div class="ACT_TEXT"><div name="983056" id="983056">б) конкретные виновники возникновения и развития аварии;</div></div><div class="ACT_TEXT"><div name="983057" id="983057">в) правильность действия персонала;</div></div><div class="ACT_TEXT"><div name="983059" id="983059">г) дефекты и характер повреждения оборудования;</div></div><div class="ACT_TEXT"><div name="983063" id="983063">д) возможности предотвращения подобных аварий в дальнейшем.</div></div><div class="ACT_TEXT"><div name="983064" id="983064">Противоаварийные мероприятия утверждаются руководителем (или главным инженером) предприятия, после чего они являются обязательными к исполнению.</div></div><div class="ACT_TEXT"><div name="983065" id="983065">70. Классификация аварии определяется в соответствии с «Типовой инструкцией по расследованию и учету аварий, брака и прочих нарушений в работе объектов энергетического хозяйства потребителей».</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983067" id="983067">§ 5. Технико-экономические показатели и техническая отчетность</div></div><div class="ACT_TEXT"><div name="983070" id="983070">71. Все предприятия (организации) с потреблением тепловой энергии 15 Гкал (средняя) в сутки и более должны быть оборудованы контрольно-измерительными приборами, дающими возможность определять за сутки, месяц, год:</div></div><div class="ACT_TEXT"><div name="983073" id="983073">а) расход пара, горячей воды и возврат конденсата по предприятию в целом, по каждому цеху предприятия, с разделением расходов на отопления, ГВС и технологические нужды;</div></div><div class="ACT_TEXT"><div name="983074" id="983074">б) количество тепловой энергии, полученной от собственной котельной и от собственной котельной и от источника теплоснабжения;</div></div><div class="ACT_TEXT"><div name="983075" id="983075">в) параметры (температуру и давления) пара, горячей воды и возвращаемого конденсата;</div></div><div class="ACT_TEXT"><div name="983077" id="983077">г) температуру прямой и обратной теплофикационной воды;</div></div><div class="ACT_TEXT"><div name="983079" id="983079">д) величину утечки теплофикационной воды в тепловых сетях и теплоиспользующих установках.</div></div><div class="ACT_TEXT"><div name="983082" id="983082">72. На предприятии необходимо организовать:</div></div><div class="ACT_TEXT"><div name="983084" id="983084">учет расхода теплоносителя и тепловой энергии по предприятию в целом, технологическим и вспомогательным цехам, статьям нормирования и прочим потреблением;</div></div><div class="ACT_TEXT"><div name="983085" id="983085">нормирование, контроль и анализ удельных расходов тепловой энергии;</div></div><div class="ACT_TEXT"><div name="983086" id="983086">анализ технико-экономических показателей для оценки состояния теплоиспользующих установок и тепловых сетей и режимов их работы;</div></div><div class="ACT_TEXT"><div name="983087" id="983087">анализ эффективности проводимых организационно-технических мероприятий по энергосбережению;</div></div><div class="ACT_TEXT"><div name="983088" id="983088">экономическое стимулирование персонала за экономию теплоносителя и тепловой энергии; </div></div><div class="ACT_TEXT"><div name="983089" id="983089">ведение установленной государственной отчетности о результатах использования тепловой энергии</div></div><div class="ACT_TEXT"><div name="983090" id="983090">73. Коммерческий учет расходов теплоносителя и тепловой энергии для расчетов с теплоснабжающей организацией, а также с потребителями тепловой энергии предприятия должен осуществляться в соответствии с <a href="/acts/486520#490788">Правилами</a> пользования тепловой энергией.</div></div><div class="ACT_TEXT"><div name="983091" id="983091">74. Нормирование расхода теплоносителя и тепловой энергии, их фактические удельные расходы и эффективность мероприятий по энергосбережению должны соответствовать ведомственным нормативным документам по нормированию и энергосбережению.</div></div><div class="ACT_TEXT"><div name="983092" id="983092">75. На предприятии должны проводиться энергетические испытания теплоиспользующих установок, по результатам которых разрабатывать в установленные государственным стандартом «Энергобаланс промышленного предприятия. Общие положения» сроки, энергетические балансы и нормативные характеристики, проводиться анализ энергетических балансов и принимать меры к их оптимизации.</div></div><div class="ACT_TEXT"><div name="983093" id="983093">Руководителем (или главным инженером) предприятия обязательно должен быть утвержден перечень теплоиспользующих установок, на которых должны проводиться энергетические испытания.</div></div><div class="ACT_TEXT"><div name="983094" id="983094">В эксплуатационных инструкциях обязательно должны быть приведены или доведены до эксплуатационного персонала в форме режимных карт, таблиц, графиков — энергетические характеристики и нормы отдельных показателей.</div></div><div class="ACT_TEXT"><div name="983095" id="983095">76. Предприятия (организации) обязаны ежегодно составлять пароконденсатный баланс в соответствии с формой <a href="/acts/973665#983987">приложения № 3</a> к настоящим Правилам.</div></div><div class="ACT_TEXT"><div name="983096" id="983096">77. Отчетность по энергетическим показателям промышленные и приравненные к ним предприятия предоставляют по формам и в срок, установленных законодательством Республики Узбекистан.</div></div><div class="ACT_TEXT"><div name="983097" id="983097">78. На промышленных предприятиях с потреблением тепловой энергии 5,0 Гкал/час и более, в случае выявления неиспользованных вторичных энергоресурсов по требованию органов Государственной инспекции «Узгосэнергонадзор», но не реже одного раза в 5 лет должен составляться тепловой баланс.</div></div><div class="ACT_TEXT"><div name="983098" id="983098">79. Ответственный за тепловое хозяйство предприятия должен ежемесячно производить анализ фактического теплового и пароконденсатного баланса всего предприятия и отдельных его цехов и принимать необходимые меры к экономичному использованию тепловой энергии и увеличению возврата конденсата.</div></div><div class="ACT_TEXT"><div name="983099" id="983099">При рассмотрении теплового баланса теплоиспользующих установок необходимо анализировать показатели тепловой эффективности не только каждой теплоиспользующей установки, но и отдельных ее элементов.</div></div><div class="ACT_TEXT"><div name="983101" id="983101">80. На каждом предприятии в соответствии с действующими типовыми положениями должна быть разработана система премирования за экономию тепловой энергии, топлива и возврат конденсата.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983103" id="983103">§ 6. Техническое обслуживание и ремонт теплоиспользующих установок и теплового оборудования </div></div><div class="ACT_TEXT"><div name="983104" id="983104">81. На предприятии должны быть организованы техническое обслуживание и ремонт теплоиспользующих установок и тепловых сетей.</div></div><div class="ACT_TEXT"><div name="983105" id="983105">82. В системе технического обслуживания и ремонта должны быть предусмотрены:</div></div><div class="ACT_TEXT"><div name="983106" id="983106">подготовка технического обслуживания и ремонта;</div></div><div class="ACT_TEXT"><div name="983107" id="983107">вывод оборудования в ремонт;</div></div><div class="ACT_TEXT"><div name="983109" id="983109">оценка технического состояния теплоиспользующих установок и тепловых сетей и составление дефектной ведомости;</div></div><div class="ACT_TEXT"><div name="983110" id="983110">проведение технического обслуживания и ремонта;</div></div><div class="ACT_TEXT"><div name="983111" id="983111">приемка оборудования из ремонта;</div></div><div class="ACT_TEXT"><div name="983112" id="983112">контроль и отчетность о выполнении технического обслуживания и ремонта.</div></div><div class="ACT_TEXT"><div name="983113" id="983113">83. Ответственным за организацию технического обслуживания и ремонта является административно-технический персонал, за которым закреплены теплоиспользующие установки и тепловые сети.</div></div><div class="ACT_TEXT"><div name="983114" id="983114">84. В зависимости от работоспособного состояния теплоиспользующих установок и тепловых сетей должен определяться объем технического обслуживания и ремонта.</div></div><div class="ACT_TEXT"><div name="983115" id="983115">85. Во время технического обслуживания необходимо проводить операции контрольного характера (осмотр, надзор за соблюдением эксплуатационных инструкций, технические испытания и проверки технического состояния) и некоторые технологические операции восстановительного характера (регулирование и под наладку, очистку, смазку, замену вышедших из строя деталей без значительной разборки, устранение различных мелких дефектов).</div></div><div class="ACT_TEXT"><div name="983116" id="983116">86. На все виды планово-предупредительного ремонта должны составляться годовой и месячный графики ремонта теплоиспользующих установок и оборудования, утверждаемые руководителем (или главным инженером) предприятия. Графики ремонта теплоиспользующих установок и оборудования должны быть согласованы с графиками ремонта соответствующего производственного оборудования энергоснабжающей организации (цеха).</div></div><div class="ACT_TEXT"><div name="983117" id="983117">87. Основными видами ремонтов теплоиспользующих установок и тепловых сетей являются капитальный и текущий.</div></div><div class="ACT_TEXT"><div name="983118" id="983118">При проведении капитальных ремонтов должны выполняться также мероприятия, направленные на увеличение длительности непрерывной работы установок и оборудования и улучшение технико-экономических показателей, восстановление и замену изношенных узлов и деталей, а также, при необходимости, модернизацию их с учетом передового опыта эксплуатации и внедрения новой техники.</div></div><div class="ACT_TEXT"><div name="983119" id="983119">При текущем ремонте теплоиспользующей установки и оборудования должны производиться работы по его осмотру, очистке и ремонту, обеспечивающие до следующего ремонта нормальную эксплуатацию с номинальной мощностью, производительностью и экономичностью.</div></div><div class="ACT_TEXT"><div name="983121" id="983121">88. При проведении текущего и капитального ремонта теплоиспользующих установок и тепловых сетей должен одновременно производиться ремонт относящегося к ним вспомогательного оборудования.</div></div><div class="ACT_TEXT"><div name="983122" id="983122">При наличии резерва вспомогательного оборудования допускается проведение его ремонта в период между капитальными ремонтами основного оборудования.</div></div><div class="ACT_TEXT"><div name="983123" id="983123">89. До вывода в капитальный ремонт каждой теплоиспользующей установки и другого теплового оборудования должны быть проведены следующие подготовительные мероприятия:</div></div><div class="ACT_TEXT"><div name="983125" id="983125">а) составлены ведомости дефектов и объема работ, которые уточняются после вскрытия и осмотра установки;</div></div><div class="ACT_TEXT"><div name="983126" id="983126">б) составлен график проведения ремонтных работ;</div></div><div class="ACT_TEXT"><div name="983127" id="983127">в) заготовлены, согласно ведомостям дефектов и объема работ, необходимые материалы и запасные части и первичные средства пожаротушения;</div></div><div class="ACT_TEXT"><div name="983129" id="983129">г) укомплектованы и приведены в исправность инструменты, приспособления, такелажное оборудование и подъемно-транспортные механизмы;</div></div><div class="ACT_TEXT"><div name="983130" id="983130">д) подготовлены рабочие места для ремонта, произведена планировка площадки с указанием мест размещения частей и деталей;</div></div><div class="ACT_TEXT"><div name="983131" id="983131">е) укомплектованы ремонтные бригады, обеспечивающие выполнение всего объема работ в намеченные сроки.</div></div><div class="ACT_TEXT"><div name="983134" id="983134">90. Документация по капитальному ремонту теплоиспользующих установок и тепловых сетей должна быть составлена в установленном порядке и утверждена руководителем (или главным инженером) предприятия.</div></div><div class="ACT_TEXT"><div name="983135" id="983135">Конструктивные изменения теплоиспользующих установок оборудования и изменения принципиальных тепловых схем при выполнении ремонтов могут производиться только по утвержденному проекту.</div></div><div class="ACT_TEXT"><div name="983137" id="983137">91. График ремонта должен быть согласован с ремонтными работами других цехов на данном участке. В графике должно быть указано распределение работ между рабочими бригадами и ответственными руководителями по участкам.</div></div><div class="ACT_TEXT"><div name="983138" id="983138">92. Организация ремонта и контроль за его проведением должны осуществляться лицом, за которым закреплено ремонтируемое оборудование.</div></div><div class="ACT_TEXT"><div name="983139" id="983139">93. Для ремонта теплоиспользующих установок и тепловых сетей на предприятии должны быть в наличии необходимые запасные части и материалы в соответствии с номенклатурой, утвержденной руководителем (или главным инженером) предприятия.</div></div><div class="ACT_TEXT"><div name="983141" id="983141">94. На предприятии должен вестись точный учет наличия запасных частей и запасного оборудования и аварийных материалов, которые должны пополняться по мере их расходования при ремонтах.</div></div><div class="ACT_TEXT"><div name="983142" id="983142">95. При хранении запасных частей и запасного оборудования должна быть обеспечена их сохранность от порчи и коррозии.</div></div><div class="ACT_TEXT"><div name="983144" id="983144">Теплоизоляционные и другие материалы, теряющие при увлажнении свои качества, должны храниться в закрытых складах или под навесом.</div></div><div class="ACT_TEXT"><div name="983145" id="983145">96. Приемка теплоиспользующей установки и теплового оборудования из капитального ремонта должна производиться рабочей комиссией, назначенной приказом по предприятию (организации).</div></div><div class="ACT_TEXT"><div name="983146" id="983146">Приемка из текущего ремонта производится лицами, ответственными за ремонт, техническое состояние и безопасную эксплуатацию данной тепловой установки.</div></div><div class="ACT_TEXT"><div name="983147" id="983147">97. При приемке теплоиспользующей установки и теплового оборудования после ремонта должно быть проведено выполнение всех работ, перечисленных в дефектной ведомости, и произведены приемочные испытания, после чего дана качественная оценка ремонта.</div></div><div class="ACT_TEXT"><div name="983149" id="983149">98. Работы, выполняемые при капитальном ремонте теплоиспользующей установки и теплового оборудования, принимаются по акту. К акту приемки должна быть приложена вся техническая документация по выполненному ремонту (эскизы, фотографии, акты промежуточных приемок по отдельным узлам и протоколы промежуточных испытаний, исполнительный график ремонта и др.).</div></div><div class="ACT_TEXT"><div name="983150" id="983150">99. Акты приемки установок и оборудования из ремонта со всеми документами должны храниться при паспортах.</div></div><div class="ACT_TEXT"><div name="983151" id="983151">Все изменения, выявленные и произведенные во время ремонта, должны вноситься в паспорта, схемы и чертежи.</div></div><div class="ACT_TEXT"><div name="983152" id="983152">100. Организационная структура ремонтного производства, технология ремонтных работ, порядок подготовки и вывода в ремонт, а также приемки и оценки состояния отремонтированных теплоиспользующих установок и тепловых сетей должны соответствовать отраслевым НД.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983154" id="983154">§ 7. Техническая документация</div></div><div class="ACT_TEXT"><div name="983155" id="983155">101. На каждую теплоиспользующую установку необходимо иметь:</div></div><div class="ACT_TEXT"><div name="983156" id="983156">а) паспорт установленной формы с протоколами и актами испытаний, осмотров и ремонтов;</div></div><div class="ACT_TEXT"><div name="983157" id="983157">б) рабочие чертежи оборудования;</div></div><div class="ACT_TEXT"><div name="983158" id="983158">в) сертификаты;</div></div><div class="ACT_TEXT"><div name="983159" id="983159">г) исполнительные схемы всех трубопроводов с нумерацией арматуры и расстановкой контрольно-измерительных приборов;</div></div><div class="ACT_TEXT"><div name="983160" id="983160">д) инструкцию по эксплуатации и ремонту;</div></div><div class="ACT_TEXT"><div name="983161" id="983161">е) положение о правах и обязанностях персонала;</div></div><div class="ACT_TEXT"><div name="983162" id="983162">ж) акты об освидетельствовании скрытых работ, об индивидуальных испытаниях теплоиспользующих установок, технологических трубопроводов, систем горячего водоснабжения, отопления и вентиляции, тепловых сетей;</div></div><div class="ACT_TEXT"><div name="983163" id="983163">з) акты промежуточных приемок и акты приемки в эксплуатацию тепловых сетей, тепловых пунктов, насосных станций, теплоиспользующих установок рабочими и государственными комиссиями.</div></div><div class="ACT_TEXT"><div name="983164" id="983164">102. Руководство предприятия должно определить, какая техническая документация необходима для дежурного и оперативно-ремонтного персонала и обеспечить ею рабочие места.</div></div><div class="ACT_TEXT"><div name="983165" id="983165">103. Полный комплект схем и чертежей теплоиспользующих установок должен храниться в техническом архиве. Оперативные схемы и чертежи установок должны находиться у начальника цеха (участка) и на рабочем месте дежурного персонала.</div></div><div class="ACT_TEXT"><div name="983166" id="983166">Необходимые схемы должны быть вывешены на видном месте в помещении дежурного персонала. Информация об изменениях в схемах должна доводиться до сведения всех работников, для которых обязательно знание этих схем, записью в журнале распоряжений или иным способом.</div></div><div class="ACT_TEXT"><div name="983167" id="983167">Не реже 1 раза в 3 года должны проводиться проверки соответствия оперативных схем действительному состоянию всех элементов системы теплоснабжения предприятия.</div></div><div class="ACT_TEXT"><div name="983168" id="983168">104. Схемы и чертежи должны точно соответствовать существующим условиям. Всякое изменение в установке, оборудовании, приборах и т. п. должно немедленно вноситься в соответствующий чертеж или схему с обязательным указанием кем, когда и по какой причине сделано то или иное изменение.</div></div><div class="ACT_TEXT"><div name="983169" id="983169">105. В должностных инструкциях для каждого рабочего места должны быть указаны:</div></div><div class="ACT_TEXT"><div name="983170" id="983170">а) перечень инструкций и других НД, схем установок, знание которых обязательно для работника; </div></div><div class="ACT_TEXT"><div name="983171" id="983171">б) права, обязанности и ответственность персонала;</div></div><div class="ACT_TEXT"><div name="983172" id="983172">в) взаимоотношения работника с вышестоящим, подчиненным и другим, связанным по работе персоналом.</div></div><div class="ACT_TEXT"><div name="983173" id="983173">106. На каждом рабочем месте должны находиться эксплуатационные инструкции и наглядная схема обслуживаемого оборудования с его основными характеристиками.</div></div><div class="ACT_TEXT"><div name="983174" id="983174">В эксплуатационной инструкции должны быть четко указаны:</div></div><div class="ACT_TEXT"><div name="983175" id="983175">а) последовательность операции пуска и остановки оборудования;</div></div><div class="ACT_TEXT"><div name="983176" id="983176">б) порядок эксплуатации оборудования во время нормальной работы и меры, принимаемые при возникновении аварии;</div></div><div class="ACT_TEXT"><div name="983177" id="983177">в) порядок допуска к ремонту оборудования;</div></div><div class="ACT_TEXT"><div name="983178" id="983178">г) меры безопасности и противопожарные меры.</div></div><div class="ACT_TEXT"><div name="983180" id="983180">При наличии особых условий, указанных в <a href="/acts/973665#982812">п. 3</a>, дополнительно в эксплуатационной инструкции указываются права, обязанности, взаимоотношения и ответственность обслуживающего персонала.</div></div><div class="ACT_TEXT"><div name="983181" id="983181">Инструкции по обслуживанию оборудования должны быть составлены в соответствии с типовыми инструкциями по эксплуатации этого оборудования на основе заводских данных и инструкций, эксплуатационных и противоаварийных циркуляров и других директивных материалов, а также опыта эксплуатации с учетом местных условий и особенностей оборудования.</div></div><div class="ACT_TEXT"><div name="983182" id="983182">По усмотрению администрации, с учетом сложности установки, могут быть разработаны дополнительно инструкции по ее техническому обслуживанию и техническое описание.</div></div><div class="ACT_TEXT"><div name="983183" id="983183">107. Инструкции должны быть подписаны начальником цеха, согласованы с главным энергетиком (механиком) и утверждены руководителем (или главным инженером) предприятия.</div></div><div class="ACT_TEXT"><div name="983184" id="983184">Инструкции должны пересматриваться и переутверждаться не реже 1 раза в 3 года и каждый раз при изменении условий эксплуатации с учетом изменений, произведенных в схемах и оборудовании, внедрения новой технологии, а также с учетом издаваемых руководящих материалов.</div></div><div class="ACT_TEXT"><div name="983185" id="983185">Все существенные изменения и дополнения, внесенные в действующие инструкции, должны быть доведены записью в журнале распоряжений или иным способом до сведения работников, для которых их знание обязательно.</div></div><div class="ACT_TEXT"><div name="983186" id="983186">108. В инструкциях должны быть строго разграничены работы по обслуживанию и ремонту оборудования между персоналом отдела главного энергетика (механика) предприятия и производственного цеха и указан перечень лиц, для которых знание данной инструкции обязательно.</div></div><div class="ACT_TEXT"><div name="983187" id="983187">109. В инструкциях по охране труда должны быть указаны общие требования безопасности, требования безопасности труда перед началом работы, во время работы, при отказах оборудования и по окончании работы.</div></div><div class="BY_DEFAULT"><div name="1745823" id="1745823"></div></div><div class="ACT_TEXT"><div name="1745824" id="1745824">110. Все теплоиспользующие установки (сосуды), регистрируемые и не регистрируемые в Государственной инспекции «Саноатгеоконтехназорат» в соответствии с требованиями к устройству и безопасной эксплуатации сосудов, работающих под давлением, должны учитываться владельцами в специальной книге учета и освидетельствований сосудов, хранящейся у лица, осуществляющего надзор за установками (сосудами) на предприятии или ответственного за техническое состояние и безопасную эксплуатацию теплоиспользующих установок.</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745828" id="1745828">(пункт 110 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745309">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="983189" id="983189">111. Кроме паспорта на трубопровод должна быть составлена следующая документация:</div></div><div class="ACT_TEXT"><div name="983190" id="983190">1. Исполнительная схема трубопровода с указанием на ней:</div></div><div class="ACT_TEXT"><div name="983191" id="983191">а) диаметров труб;</div></div><div class="ACT_TEXT"><div name="983192" id="983192">б) расположения опор, компенсаторов, арматуры, спускных продувочных и дренажных устройств и контрольно-измерительных приборов.</div></div><div class="ACT_TEXT"><div name="983193" id="983193">2. Свидетельства о качестве изготовления и монтажа трубопроводов.</div></div><div class="ACT_TEXT"><div name="983194" id="983194">3. Акт приемки в эксплуатацию трубопровода владельцем его от монтажной организации.</div></div><div class="ACT_TEXT"><div name="983195" id="983195">4. Паспорта и другая документация на сосуды, являющиеся неотъемлемой частью трубопровода (водоотделители, грязевики и т. п.). Указанные паспорта должны соответствовать требованиям Правил котлонадзора, Правил устройства и безопасной эксплуатации трубопроводов пара и горячей воды.</div></div><div class="ACT_TEXT"><div name="983464" id="983464">112. Дежурный персонал должен вести оперативную документацию, в соответствии со следующим перечнем документов дежурного персонала:</div></div><div class="ACT_TEXT"><div name="983465" id="983465">а) оперативный журнал — регистрация в хронологическом порядке (с точностью до минуты) оперативных действий, производимых для обеспечения заданного режима теплоиспользующей установки (тепловых сетей), распоряжений вышестоящего и административно-технического персонала. Записи о неисправностях и отказах оборудования и мерах по восстановлению нормального режима. Сведения о первичных и ежедневных допусках к работам по нарядам и распоряжениям. Записи о приеме и сдаче смены с регистрацией состояния оборудования (в работе, ремонте, резерве);</div></div><div class="ACT_TEXT"><div name="983466" id="983466">б) оперативная схема тепловых сетей (водяных, паровых, конденсатных) — схема тепловых сетей с указанием на ней диаметров и номеров трубопроводов, арматуры, спускных, продувочных и дренажных устройств;</div></div><div class="ACT_TEXT"><div name="983467" id="983467">в) оперативная схема теплоиспользующей установки — схема теплоиспользующей установки с подводящими и отводящими трубопроводами с указанием запорной и регулирующей арматуры, с обозначением и нумерацией спускных, продувочных и дренажных устройств;</div></div><div class="ACT_TEXT"><div name="983468" id="983468">г) журнал распоряжений — запись распоряжений руководства предприятия, руководящего персонала энергослужбы;</div></div><div class="ACT_TEXT"><div name="983469" id="983469">д) журнал учета работ по нарядам и распоряжениям — в соответствии с ПТБ;</div></div><div class="ACT_TEXT"><div name="983470" id="983470">е) журнал заявок на вывод оборудования из работы — регистрация заявок на вывод оборудования из работы от цехов (участков) с указанием наименования оборудования, причины и времени вывода его из работы (подачи заявки), а также объема теплопотребления отключаемого оборудования;</div></div><div class="ACT_TEXT"><div name="983471" id="983471">ж) журнал дефектов — записи о неисправностях теплоиспользующих установок (тепловых сетей). Указываются дата записи, характер неисправности и ее принадлежность. Запись ответственного за техническое состояние и безопасную эксплуатацию об ознакомлении и устранении дефектов;</div></div><div class="ACT_TEXT"><div name="983472" id="983472">з) бланк переключений — запись об объемах переключений, времени их начала и окончания, условиях, проведения; сведения о персонале, выполняющем переключения, указания о последовательности переключений, положений запорной и регулирующей арматуры после их окончания;</div></div><div class="ACT_TEXT"><div name="983473" id="983473">и) фамилия работника, контролирующего ход переключений и несущего за них ответственность;</div></div><div class="ACT_TEXT"><div name="983474" id="983474">к) температурный график центрального регулирования системы теплоснабжения — график зависимости температур сетевой воды в подающих и обратных трубопроводах тепловой сети от температуры наружного воздуха;</div></div><div class="ACT_TEXT"><div name="983475" id="983475">л) режимная карта — документ, содержащий перечень оптимальных значений параметров для достижения надежной и экономичной эксплуатации теплоиспользующих установок и тепловых сетей.</div></div><div class="ACT_TEXT"><div name="983476" id="983476">В зависимости от местных условий перечень оперативных документов может быть изменен решением руководителя (или главного энергетика) предприятия.</div></div><div class="ACT_TEXT"><div name="983477" id="983477">113. Административно-технический персонал должен ежедневно проверять оперативную документацию и принимать меры к устранению дефектов оборудования системы теплоснабжения предприятия и нарушений в работе, допущенных персоналом.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983478" id="983478">§ 8. Допуск в эксплуатацию</div></div><div class="ACT_TEXT"><div name="983479" id="983479">114. Теплоиспользующие установки, где строительные и монтажные работы закончены (на новостройках и при расширении предприятия), вводятся в эксплуатацию после приемки их ведомственными и Государственными комиссиями с обязательным участием в комиссии местных органов Государственной инспекции «Узгосэнергонадзор».</div></div><div class="ACT_TEXT"><div name="983481" id="983481">Все вновь смонтированные, реконструированные и модернизированные теплоиспользующие установки, тепловые сети и измерительные средства тепловой энергии потребителей, должны выполнятся в соответствии с КМК и государственными стандартами. Теплоиспользующие установки и измерительные средства тепловой энергии должны иметь сертификат или сертификат соответствия.</div></div><div class="BY_DEFAULT"><div name="1745840" id="1745840"></div></div><div class="ACT_TEXT"><div name="1745841" id="1745841">115. Все принимаемые в эксплуатацию теплоиспользующие установки должны быть выполнены в соответствии с проектом и удовлетворять требованиям настоящих Правил, правил Государственной инспекции «Саноатгеоконтехназорат», <a href="/acts/1510227#1510741">Правил</a> пользования тепловой энергией.</div></div><div class="ACT_TEXT"><div name="1745843" id="1745843">Теплоиспользующие установки, выполненные без проекта и с нарушением действующих правил, к эксплуатации не допускаются.</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745845" id="1745845">(пункт 115 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745310">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="BY_DEFAULT"><div name="1745848" id="1745848"></div></div><div class="ACT_TEXT"><div name="1745850" id="1745850">116. Ввод в эксплуатацию вновь смонтированных теплоиспользующих установок (сосудов) и трубопроводов, подлежащих регистрации в органах Государственной инспекции «Саноатгеоконтехназорат», осуществляется после осмотра инспектора котлонадзора.</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745851" id="1745851">(пункт 116 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745310">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="BY_DEFAULT"><div name="1745868" id="1745868"></div></div><div class="ACT_TEXT"><div name="1745884" id="1745884">117. Ввод в эксплуатацию установок и трубопроводов, не регистрируемых в органах Государственной инспекции «Саноатгеоконтехназорат», осуществляется ответственным за техническое состояние и безопасную эксплуатацию теплоиспользующих установок (сосудов) и трубопроводов, на основании проверки документации и результатов произведенного им технического освидетельствования с записью в паспорте.</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745885" id="1745885">(пункт 117 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745311">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="983488" id="983488">118. До ввода теплоиспользующих установок в промышленную эксплуатацию должны производиться:</div></div><div class="ACT_TEXT"><div name="983489" id="983489">а) устранение дефектов и недоделок, установленных приемочной комиссией;</div></div><div class="ACT_TEXT"><div name="983490" id="983490">б) испытания оборудования для определения надежности работы установок на полную мощность и проверка соответствия их гарантийным и проектным данным.</div></div><div class="ACT_TEXT"><div name="983491" id="983491">119. По окончании строительства или реконструкции тепловые сети и теплоиспользующие установки должны быть приняты в эксплуатацию в соответствии с требованиями ШНК «Приемка в эксплуатацию законченных строительством объектов. Основные положения» и отраслевыми правилами приемки.</div></div><div class="ACT_TEXT"><div name="983492" id="983492">120. Перед вводом в эксплуатацию теплоиспользующих установок и тепловых сетей, после завершения строительно-монтажных работ на них должны быть выполнены предусмотренные строительными нормами и правилами индивидуальные испытания и комплексное опробование.</div></div><div class="ACT_TEXT"><div name="983493" id="983493">121. Индивидуальные испытания систем горячего водоснабжения, отопления, вентиляции проводятся в соответствии с требованиями КМК «Внутренние санитарно-технические системы», тепловых сетей — по указаниям КМК «Тепловые сети», технологических теплоиспользующих установок — в соответствии с требованиями КМК «Технологическое оборудование и технологические трубопроводы».</div></div><div class="ACT_TEXT"><div name="983495" id="983495">122. При комплексном опробовании должна быть проверена совместная работа основных агрегатов и их вспомогательного оборудования под нагрузкой.</div></div><div class="ACT_TEXT"><div name="983496" id="983496">Комплексное опробование технологических теплоиспользующих установок считается проведенным при условии работы под нагрузкой и вывода на устойчивый проектный технологический режим, обеспечивающий выпуск первой партии продукции в объеме, установленном для начального периода освоения проектной мощности. Продолжительность комплексного опробования определяется отраслевыми правилами приемки.</div></div><div class="ACT_TEXT"><div name="983500" id="983500">Комплексное опробование тепловых сетей считается проведенным при условии непрерывной и нормальной работы оборудования в течение 24 ч с номинальным давлением, предусмотренным проектом.</div></div><div class="ACT_TEXT"><div name="983502" id="983502">При вводе в эксплуатацию зданий, цехов (в том числе имеющихся в них отопительно-вентиляционных теплоиспользующих установок), а также питающих эти здания и цеха тепловых сетей в межотопительный период допускается перенос сроков комплексного опробования систем теплопотребления и тепловых сетей на начало отопительного сезона.</div></div><div class="ACT_TEXT"><div name="983503" id="983503">123. До начала приемочных испытаний теплоиспользующих установок и тепловых сетей должен быть укомплектован, подготовлен и аттестован персонал, а также назначены лица, ответственные за исправное состояние и безопасную эксплуатацию теплоиспользующих установок и тепловых сетей. Порядок подготовки и аттестации персонала указан в <a href="/acts/973665#982886">параграфе 3</a> главы II настоящих Правил.</div></div><div class="BY_DEFAULT"><div name="1745893" id="1745893"></div></div><div class="ACT_TEXT"><div name="1745895" id="1745895">124. До ввода в эксплуатацию все трубопроводы, на которые распространяется действие правил Государственной инспекции «Саноатгеоконтехназорат», в зависимости от их категории, должны быть зарегистрированы в региональных инспекциях Государственной инспекции «Саноатгеоконтехназорат» или на предприятии — владельце трубопровода.</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745896" id="1745896">(пункт 124 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745312">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="983505" id="983505">125. Подключение систем теплопотребления к источникам тепловой энергии должно производиться в соответствии с «<a href="/acts/486520#490788">Правилами </a>пользования тепловой энергией».</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983506" id="983506">§ 9. Организационная структура и управление теплоиспользующими установками и тепловыми сетями</div></div><div class="ACT_TEXT"><div name="983507" id="983507">126. На каждом предприятии должно быть организовано круглосуточное управление режимами работы теплоиспользующих установок и тепловых сетей, задачами которого являются:</div></div><div class="ACT_TEXT"><div name="983508" id="983508">ведение заданных режимов работы;</div></div><div class="ACT_TEXT"><div name="983509" id="983509">локализация и ликвидация отказов и нарушений в работе и восстановление режимов работы;</div></div><div class="ACT_TEXT"><div name="983510" id="983510">производство переключений, пусков и остановок; подготовка рабочих мест к ремонтным работам.</div></div><div class="ACT_TEXT"><div name="983511" id="983511">127. Структура управления теплоиспользующими установками и тепловыми сетями определяется руководством предприятия, исходя из местных условий. При этом должны быть предусмотрены распределение функций оперативного контроля и управления между отдельными уровнями управления, а также подчиненность ниже стоящих уровней управления вышестоящим.</div></div><div class="ACT_TEXT"><div name="983512" id="983512">128. Управление теплоиспользующими установками и тепловыми сетями предприятия должно иметь два уровня (две категории): оперативное управление и оперативное ведение.</div></div><div class="ACT_TEXT"><div name="983513" id="983513">В оперативном управлении дежурного (диспетчера) по предприятию должны находиться теплоиспользующие установки и тепловые сети, при операциях с которыми требуется координация действий подчиненного дежурного персонала. Операции с указанными установками и тепловыми сетями должны производиться только под руководством дежурного (диспетчера) по предприятию.</div></div><div class="ACT_TEXT"><div name="983514" id="983514">В оперативном ведении дежурного (диспетчера) по предприятию должны находиться теплоиспользующие установки и отдельные тепловые сети, состояние и режим работы которых влияют на режим и надежность работы тепловых сетей предприятия. Операции с указанными установками должны производиться с разрешения дежурного (диспетчера) по предприятию.</div></div><div class="ACT_TEXT"><div name="983515" id="983515">129. Все теплоиспользующие установки и тепловые сети должны быть распределены руководителем (или главным энергетиком) предприятия по уровням управления. Взаимоотношения специалистов различных уровней управления должны регламентироваться местными инструкциями, согласованными в установленном порядке.</div></div><div class="ACT_TEXT"><div name="983516" id="983516">На предприятии должен быть составлен и утвержден руководителем (или главным инженером) список лиц, имеющих право ведения оперативных переговоров с энергоснабжающей организацией, который необходимо сообщить энергоснабжающей организации.</div></div><div class="ACT_TEXT"><div name="983517" id="983517">130. Теплоиспользующими установками и тепловыми сетями должен управлять оперативный дежурный или оперативно-ремонтный персонал. Помещение (рабочее место) дежурного должно быть обеспечено средствами связи, технической документацией, противопожарным инвентарем, инструментом, запасными частями и материалами.</div></div><div class="ACT_TEXT"><div name="983518" id="983518">131. В случаях, когда требуется немедленное отключение теплоиспользующих установок или тепловых сетей, оно должно быть произведено дежурным или работником из оперативно-ремонтного персонала в соответствии с требованиями производственных инструкций с предварительным, если это возможно, или последующим уведомлением вышестоящего дежурного.</div></div><div class="ACT_TEXT"><div name="983519" id="983519">132. Все переключения в тепловых схемах теплоиспользующих установок и тепловых сетях должны производиться в соответствии с инструкцией по эксплуатации. Сложные переключения, а также переключения, которые необходимо проводить двум исполнителям и более, должны выполняться по программам (бланкам) переключений. Перечень сложных переключений в тепловых схемах теплоиспользующих установок и тепловых сетях, а также список лиц, имеющих право контролировать выполнение этих переключений, должны быть утверждены руководителем (или главным инженером) предприятия.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983520" id="983520">§ 10. Пожарная безопасность</div></div><div class="ACT_TEXT"><div name="983521" id="983521">133. Устройство, эксплуатация и ремонт теплоиспользующих установок и тепловых сетей, зданий и сооружений должны соответствовать требованиям <a href="/acts/722643#723099">Правил</a> пожарной безопасности для энергетических предприятий.</div></div><div class="ACT_TEXT"><div name="983523" id="983523">134. Каждый работник обязан знать и выполнять требования правил пожарной безопасности и не допускать действий, которые могут привести к пожару или загоранию.</div></div><div class="ACT_TEXT"><div name="983528" id="983528">135. Персонал должен проходить противопожарный инструктаж, пополнять знания правил пожарной безопасности при повышении квалификации, участвовать в противопожарных тренировках, проходить периодическую проверку знаний правил пожарной безопасности.</div></div><div class="ACT_TEXT"><div name="983530" id="983530">136. На каждом предприятии должен быть установлен противопожарный режим и выполнены противопожарные мероприятия исходя из особенностей производства и отраслевых норм.</div></div><div class="ACT_TEXT"><div name="983531" id="983531">137. Первичные средства пожаротушения должны эксплуатироваться в соответствии с требованиями правил пожарной безопасности.</div></div><div class="ACT_TEXT"><div name="983533" id="983533">138. Сварочные и другие огнеопасные работы должны проводиться с соблюдением правил пожарной безопасности.</div></div><div class="ACT_TEXT"><div name="983535" id="983535">139. Организация противопожарного режима на предприятиях, ответственность должностных лиц за противопожарный режим, порядок расследования и учета случаев пожара и загорания должны соответствовать отраслевым положениям и инструкциям.</div></div><div class="ACT_TEXT"><div name="983536" id="983536">140. Каждый случай пожара и загорания должен расследоваться для устранения причин, убытков, виновников возникновения пожара и загорания и разработки противопожарных мероприятий.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983539" id="983539">Глава III. Требования к эксплуатации тепловых сетей и теплоиспользующих установок </div></div><div class="TEXT_HEADER_DEFAULT"><div name="983541" id="983541">§ 1. Тепловые сети</div></div><div class="ACT_TEXT"><div name="983543" id="983543">141. Главной задачей эксплуатационного персонала тепловых сетей является бесперебойное снабжение потребителей тепловой энергией в виде горячей воды и пара установленных параметров при минимальных утечках теплоносителя и тепловых потерях.</div></div><div class="ACT_TEXT"><div name="983544" id="983544">142. Все тепловые сети и вводы промышленного предприятия (организации) должны находиться в ведении отдела главного энергетика (механика) предприятия за исключением внутрицеховых сетей, которые, как правило, должны эксплуатироваться цехом, в котором они расположены. Границы участков теплопроводов, разделяемых между цехами (участками), определяются запорной арматурой.</div></div><div class="ACT_TEXT"><div name="983546" id="983546">Распределение теплопроводов между цехами утверждается руководством предприятия.</div></div><div class="ACT_TEXT"><div name="983548" id="983548">Эксплуатация тепловых сетей или участков, не закрепленных за ответственными лицами, запрещается.</div></div><div class="ACT_TEXT"><div name="983550" id="983550">143. Прокладка тепловых сетей, конструкция трубопроводов, тепловая изоляция, строительные конструкции тепловых сетей должны соответствовать требованиям КМК.</div></div><div class="ACT_TEXT"><div name="983552" id="983552">144. По территории предприятий должна предусматриваться надземная прокладка тепловых сетей на отдельно стоящих опорах и эстакадах.</div></div><div class="ACT_TEXT"><div name="983553" id="983553">145. Поверхность земли по всем трассам тепловых сетей должна быть спланирована так, чтобы воспрепятствовать попаданию поверхностных вод в каналы.</div></div><div class="ACT_TEXT"><div name="983555" id="983555">146. Материалы, трубы и арматуру для тепловых сетей следует применять в соответствии с «Правилами устройства и безопасной эксплуатации грузоподъемных кранов».</div></div><div class="ACT_TEXT"><div name="983557" id="983557">147. Все теплопроводы, проложенные в местах, доступных для обслуживания и не имеющие металлической обшивки, должны иметь наружную окраску или цветные концы и подписи согласно <a href="/acts/973665#984009">приложению № 4</a> к настоящим Правилам.</div></div><div class="BY_DEFAULT"><div name="1745898" id="1745898"></div></div><div class="ACT_TEXT"><div name="1745899" id="1745899">148. До ввода в эксплуатацию все трубопроводы, на которые распространяется действие правил Государственной инспекции «Саноатгеоконтехназорат», в зависимости от их категории, должны быть зарегистрированы в региональных инспекциях Государственной инспекции «Саноатгеоконтехназорат» или на предприятии — владельце трубопровода.</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745901" id="1745901">(пункт 148 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745314">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="983561" id="983561">149. Для контроля за состоянием тепловых сетей должен производиться систематический обход всех сетей, камер, проходных каналов, тепловых вводов эксплуатационным персоналом предприятия. Обход производится по графику, утвержденному главным энергетиком (механиком), начальником цеха предприятия, но не реже одного раза в неделю.</div></div><div class="ACT_TEXT"><div name="983563" id="983563">При обходе должны проверяться состояние оборудования, режим работы, плотность сетей, вводов и местных систем. Результаты осмотров должны записываться в журнал обходов.</div></div><div class="ACT_TEXT"><div name="983564" id="983564">Выявленные дефекты должны устраняться немедленно или при ближайшей возможности.</div></div><div class="ACT_TEXT"><div name="983566" id="983566">Дефекты, угрожающие отказом, должны устраняться немедленно. Сведения о дефектах, не угрожающих отказом, которые не могут быть устранены без отключения трубопроводов, должны быть занесены в журнал ремонтов для ликвидации этих дефектов при ближайшем отключении трубопроводов или при ремонте.</div></div><div class="ACT_TEXT"><div name="983567" id="983567">150. Эксплуатация тепловых сетей производится в соответствии с требованиями согласно <a href="/acts/973665#984023">приложению № 5</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983568" id="983568">§ 2. Тепловые пункты</div></div><div class="ACT_TEXT"><div name="983569" id="983569">151. На предприятиях, имеющих собственные источники тепла, тепловой пункт может быть оборудован при котельной или в отдельном помещении, отвечающем требованиям настоящих Правил.</div></div><div class="ACT_TEXT"><div name="983570" id="983570">152. Тепловые пункты предприятий подразделяются на центральные (ЦТП) и индивидуальные (ИТП). </div></div><div class="ACT_TEXT"><div name="983572" id="983572">Строительная часть помещений тепловых пунктов должна соответствовать требованиям КМК.</div></div><div class="ACT_TEXT"><div name="983573" id="983573">Помещение теплового пункта должно быть оборудовано приточно-вытяжной вентиляцией.</div></div><div class="ACT_TEXT"><div name="983575" id="983575">153. Все тепловые пункты, независимо от балансовой принадлежности, должны находиться под контролем теплоснабжающей организации (источника тепловой энергии).</div></div><div class="ACT_TEXT"><div name="983577" id="983577">154. На тепловом пункте должны быть принципиальные схемы паровой и водяной сети, схема сбора и возврата конденсата и инструкции по обслуживанию, установленные нормы расхода теплоносителя, возврата конденсата и режимные графики.</div></div><div class="ACT_TEXT"><div name="983578" id="983578">155. Вся запорная и регулировочная арматура на тепловом пункте должна быть пронумерована согласно схеме.</div></div><div class="ACT_TEXT"><div name="983579" id="983579">Трубопроводы и емкости должны иметь отличительную окраску согласно <a href="/acts/973665#984009">приложению № 4</a> к настоящим Правилам.</div></div><div class="ACT_TEXT"><div name="983580" id="983580">156. Обработка воды для защиты от коррозии и накипеобразования трубопроводов и оборудования систем горячего водоснабжения, присоединенных к тепловым сетям через водоподогреватели, должна проводиться, как правило, в ЦТП. При этом ее качество должно соответствовать санитарным нормам.</div></div><div class="ACT_TEXT"><div name="983581" id="983581">157. Эксплуатация тепловых пунктов должна осуществляться дежурным или оперативно-ремонтным персоналом.</div></div><div class="ACT_TEXT"><div name="983582" id="983582">Необходимость дежурства персонала на тепловом пункте и его продолжительность устанавливаются руководством предприятия в зависимости от местных условий предприятия на основании Трудового <a href="/acts/145261">кодекса </a>Республики Узбекистан.</div></div><div class="ACT_TEXT"><div name="983583" id="983583">158. Тепловые пункты периодически не реже 1 раза в неделю должен осматривать административно-технический персонал предприятия. Результаты осмотра должны быть отражены в оперативном журнале.</div></div><div class="ACT_TEXT"><div name="983584" id="983584">159. Контроль за соблюдением договорных режимов потребления тепловой энергии осуществляется энергоснабжающей организацией и представителем «Узгосэнергонадзор».</div></div><div class="ACT_TEXT"><div name="983586" id="983586">160. Включение и выключение тепловых пунктов, систем теплопотребления и установление расхода теплоносителя производит персонал, обслуживающий тепловые пункты предприятия, с разрешения диспетчера энергоснабжающей организации и под руководством ответственного лица потребителя.</div></div><div class="ACT_TEXT"><div name="983587" id="983587">161. При возникновении аварийной ситуации в тепловых сетях и системах теплопотребления предприятия дежурный по предприятию должен известить диспетчера энергоснабжающей организации и принять меры к локализации и ликвидации нарушений в работе.</div></div><div class="ACT_TEXT"><div name="983588" id="983588">162. Измерительные системы с автоматической обработкой результатов измерений подлежат обязательной сертификации. </div></div><div class="ACT_TEXT"><div name="983590" id="983590">163. Эксплуатация тепловых пунктов производится в соответствии с требованиями согласно <a href="/acts/973665#985197">приложению № 6</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983591" id="983591">§ 3. Баки-аккумуляторы</div></div><div class="ACT_TEXT"><div name="983594" id="983594">164. Баки-аккумуляторы должны изготовляться по специально разработанным проектам.</div></div><div class="ACT_TEXT"><div name="983596" id="983596">На всех вновь вводимых и эксплуатируемых баках-аккумуляторах должны быть установлены наружные усиливающие конструкции для предотвращения разрушения баков.</div></div><div class="ACT_TEXT"><div name="983598" id="983598">165. Рабочий объем баков-аккумуляторов, их расположение на источниках теплоты, в тепловых сетях должны соответствовать КМК «Внутренний водопровод и канализация зданий».</div></div><div class="ACT_TEXT"><div name="983600" id="983600">166. Применение типовых баков хранения нефтепродуктов для замены существующих баков-аккумуляторов запрещается.</div></div><div class="ACT_TEXT"><div name="983602" id="983602">167. Антикоррозийная защита баков-аккумуляторов должна быть выполнена в соответствии с «Методические указания по защите баков-аккумуляторов от коррозии и воды в них от аэрации».</div></div><div class="ACT_TEXT"><div name="983604" id="983604">168. Помещения, в которых устанавливаются баки-аккумуляторы, должны вентилироваться и освещаться. Несущие конструкции помещения должны быть из несгораемых материалов. Под баками необходимо предусматривать поддоны.</div></div><div class="ACT_TEXT"><div name="983606" id="983606">169. Группа баков или отдельно стоящий бак должны быть ограждены земляным валом высотой не менее 0,5 м и шириной по верху не менее 0,5 м, а вокруг бака должна быть выполнена отмостка. В пространстве между баками и ограждением должен быть организован отвод воды в систему канализации. Вокруг баков, расположенных вне территории источника теплоты или предприятия, должно быть предусмотрено ограждение высотой не менее 2,5 м и установлены запрещающие знаки.</div></div><div class="ACT_TEXT"><div name="983607" id="983607">170. До ввода в эксплуатацию, после окончания монтажа или ремонта баков-аккумуляторов должны быть проведены их испытания с учетом требований КМК «Металлоконструкции. Правила производства и приема». Каждый принятый в эксплуатацию бак должен иметь паспорт.</div></div><div class="ACT_TEXT"><div name="983609" id="983609">171. Лицам, не имеющим непосредственного отношения к эксплуатации баков-аккумуляторов, запрещается быть в охранной зоне баков.</div></div><div class="ACT_TEXT"><div name="983611" id="983611">172. Определение состояния баков-аккумуляторов и заключение об их пригодности к дальнейшей эксплуатации должны выполняться ежегодно при отключенном баке путем визуального осмотра его конструкций, основания, компенсирующих устройств подводящих и отводящих трубопроводов, вестовых труб и по результатам осмотра составляется акт, который подписывает ответственный за эксплуатацию бака.</div></div><div class="ACT_TEXT"><div name="983613" id="983613">Осмотр баков, защищенных от коррозии герметиком, производится при замене последнего.</div></div><div class="ACT_TEXT"><div name="983615" id="983615">173. Вокруг баков-аккумуляторов должны быть установлены охранная зона и знаки, запрещающие нахождение в данной зоне лиц, не имеющих непосредственного отношения к эксплуатации баков.</div></div><div class="ACT_TEXT"><div name="983617" id="983617">174. Эксплуатация баков-аккумуляторов производится в соответствии с требованиями согласно <a href="/acts/973665#985285">приложению № 7</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983618" id="983618">§ 4. Водоподогревательные установки</div></div><div class="ACT_TEXT"><div name="983620" id="983620">175. Для каждого водоподогревателя на основе проектных данных и испытаний должна быть установлена техническая характеристика со следующими показателями:</div></div><div class="ACT_TEXT"><div name="983621" id="983621">а) тепловая производительность и соответствующие ей параметры теплоносителя;</div></div><div class="ACT_TEXT"><div name="983622" id="983622">б) максимальная температура нагреваемой воды;</div></div><div class="ACT_TEXT"><div name="983625" id="983625">в) номинальный расход теплоносителей;</div></div><div class="ACT_TEXT"><div name="983627" id="983627">г) предельно допустимое давление со стороны первичного и вторичного теплоносителей.</div></div><div class="ACT_TEXT"><div name="983628" id="983628">176. В системе горячего водоснабжения (по открытой или закрытой схеме) качество воды должно соответствовать санитарным нормам.</div></div><div class="ACT_TEXT"><div name="983630" id="983630">На технологические цели качество воды должно быть таким, чтобы была обеспечена нормальная эксплуатация водоподогревательной установки.</div></div><div class="ACT_TEXT"><div name="983632" id="983632">При неудовлетворительном качестве воды должна предусматриваться дополнительная обработка путем установки осветительных фильтров, водомягчителей и др.</div></div><div class="ACT_TEXT"><div name="983634" id="983634">177. Эксплуатация водоподогревательных установок производится в соответствии с требованиями согласно <a href="/acts/973665#985333">приложению № 8</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983635" id="983635">§ 5. Система сбора и возврата конденсата</div></div><div class="ACT_TEXT"><div name="983636" id="983636">178. У потребителей тепловой энергии, имеющих пароиспользующие установки, должна быть закрытая система сбора и возврата конденсата, а также организован контроль за его качеством.</div></div><div class="ACT_TEXT"><div name="983638" id="983638">Избыточное давление в сборных баках конденсата должно быть не менее 0,005 МПа (0,05 кгс/см<sup>2</sup>). Открытые системы сбора и возврата конденсата допускаются при количестве возвращаемого конденсата менее 10 т/ч и расстоянии от источника теплоты до 0,5 км. Освобождение от возврата конденсата возможно при наличии согласованного с инспекцией «Узгосэнергонадзор» технико-экономическим обоснованием, нецелесообразном возврате, но при полном его использовании на производственные нужды.</div></div><div class="ACT_TEXT"><div name="983646" id="983646">179. Системы сбора и возврата конденсата должны использовать теплоту конденсата для собственных нужд предприятия.</div></div><div class="ACT_TEXT"><div name="983647" id="983647">180. Для увеличения возврата конденсата промпредприятием должны быть проведены следующие основные мероприятия:</div></div><div class="ACT_TEXT"><div name="983649" id="983649">а) установка наиболее эффективных конденсатоотводчиков у пароиспользующих аппаратов и в нижних точках паропроводов; для отвода конденсата с постоянно действующих дренажей паропроводов и спутников последние должны быть соединены с попутными конденсатопроводами;</div></div><div class="ACT_TEXT"><div name="983651" id="983651">б) замена смешивающих подогревателей поверхностными;</div></div><div class="ACT_TEXT"><div name="983652" id="983652">в) максимальное использование тепла пролетного пара и пара вторичного вскипания путем установки теплообменников, сепараторов, термокомпрессоров и т. п.;</div></div><div class="ACT_TEXT"><div name="983653" id="983653">г) перевод парового привода на электрический;</div></div><div class="ACT_TEXT"><div name="983655" id="983655">д) очистка конденсата от масла и других примесей;</div></div><div class="ACT_TEXT"><div name="983656" id="983656">е) максимальное сокращение потребления конденсата на технологические или другие нужды;</div></div><div class="ACT_TEXT"><div name="983657" id="983657">ж) организация постоянного контроля за качеством производственного конденсата.</div></div><div class="ACT_TEXT"><div name="983658" id="983658">Теплоснабжающая организация вправе предлагать потребителю тепловой энергии перечень таких мероприятий и определять совместно с ним сроки их выполнения.</div></div><div class="ACT_TEXT"><div name="983659" id="983659">181. Количество конденсата, возвращаемого на собственные источники теплоты, устанавливается на основе проекта или пароконденсатного баланса предприятия. Для предприятий, получающих пар от сторонних источников теплоты, норма возврата конденсата (в процентах от количества потребляемого пара) и его количество устанавливается по проекту пароконденсатному балансу, и фиксируются в договоре на использование тепловой энергией. Договорная норма возврата конденсата должна ежегодно пересматриваться с учетом результатов внедрения мероприятий, направленных на увеличение количества возвращаемого конденсата.</div></div><div class="ACT_TEXT"><div name="983660" id="983660">182. Периодически, но не реже одного раза в 6 месяцев, все конденсатоотводчики должны подвергаться ревизии.</div></div><div class="ACT_TEXT"><div name="983661" id="983661">Должна также контролироваться плотность обратных клапанов в сроки, установленные местной инструкцией.</div></div><div class="ACT_TEXT"><div name="983662" id="983662">На предприятиях должен быть установлен постоянно действующий стенд для проверки и наладки работы конденсатоотводчиков.</div></div><div class="ACT_TEXT"><div name="983663" id="983663">183. Капитальный ремонт оборудования систем сбора и возврата конденсата (трубопроводов, арматуры, баков, насосов, электродвигателей и пр.), работающих в течение года без сезонного перерыва, должен производиться не реже 1 раза в 2 года.</div></div><div class="ACT_TEXT"><div name="983664" id="983664">Установки, работающие с перерывами, ремонтируются ежегодно. Текущий ремонт производится не реже 1 раза в год.</div></div><div class="ACT_TEXT"><div name="983666" id="983666">Ремонт оборудования системы сбора и возврата конденсата должен совместиться с ремонтом соответствующих теплоприемников и оборудования источника теплоснабжения.</div></div><div class="ACT_TEXT"><div name="983669" id="983669">184. Эксплуатация системы сбора и возврата конденсата производится в соответствии с требованиями согласно <a href="/acts/973665#985357">приложению № 9</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983673" id="983673">§ 6. Теплоиспользующие установки</div></div><div class="ACT_TEXT"><div name="983675" id="983675">185. Конструирование каждой теплоиспользующей установки должно производиться с учетом внедрения передовых энергосберегающих, экологически чистых технологий, максимально исключающих выход вторичных энергоресурсов. При этом образующиеся вторичные энергоресурсы должны быть максимально использованы в пределах технических возможностей и экономической эффективности.</div></div><div class="ACT_TEXT"><div name="983677" id="983677">Теплоутилизационное устройство может предусматриваться на группу теплоиспользующих установок. Количество теплоутилизационных устройств определяется режимом работы технологических теплоиспользующих установок. Отказ от применения вторичных энергоресурсов должен быть обоснован технико-экономическим расчетом.</div></div><div class="ACT_TEXT"><div name="983678" id="983678">При проектировании и строительстве новых систем вентиляции, а также их реконструкции должно предусматриваться использование теплоты вентиляционных выбросов.</div></div><div class="ACT_TEXT"><div name="983680" id="983680">186. Конструкция теплоиспользующих установок должна быть надежной, обеспечивать безопасность эксплуатации, возможность осмотра, очистки, промывки, продувки и ремонта.</div></div><div class="ACT_TEXT"><div name="983681" id="983681">187. Теплоиспользующая установка, трубопроводы и вспомогательное оборудование к ней должны быть в соответствии с <a href="/acts/973665#984009">приложением № 4</a> настоящих Правил окрашены лаками или красками, стойкими против паров и газов, выделяющихся в помещении, где расположена данная установка. Окраска должна производиться не реже одного раза в 2 года.</div></div><div class="BY_DEFAULT"><div name="1745887" id="1745887"></div></div><div class="ACT_TEXT"><div name="1745889" id="1745889">188. Установки, работающие под давлением, подвергаются наружному, внутреннему осмотрам и гидравлическому испытанию в соответствии с действующими правилами Государственной инспекции «Саноатгеоконтехназорат» и местными эксплуатационными инструкциями.</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745890" id="1745890">(пункт 188 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745310">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="983685" id="983685">189. Запрещается работа теплоиспользующей установки в следующих случаях:</div></div><div class="ACT_TEXT"><div name="983687" id="983687">а) если истек срок освидетельствования установки;</div></div><div class="BY_DEFAULT"><div name="1745903" id="1745903"></div></div><div class="ACT_TEXT"><div name="1745904" id="1745904">б) нет регистрации установки в Государственной инспекции «Саноатгеоконтехназорат» (в случае если установки подлежат регистрации в Государственной инспекции «Саноатгеоконтехназорат»);</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745906" id="1745906">(подпункт «б» пункта 189 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745316">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="983690" id="983690">в) если давление поднимается выше допустимого, несмотря на соблюдение всех требований, указанных в инструкции по обслуживанию;</div></div><div class="ACT_TEXT"><div name="983691" id="983691">г) при неисправности предохранительных клапанов;</div></div><div class="ACT_TEXT"><div name="983692" id="983692">д) при неисправности манометра и невозможности определить давление по другим приборам;</div></div><div class="ACT_TEXT"><div name="983694" id="983694">е) при неисправности или при неполном количестве крепежных деталей крышек и люков;</div></div><div class="ACT_TEXT"><div name="983695" id="983695">ж) при неисправности предохранительных блокировочных устройств;</div></div><div class="ACT_TEXT"><div name="983697" id="983697">з) при неисправности контрольно-измерительных приборов и средств автоматики, предусмотренных проектом;</div></div><div class="ACT_TEXT"><div name="983699" id="983699">и) при отсутствии паспорта.</div></div><div class="ACT_TEXT"><div name="983700" id="983700">190. Обслуживание, ремонт (кроме перемотки электродвигателей) и профилактические испытания электроприводов запорной и регулировочной арматуры, на которые воздействуют автоматические регуляторы, должны производиться персоналом, обслуживающим приборы теплового контроля.</div></div><div class="ACT_TEXT"><div name="983701" id="983701">Обслуживание электроприводов и другой запорно-регулировочной арматуры должно производиться электротехническим персоналом.</div></div><div class="ACT_TEXT"><div name="983702" id="983702">191. Эксплуатация теплоиспользующих установок производится в соответствии с требованиями согласно <a href="/acts/973665#985411">приложению № 10</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983703" id="983703">§ 7. Паровые молоты</div></div><div class="ACT_TEXT"><div name="983704" id="983704">192. При эксплуатации паровых молотов как ковочных, так и штамповочных с весом падающих частей более 250 кг должны руководствоваться требованиями настоящего параграфа.</div></div><div class="ACT_TEXT"><div name="983705" id="983705">193. На каждом предприятии должна быть установлена и утверждена руководителем (или главным инженером) экономически целесообразная схема использования отработанного пара от молотков.</div></div><div class="ACT_TEXT"><div name="983707" id="983707">194. В каждом цехе должен быть организован учет числа часов работы каждого молота, веса поковок по каждому молоту за месяц и за смену, а также определен общий расход пара молотами.</div></div><div class="ACT_TEXT"><div name="983708" id="983708">195. Эксплуатация паровых молотов производится в соответствии с требованиями согласно <a href="/acts/973665#985541">приложению № 11</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983710" id="983710">§ 8. Сушильные установки</div></div><div class="ACT_TEXT"><div name="983711" id="983711">196. При эксплуатации всех сушильных установок (сушилок) непрерывного или периодического действия, работающих при атмосферном давлении или под вакуумом должны руководствоваться требованиями настоящего параграфа.</div></div><div class="ACT_TEXT"><div name="983712" id="983712">197. В заводской или цеховой лаборатории должны быть в наличии электросушильный шкаф, аналитические и технические весы для определения влажности высушиваемого материала и не менее двух эксикаторов.</div></div><div class="ACT_TEXT"><div name="983713" id="983713">198. Эксплуатация сушильных установок производится в соответствии с требованиями согласно <a href="/acts/973665#985581">приложению № 12</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983715" id="983715">§ 9. Выпарные установки</div></div><div class="ACT_TEXT"><div name="983717" id="983717">199. При эксплуатации выпарных установок периодического и непрерывного действия, работающих под давлением или под вакуумом должны руководствоваться требованиями настоящего параграфа.</div></div><div class="ACT_TEXT"><div name="983718" id="983718">200. Эксплуатация выпарных установок производится в соответствии с требованиями согласно <a href="/acts/973665#985581">приложению № 13</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983719" id="983719">§ 10. Ректификационные установки</div></div><div class="ACT_TEXT"><div name="983722" id="983722">201. При эксплуатации ректификационных установок периодического и непрерывного действия, работающих под вакуумом или под давлением, в которых нагрев продуктов производится с помощью поверхностных теплообменников, должны руководствоваться требованиями настоящего параграфа.</div></div><div class="ACT_TEXT"><div name="983723" id="983723">202. В процессе ректификации спирта или других воспламеняющихся продуктов эксплуатация установок должна производиться по специальным инструкциям, составленным в соответствии с правилами противопожарной безопасности.</div></div><div class="ACT_TEXT"><div name="983724" id="983724">203. Эксплуатация ректификационных установок производится в соответствии с требованиями согласно <a href="/acts/973665#985652">приложению № 14</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983727" id="983727">§ 11. Установки для термовлажностной обработки железобетонных изделий</div></div><div class="ACT_TEXT"><div name="983728" id="983728">204. При эксплуатации всех установок для термовлажностной обработки железобетонных изделий, использующих в качестве теплоносителя пар или горячую воду и работающих при избыточном атмосферном давлении или под вакуумом должны руководствоваться требованиями настоящего параграфа.</div></div><div class="ACT_TEXT"><div name="983729" id="983729">205. Для каждой установки должна быть разработана технологическая инструкция, включающая тепловую схему, разработаны удельные нормы расхода теплоэнергии и обеспечен контроль за их выполнением.</div></div><div class="ACT_TEXT"><div name="983731" id="983731">206. Эксплуатация установок для термовлажностной обработки железобетонных изделий производится в соответствии с требованиями согласно <a href="/acts/973665#985684">приложению № 15</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983733" id="983733">§ 12. Системы отопления, вентиляции и горячего водоснабжения</div></div><div class="ACT_TEXT"><div name="983734" id="983734">207. При реконструкции или расширении предприятий, здания которых имеют паровые системы отопления, вентиляции и горячего водоснабжения, должна проверяться экономическая целесообразность перевода существующих систем с пара на горячую воду.</div></div><div class="ACT_TEXT"><div name="983735" id="983735">208. Трубопроводы и отопительные приборы необходимо окрашивать масляной краской. В помещениях, где имеется выделение паров или газов, окисляющих железо, окраска должна быть кислотоупорной; в помещениях с повышенной влажностью все трубопроводы и приборы отопления должны быть покрыты масляной краской дважды.</div></div><div class="ACT_TEXT"><div name="983736" id="983736">209. Все теплопроводы и арматура, находящиеся в не отапливаемых помещениях, должны быть изолированы.</div></div><div class="ACT_TEXT"><div name="983737" id="983737">210. К отопительным приборам должен быть обеспечен свободный доступ.</div></div><div class="ACT_TEXT"><div name="983738" id="983738">Арматура должна устанавливаться в местах, доступных для обслуживания и ремонта.</div></div><div class="ACT_TEXT"><div name="983739" id="983739">211. Дефекты, обнаруженные в процессе эксплуатации и при осмотре системы отопления, должны быть записаны в ведомости дефектов и учтены при составлении плана ремонтных работ. Дефекты, не требующие опорожнения системы, должны ликвидироваться немедленно.</div></div><div class="ACT_TEXT"><div name="983740" id="983740">212. График текущего и капитального ремонтов отопительных систем должен быть согласован с графиком ремонта отапливаемых помещений и предусматривать полное окончание всех работ не позднее чем за 15 дней до начала отопительного сезона.</div></div><div class="ACT_TEXT"><div name="983741" id="983741">213. Эксплуатация систем отопления, вентиляции и горячего водоснабжения производится в соответствии с требованиями согласно <a href="/acts/973665#985729">приложению № 16</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983742" id="983742">§ 13. Агрегаты воздушного отопления и системы вентиляции</div></div><div class="ACT_TEXT"><div name="983743" id="983743">214. При эксплуатации всех агрегатов воздушного отопления и системы вентиляции промышленных предприятий и организаций должны руководствоваться требованиями настоящего параграфа.</div></div><div class="ACT_TEXT"><div name="983813" id="983813">215. Для технического руководства эксплуатацией отопительно-вентиляционных установок на промышленных предприятиях, в зависимости от размера вентиляционного хозяйства, в отделе главного энергетика (механика) должно быть создано бюро по вентиляции или выделен ответственный специалист. Ответственным за эксплуатацию вентиляционных установок в цехе, как правило, является начальник цеха.</div></div><div class="ACT_TEXT"><div name="983814" id="983814">Начальник цеха обязан контролировать исправность вентиляционных установок.</div></div><div class="ACT_TEXT"><div name="983815" id="983815">216. Начальник смены является ответственным за эксплуатацию вентиляционных установок в своей смене. В случае аварии или других причин, вызывающих остановку действия вентиляции в цехе, он обязан подтверждать своей подписью в журнале эксплуатации причину и продолжительность перерыва в работе вентиляционных установок.</div></div><div class="ACT_TEXT"><div name="983816" id="983816">217. На каждую приточную вентиляционную установку и систему воздушного отопления должен быть составлен паспорт с технической характеристикой и схемой установки.</div></div><div class="ACT_TEXT"><div name="983817" id="983817">Изменения, произведенные в установках, а также результаты испытаний должны фиксироваться в журнале эксплуатации и в паспорте.</div></div><div class="ACT_TEXT"><div name="983818" id="983818">218. Не реже 1 раза в неделю эксплуатационный персонал должен производить тщательный осмотр оборудования систем воздушного отопления и вентиляции с проверкой соответствия притока и вытяжки заданному режиму, положения заслонок, подогрева воздуха в калориферах, состояния теплопроводов и т. д.</div></div><div class="ACT_TEXT"><div name="983819" id="983819">Обход установок дежурными слесарями должен производиться ежедневно.</div></div><div class="ACT_TEXT"><div name="983820" id="983820">219. Ремонт вентиляционных установок, связанных с технологическим процессом, производится одновременно с ремонтом технологического оборудования.</div></div><div class="ACT_TEXT"><div name="983821" id="983821">220. Эксплуатация агрегатов воздушного отопления и систем вентиляции производится в соответствии с требованиями согласно <a href="/acts/973665#985862">приложению № 17</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983822" id="983822">§ 14. Теплообменные аппараты</div></div><div class="ACT_TEXT"><div name="983823" id="983823">221. При эксплуатации теплообменных аппаратов рекуперативного действия поверхностного типа, в которых теплоносителями являются водяной пар или горячая вода должны руководствоваться требованиями настоящего параграфа.</div></div><div class="ACT_TEXT"><div name="983824" id="983824">222. Эксплуатация теплообменных аппаратов производится в соответствии с требованиями согласно <a href="/acts/973665#985910">приложению № 18</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983825" id="983825">§ 15. Теплоизмерительные приборы и автоматические регуляторы тепловых процессов </div></div><div class="ACT_TEXT"><div name="983826" id="983826">223. При эксплуатации всех теплоизмерительных приборов и автоматических регуляторов тепловых процессов, обеспечивающих правильность ведения технологического режима, безопасную работу оборудования и учет тепловой энергии должны руководствоваться требованиями настоящего параграфа.</div></div><div class="ACT_TEXT"><div name="983827" id="983827">224. Эксплуатация теплоизмерительных приборов на предприятиях должна осуществляться в соответствии с <a href="/acts/99874">Законом </a>Республики Узбекистан «О метрологии». </div></div><div class="ACT_TEXT"><div name="983828" id="983828">Измерительные средства тепловой энергии должны пройти метрологическую поверку в агентстве «Узстандарт» в порядке, установленном законодательством.</div></div><div class="ACT_TEXT"><div name="983829" id="983829">225. Основной задачей органов метрологической службы предприятий и организаций являются обеспечение постоянной верности, исправного состояния, правильного применения и хранения измерительной техники, находящейся в эксплуатации.</div></div><div class="ACT_TEXT"><div name="983830" id="983830">226. Органами метрологической службы, осуществляющими надзор за приборами теплотехнического контроля, являются службы тепловой автоматики и измерений (цех, лаборатория) предприятий и организаций, которые должны иметь регистрационные удостоверения агентства «Узстандарт»;</div></div><div class="ACT_TEXT"><div name="983831" id="983831">В объем работ лаборатории или цеха теплового контроля и автоматики входят:</div></div><div class="ACT_TEXT"><div name="983832" id="983832">а) разработка калибровочных схем и состояние графиков калибровок измерительной техники, согласование их с агентством «Узстандарт» и представление на утверждение руководству предприятия;</div></div><div class="ACT_TEXT"><div name="983834" id="983834">б) проведение в установленные сроки калибровок приборов и своевременное представление измерительной техники на Государственную поверку в агентство «Узстандарт»;</div></div><div class="ACT_TEXT"><div name="983835" id="983835">в) организация и осуществление ремонта, юстировки и наладки измерительной техники;</div></div><div class="ACT_TEXT"><div name="983836" id="983836">г) контроль правильности монтажа измерительной техники в целях обеспечения должной точности и надежности ее работы;</div></div><div class="ACT_TEXT"><div name="983837" id="983837">д) участие в выявлении причин брака в работе и других потерь, являющихся следствием применения несовершенной или неверной измерительной техники, а также в разработке и проведении мероприятий по предупреждению и устранению этих потерь;</div></div><div class="ACT_TEXT"><div name="983838" id="983838">е) организация подготовки и повышения квалификации своих работников и участие в проведении мероприятий по повышению квалификации лиц, непосредственно пользующихся измерительной техникой;</div></div><div class="ACT_TEXT"><div name="983839" id="983839">ж) ведение учета имеющейся измерительной техники, выявление потребности и составление заявок на недостающие средства измерений, перераспределение измерительной техники внутри предприятия;</div></div><div class="ACT_TEXT"><div name="983840" id="983840">з) контроль за установкой, снятием диаграмм с регистрирующих приборов и обработкой записей показаний.</div></div><div class="ACT_TEXT"><div name="983841" id="983841">227. На предприятиях, не имеющих специальных подразделений метрологической службы, на лицо, ответственное за измерительное хозяйство, возлагается:</div></div><div class="ACT_TEXT"><div name="983842" id="983842">а) контроль за правильным применением и хранением измерительной техники;</div></div><div class="ACT_TEXT"><div name="983843" id="983843">б) составление графиков поверок измерительной техники, находящейся в эксплуатации, согласование их с агентством «Узстандарт» и представление на утверждение руководству предприятия;</div></div><div class="ACT_TEXT"><div name="983844" id="983844">в) представление измерительной техники на государственную поверку и в ремонт;</div></div><div class="ACT_TEXT"><div name="983845" id="983845">г) принудительное изъятие из применения измерительной техники, не отвечающей техническим требованиям и используемой не по назначению.</div></div><div class="ACT_TEXT"><div name="983846" id="983846">228. Поверка измерительной техники должна производиться в полном соответствии с КМК, инструкциями и методическими указаниями агентства «Узстандарт».</div></div><div class="ACT_TEXT"><div name="983847" id="983847">Поверка измерительной техники, на которую отсутствуют государственные стандарты, инструкции и методические указания агентства «Узстандарт», производится по временным методикам, утвержденным вышестоящим органом метрологической службы.</div></div><div class="ACT_TEXT"><div name="983848" id="983848">229. Оформление результатов поверки измерительной техники, признанной при поверке годной, производится органами метрологической службы предприятий и организаций путем отметки в паспортах, нанесения установленных знаков (клейм), выдачи аттестатов или другими согласованными с местными органами агентства «Узстандарт».</div></div><div class="ACT_TEXT"><div name="983849" id="983849">230. На всех предприятиях и ведомствах могут применяться лишь меры и измерительные приборы, разрешаемые к применению агентством «Узстандарт».</div></div><div class="ACT_TEXT"><div name="983850" id="983850">Применение других мер и измерительных приборов отраслевого назначения допускается только с разрешения вышестоящего органа метрологической службы.</div></div><div class="ACT_TEXT"><div name="983851" id="983851">231. Поверка измерительной техники производится лицами, прошедшими специальную метрологическую подготовку и аттестованными Комиссиями, назначаемыми руководителями предприятий и организаций с обязательным участием представителей местных органов агентства «Узстандарт».</div></div><div class="ACT_TEXT"><div name="983853" id="983853">232. На все теплоизмерительные приборы должны быть составлены паспорта с отметками и заключениями о государственных и периодических поверках.</div></div><div class="ACT_TEXT"><div name="983854" id="983854">Если при пользовании прибором необходимо введение поправок по результатам поверки, выписывается аттестат с поправками к показаниям прибора.</div></div><div class="ACT_TEXT"><div name="983855" id="983855">Лаборатория теплового контроля и автоматики должна вести журналы для записи результатов всех произведенных поверок и ремонтов приборов и автоматических регуляторов.</div></div><div class="ACT_TEXT"><div name="983856" id="983856">233. Ответственность за сохранность и внешнее состояние приборов и автоматических регуляторов несет персонал цехов, в которых они установлены.</div></div><div class="ACT_TEXT"><div name="983857" id="983857">234. Для измерения температуры, расхода, давления, уровня, солесодержания, и разрежения должны применяться приборы, отвечающие пределу измеряемого теплоносителя и установленному классу точности в соответствии с Руководящими документами Республики Узбекистан.</div></div><div class="ACT_TEXT"><div name="983858" id="983858">235. При получении тепловой энергии от системы ГАК «Узбекэнерго» установка расчетных контрольно-измерительных приборов регламентируется <a href="/acts/486520#490788">Правилами </a>пользования тепловой энергией.</div></div><div class="ACT_TEXT"><div name="983859" id="983859">236. Объем контрольно-измерительных приборов и средств автоматизации для теплоиспользующих установок и тепловых сетей указан в соответствующих главах настоящих Правил.</div></div><div class="ACT_TEXT"><div name="983860" id="983860">237. Задачи автоматизации систем диспетчерского и технологического управления теплоиспользующими установками и тепловыми сетями должны решаться в комплексе работ по автоматизации технологического процесса предприятия.</div></div><div class="ACT_TEXT"><div name="983861" id="983861">238. Эксплуатация теплоизмерительных приборов и автоматических регуляторов тепловых процессов производится в соответствии с требованиями согласно <a href="/acts/973665#985936">приложению № 19</a> к настоящим Правилам.</div></div><div class="TEXT_HEADER_DEFAULT"><div name="983862" id="983862">Глава IV. Заключительное положение</div></div><div class="ACT_TEXT"><div name="983863" id="983863">239. Настоящие Правила согласованы с Государственной акционерной компанией «Узбекэнерго», агентствами «Узстандарт», «Узкоммунхизмат», Государственной инспекцией «Саноатконтехназорат», Производственным объединением «Таштеплоэнерго», Открытым акционерным обществом «Теплоэлектропроект».</div></div><div class="SIGNATURE"><div name="983864" id="983864">Председатель правления ГАК «Узбекэнерго» Э. ШОИСМАТОВ</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983865" id="983865">г. Ташкент,</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983866" id="983866">16 декабря 2005 г.</div></div><div class="SIGNATURE"><div name="983867" id="983867">Генеральный директор агентства «Узстандарт» Р. БУРИЕВ</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983869" id="983869">г. Ташкент,</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983870" id="983870">7 декабря 2005 г.</div></div><div class="SIGNATURE"><div name="983872" id="983872">Генеральный директор агентства «Узкоммунхизмат» У. ХАЛМУХАМЕДОВ </div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983874" id="983874">г. Ташкент,</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983875" id="983875">1 декабря 2005 г.</div></div><div class="SIGNATURE"><div name="983910" id="983910">Начальник Государственной инспекции «Саноатконтехназорат» Р. САИДОВ </div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983912" id="983912">г. Ташкент,</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983914" id="983914">13 декабря 2005 г.</div></div><div class="SIGNATURE"><div name="983915" id="983915">Генеральный директор ПО «Таштеплоэнерго» Т. АНВАРОВ</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983918" id="983918">г. Ташкент,</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983919" id="983919">12 декабря 2005 г.</div></div><div class="SIGNATURE"><div name="983921" id="983921">Председатель правления ОАО «Теплоэлектропроект» Г. ФЕДОРИН</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983922" id="983922">г. Ташкент,</div></div><div class="ACT_ESSENTIAL_ELEMENTS"><div name="983923" id="983923">6 декабря 2005 г.</div></div><div class="BY_DEFAULT"><div name="983935" id="983935"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="983939" id="983939">ПРИЛОЖЕНИЕ № 1<br /> (форма журнала) к <a href="/acts/973665#982707">Правилам </a>технической эксплуатации<br /> теплоиспользующих установок и тепловых сетей </div></div><div class="BY_DEFAULT"><div name="983941" id="983941"></div></div><div class="TABLE_STD" id="theDefCssID"><div name="983950" id="983950" class="tabBox"><table id="theTableID" style="PADDING-RIGHT: 0px; ; PADDING-LEFT: 0px; LEFT: 2px; PADDING-BOTTOM: 0px; WIDTH: 100%; BORDER-TOP-STYLE: none; PADDING-TOP: 0px; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TOP: 0px; BORDER-BOTTOM-STYLE: none" cellspacing="1" cols="7" border="1">
<colgroup>
<col />
<col />
<col />
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<td style="WIDTH: 41px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 172px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 90px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 103px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="7">
<p align="center"><strong><font size="2">Ж У Р Н А Л‎‎</font></strong></p></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="7">
<p align="center"><strong><font size="2">‎‎проверки знаний ПТЭ и ПТБ технологического персонала</font></strong></p></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="7">
<p align="center"><font size="2">‎‎Предприятие ________________________________________________________</font></p></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="7">
<p align="center"><font size="2">‎‎Цех (отдел) __________________________________________________________</font></p></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td>
<p align="center"><font size="2">№ пп ‎</font></p></td>
<td>
<p align="center"><font size="2">Фамилия, имя и отчество, должность и стаж работы в этой должности ‎</font></p></td>
<td>
<p align="center"><font size="2">Дата предыдущей проверки и оценки ‎</font></p></td>
<td>
<p align="center"><font size="2">Дата и причина проверки‎</font></p></td>
<td>
<p align="center"><font size="2">Общая оценка знаний и заключение‎</font></p></td>
<td>
<p align="center"><font size="2">Подпись проверяемого лица‎</font></p></td>
<td>
<p align="center"><font size="2">Подпись проверяющего лица</font> ‎</p></td></tr>
<tr>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr></tbody></table></div></div><div class="BY_DEFAULT"><div name="983953" id="983953"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="983954" id="983954">ПРИЛОЖЕНИЕ № 2<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации теплоиспользующих <br />установок и тепловых сетей </div></div><div class="BY_DEFAULT"><div name="983957" id="983957"></div></div><div class="TABLE_STD" id="theDefCssID"><div name="983966" id="983966" class="tabBox"><table id="theTableID" style="PADDING-RIGHT: 0px; ; PADDING-LEFT: 0px; LEFT: 2px; PADDING-BOTTOM: 0px; WIDTH: 723px; BORDER-TOP-STYLE: none; PADDING-TOP: 0px; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TOP: 0px; BORDER-BOTTOM-STYLE: none" cellspacing="1" cols="5" border="1">
<colgroup>
<col />
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="2">
<p align="center"><strong><font size="2">‎‎Форма удостоверения о проверке знаний‎‎</font></strong> </p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="2">
<p align="left"><font size="2">‎‎‎‎(печатается на плотной бумаге) ‎‎</font></p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="5"><font size="2">‎‎Организация, предприятие _____________________________________________________________________________</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="3">
<p align="center"><strong><font size="2">‎‎УДОСТОВЕРЕНИЕ №</font></strong></p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="5"><font size="2">‎‎Ф.И.О. _____________________________________________________________________________________________</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="5"><font size="2">‎‎Допущен к обслуживанию в качестве ____________________________________________________________________</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="5"><font size="2">‎‎Основание: Протокол квалификационной комиссии</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="3"><font size="2">‎‎№ _____ от «_____» __________ 20___ г.</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="5"><font size="2">‎‎м. п. _______________ Председатель комиссии ____________________________</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">
<p align="center"><font size="2">‎‎‎(подпись)</font></p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="2"></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">
<p align="center"><font size="2">(На обороте)‎</font></p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="3">
<p align="center"><strong><font size="2">‎‎Результат проверки знаний ПТЭ, ПТБ и инструкции</font></strong></p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">
<p align="center"><font size="2">‎</font></p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">
<p align="center"><font size="2">‎</font></p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">
<p align="center"><font size="2">‎</font></p></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">
<p align="center"><font size="2">‎</font></p></td></tr>
<tr>
<td>
<p align="center"><font size="2">Дата‎</font></p></td>
<td>
<p align="center"><font size="2">Причина проверки‎</font></p></td>
<td>
<p align="center"><font size="2">№ и дата<br />‎ протокола ‎</font></p></td>
<td>
<p align="center"><font size="2">Общая оценка ‎</font></p></td>
<td>
<p align="center"><font size="2">Подпись председателя ‎</font></p></td></tr>
<tr>
<td rowspan="2"><font size="2">‎‏<br />‎</font></td>
<td rowspan="2"><font size="2">‎‏<br />‎</font></td>
<td rowspan="2"><font size="2">‎‏<br />‎</font></td>
<td rowspan="2"><font size="2">‎‏<br />‎</font></td>
<td rowspan="2"><font size="2">‎‏<br />‎</font></td></tr>
<tr><font size="2"></font></tr></tbody>
<caption valign="bottom"><font size="2">‎</font></caption></table></div></div><div class="BY_DEFAULT"><div name="983987" id="983987"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="983988" id="983988">ПРИЛОЖЕНИЕ № 3 к <br /><a href="/acts/973665#982707">Правилам</a> технической эксплуатации теплоиспользующих <br />установок и тепловых сетей </div></div><div class="BY_DEFAULT"><div name="983989" id="983989"></div></div><div class="TABLE_STD" id="theDefCssID"><div name="983992" id="983992" class="tabBox"><table id="theTableID" style="TABLE-LAYOUT: auto; PADDING-RIGHT: 0px; ; PADDING-LEFT: 0px; LEFT: 2px; PADDING-BOTTOM: 0px; WIDTH: 100%; BORDER-TOP-STYLE: none; PADDING-TOP: 0px; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TOP: 0px; BORDER-COLLAPSE: collapse; BORDER-BOTTOM-STYLE: none" cellspacing="1" cols="14" border="1">
<colgroup>
<col />
<col />
<col />
<col />
<col />
<col />
<col />
<col />
<col />
<col />
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<td style="VERTICAL-ALIGN: middle; WIDTH: 79px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 77px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 44px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 26px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="VERTICAL-ALIGN: middle; WIDTH: 88px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 68px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 46px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 40px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 48px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 28px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 32px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 15px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 67px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none" colspan="14">
<p align="center"><strong><font size="2">‎‎Пароконденсатный баланс</font></strong></p></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none" colspan="14">
<p align="center"><font size="2">Предприятие (организация) ______________________________ на 20__ г.</font></p></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="3">‎‏<font size="1"><font size="2">Наименование</font> </font><font size="2">цеха, агрегата‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="3"><font size="1"><font size="2">Характер теплового процесса</font> ‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="3"><font size="2">Число агрегатов‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" colspan="2" rowspan="2">
<p align="center"><font size="2">Проектные параметры по технологии‎‏</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="3"><font size="2">Коэффициент одновременности</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" colspan="3">
<p align="center"><font size="2">Количество потребляемого пара, т/час‎‎</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" colspan="4"><font size="1"><font size="2">‎‎Возврат конденсата<br /></font>‎‎‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="3">
<p align="center"><font size="1"><font size="2">Приме<br />‎чание</font>‎‏</font></p></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="2"><font size="2">одним агрегатом</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" colspan="2">
<p align="center"><font size="2">всеми агрегатами‎</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" colspan="2">
<p align="center"><font size="2">зимой</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" colspan="2"><font size="1"><font size="2">летом</font> ‎‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">кгс/cм</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">0С</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">
<p align="center"><font size="2">зимой‎</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">
<p align="center"><font size="2">летом</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">
<p align="center"><font size="2">т/час</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">
<p align="center"><font size="2">%</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">
<p align="center"><font size="2">т/час</font> </p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">
<p align="center"><font size="2">%</font></p></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td>
<td>‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr></tbody></table></div></div><div class="BY_DEFAULT"><div name="984009" id="984009"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="984010" id="984010">ПРИЛОЖЕНИЕ № 4 к <br /><a href="/acts/973665#982707">Правилам</a> технической эксплуатации теплоиспользующих <br />установок и тепловых сетей </div></div><div class="BY_DEFAULT"><div name="984011" id="984011"></div></div><div class="TABLE_STD" id="theDefCssID"><div name="984017" id="984017" class="tabBox"><table id="theTableID" style="TABLE-LAYOUT: auto; PADDING-RIGHT: 0px; ; PADDING-LEFT: 0px; LEFT: 2px; PADDING-BOTTOM: 0px; WIDTH: 100%; BORDER-TOP-STYLE: none; PADDING-TOP: 0px; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TOP: 0px; BORDER-BOTTOM-STYLE: none" cellspacing="1" cols="4" border="1">
<colgroup>
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none" colspan="4">
<p align="center"><strong><font size="2">Окраска и надписи для трубопроводов</font></strong></p></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="2">
<p align="center"><font size="2">‎‏<br />Наименование теплоносителя‎</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="2">
<p align="center"><font size="2">‎‏<br />Условное обозначение‎</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" colspan="2">
<p align="center"><font size="2">‎‎Цвет краски</font></p></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">
<p align="center"><font size="2">основной‎</font></p></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">
<p align="center"><font size="2">кольца или полоса‎</font></p></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Пар перегретый острый (до 39 кгс/см<sup>2</sup>)‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">П.П. с.д.‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">красный‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">без колец‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Пар насыщенный‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">красный‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">желтый‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Пар отборный и противодавление‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">красный‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">зеленый‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Вода химическая очищенная‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">зеленый‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">белый‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Конденсат‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">зеленый‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">синий‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Дренаж и продувка‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">зеленый‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">красный‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Вода питательная‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">зеленый‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">без колец‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Вода техническая‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">черный‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">без колец‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Водопровод пожарный‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">оранжевый‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">без колец‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Тепловые сети:‎‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">О.С.‎‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">а) подающая линия‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2"></font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">зеленый‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">желтый‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">б) обратная линия</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">зеленый‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">коричневый‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td></tr></tbody></table></div></div><div class="BY_DEFAULT"><div name="984023" id="984023"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="984025" id="984025">ПРИЛОЖЕНИЕ № 5<br /> к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации теплоиспользующих <br />установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="984026" id="984026">Технические требования при эксплуатации тепловых сетей</div></div><div class="BY_DEFAULT"><div name="984028" id="984028"></div></div><div class="ACT_TEXT"><div name="984438" id="984438">1. Элементы (детали) трубопроводов должны быть заводского изготовления. Применять детали из труб с электросварным спиральным швом запрещается.</div></div><div class="ACT_TEXT"><div name="984439" id="984439">2. Все соединения элементов трубопроводов должны быть сварными. Применение фланцевых соединений допускается для присоединения трубопроводов к арматуре и деталям оборудования, имеющим фланцы. Допускается приварка фланцевой арматуры непосредственно к трубопроводам.</div></div><div class="ACT_TEXT"><div name="984440" id="984440">3. Для всех трубопроводов тепловых сетей, кроме тепловых пунктов и сетей горячего водоснабжения, для проектирования отопления запрещается применять арматуру:</div></div><div class="ACT_TEXT"><div name="984441" id="984441">из серого чугуна — в районах с расчетной температурой наружного воздуха ниже минус 10<sup>o</sup> С;</div></div><div class="ACT_TEXT"><div name="984442" id="984442">На спускных и дренажных устройствах применять арматуру из серого чугуна запрещается.</div></div><div class="ACT_TEXT"><div name="984443" id="984443">4. На водяных тепловых сетях диаметром 500 мм и более при условном давлении 1,6 МПа (16 кгс/см<sup>2</sup>) и более, диаметром 300 мм и более при условном давлении 2,5 МПа (25 кгс/см<sup>2</sup>) и более, на паровых сетях диаметром 200 мм и более при условном давлении 1,6 МПа (16 кгс/см<sup>2</sup>) и более у задвижек и затворов должны быть предусмотрены обводные трубопроводы (байпасы) с запорной арматурой.</div></div><div class="ACT_TEXT"><div name="984444" id="984444">5. Прокладки для фланцевых соединений должны изготовляться из паранита; для сальников должна применяться асбестовая прографиченная набивка или набивка из термостойкой резины.</div></div><div class="ACT_TEXT"><div name="984445" id="984445">Применение во фланцевых соединениях картонных и резиновых прокладок, а также применение хлопчатобумажных и пеньковых набивок запрещается.</div></div><div class="ACT_TEXT"><div name="984446" id="984446">6. Вентили и задвижки теплопроводов должны иметь:</div></div><div class="ACT_TEXT"><div name="984447" id="984447">а) надписи с наименованиями и номерами согласно оперативной схемы тепловых сетей и инструкции;</div></div><div class="ACT_TEXT"><div name="984448" id="984448">б) указатели направления движения теплоносителя и вращения маховика;</div></div><div class="ACT_TEXT"><div name="984449" id="984449">в) дистанционное механическое или электрическое управление в случае недоступности вентилей и задвижек для непосредственного обслуживания и когда непосредственное обслуживание затруднительно или связано с опасностью для персонала;</div></div><div class="ACT_TEXT"><div name="984450" id="984450">г) помимо ручного привода, задвижки диаметром 500 мм и более должны иметь механизированный привод (электрический или гидравлический).</div></div><div class="ACT_TEXT"><div name="984451" id="984451">Задвижки и затворы диаметром 500 мм и более должны иметь электропривод. При надземной прокладке тепловых сетей задвижки с электроприводами должны быть установлены в помещении или заключены в кожухи, защищающие арматуру и электропривод от атмосферных осадков и исключающие доступ к ним посторонних лиц.</div></div><div class="ACT_TEXT"><div name="984452" id="984452">7. Запорная арматура на тепловых сетях должна быть установлена:</div></div><div class="ACT_TEXT"><div name="984453" id="984453">на всех трубопроводах тепловых сетей от источника теплоты независимо от параметров теплоносителя и диаметров трубопроводов;</div></div><div class="ACT_TEXT"><div name="984454" id="984454">на трубопроводах водяных тепловых сетей диаметром 100 мм и более (секционирующие задвижки) на расстоянии не более 1000 м друг от друга;</div></div><div class="ACT_TEXT"><div name="984455" id="984455">в узлах ответвлений на трубопроводах диаметром 100 мм и более водяных и паровых тепловых сетей, а также к отдельным зданиям.</div></div><div class="ACT_TEXT"><div name="984514" id="984514">8. В нижних точках трубопроводов водяных тепловых сетей и конденсатопроводов, а также секционируемых участков должны быть смонтированы штуцера с запорной арматурой для спуска воды (спускные устройства).</div></div><div class="ACT_TEXT"><div name="984515" id="984515">9. Спуск воды из трубопроводов водяных тепловых сетей при подземной прокладке должен осуществляться в сбросные колодцы с отводом воды самотеком или в системы канализации передвижными насосами. Температура сбрасываемой из колодцев воды должна быть не выше 40<sup>o</sup> С. При отводе воды в бытовую канализацию на самотечном трубопроводе должен быть установлен гидрозатвор, а в случае возможности обратного тока воды — дополнительно отключающий (обратный) клапан.</div></div><div class="ACT_TEXT"><div name="984516" id="984516">10. Сбор конденсата от постоянных дренажей паропровода должен производиться в систему сбора конденсата. Допускается его отвод в напорный конденсатопровод, если давление в дренажном конденсатопроводе не менее чем 0,1 МПа (1 кгс/см<sup>2</sup>) выше, чем в напорном.</div></div><div class="ACT_TEXT"><div name="984517" id="984517">11. В высших точках трубопроводов тепловых сетей, в том числе на каждом секционном участке должны быть установлены штуцера с запорной арматурой для выпуска воздуха (воздушники).</div></div><div class="ACT_TEXT"><div name="984518" id="984518">12. В тепловых сетях должна быть обеспечена надежная компенсация тепловых удлинений трубопроводов.</div></div><div class="ACT_TEXT"><div name="984519" id="984519">13. На теплопроводах должны наноситься надписи следующего содержания на:</div></div><div class="ACT_TEXT"><div name="984520" id="984520">а) магистральных линиях — номер магистрали (римской цифрой) и стрелка, указывающая направление движения рабочей среды. В случае, если при нормальном режиме возможно движение ее в обе стороны, даются две стрелки, направленные в обе стороны;</div></div><div class="ACT_TEXT"><div name="984521" id="984521">б) ответственных ответвлениях вблизи магистралей номер магистрали (римской цифрой), буквенные обозначения агрегатов (установок), номера агрегатов (арабскими цифрами) и стрелки, указывающие направление движения рабочей среды;</div></div><div class="ACT_TEXT"><div name="984522" id="984522">в) ответвлениях от магистралей вблизи агрегатов, номер магистрали (римской цифрой) и стрелки, указывающие направление движения рабочей среды.</div></div><div class="ACT_TEXT"><div name="984523" id="984523">Буквенное обозначение агрегатов (установок)</div></div><div class="TABLE_STD" id="theDefCssID"><div name="984525" id="984525" class="tabBox"><table id="theTableID" style="PADDING-RIGHT: 0px; ; PADDING-LEFT: 0px; LEFT: 2px; PADDING-BOTTOM: 0px; WIDTH: 100%; BORDER-TOP-STYLE: none; PADDING-TOP: 0px; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TOP: 0px; BORDER-BOTTOM-STYLE: none" cellspacing="1" cols="5" border="1">
<colgroup>
<col />
<col />
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<td style="WIDTH: 187px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none"></td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="WIDTH: 186px; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td><font size="2">Насос‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">Н‎</font></td>
<td><font size="2">‎</font></td>
<td><font size="2">Турбонасос‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">ТН‎</font></td></tr>
<tr>
<td><font size="2">Турбина‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">Т‎</font></td>
<td><font size="2">‎</font></td>
<td><font size="2">Электронасос‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">ЭН‎</font></td></tr>
<tr>
<td><font size="2">Паровая машина‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">ПМ‎</font></td>
<td><font size="2">‎</font></td>
<td><font size="2">Деаэратор‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">Д‎</font></td></tr>
<tr>
<td><font size="2">Конденсатор‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">Кр‎</font></td>
<td><font size="2">‎</font></td>
<td><font size="2">Испаритель‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">И‎</font></td></tr>
<tr>
<td><font size="2">Отопление‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">От‎</font></td>
<td><font size="2">‎</font></td>
<td rowspan="3"><font size="2">‎‏Подогреватель регенеративной системы <br />‎</font></td>
<td style="TEXT-ALIGN: center" rowspan="3"><font size="2">‎‏<br />‎‏П<br />‎</font></td></tr>
<tr>
<td><font size="2">Вентиляция‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">Вт‎</font></td>
<td><font size="2">‎</font></td></tr>
<tr>
<td><font size="2">Технология‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">Тх‎</font></td>
<td><font size="2">‎</font></td></tr>
<tr>
<td><font size="2">Горячее водоснабжение‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">ГВС‎</font></td>
<td><font size="2">‎</font></td>
<td><font size="2">Прочие‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">Р‎</font></td></tr>
<tr>
<td><font size="2">Химводоочистка‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">ХВО‎</font></td>
<td><font size="2">‎</font></td>
<td><font size="2">‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">‎</font></td></tr>
<tr>
<td><font size="2">Бойлер‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">Б‎</font></td>
<td><font size="2">‎</font></td>
<td><font size="2">‎</font></td>
<td style="TEXT-ALIGN: center">‎</td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; BORDER-BOTTOM-STYLE: none">‎</td></tr></tbody></table></div></div><div class="ACT_TEXT"><div name="984526" id="984526">14. Размеры букв и цифр устанавливаются в зависимости от наружного диаметра трубопровода (изоляции): от 150 до 300 мм, высота букв должна быть 100 мм; свыше 300 мм — 150 мм, если при этом соблюдается условие видимости надписи при слабом освещении на расстоянии 5 м, в противном случае высота букв увеличивается.</div></div><div class="ACT_TEXT"><div name="984527" id="984527">15. На трубопроводах с наружным диаметром изоляции менее 150 мм надписи наносятся на специальных табличках, прикрепляемых с помощью хомутов на трубопроводах (над или под ними) в вертикальной плоскости. Примерные размеры табличек для нанесения надписей и обозначений приводятся ниже.</div></div><div class="TABLE_STD" id="theDefCssID"><div name="984528" id="984528" class="tabBox"><table id="theTableID" style="PADDING-RIGHT: 0px; ; PADDING-LEFT: 0px; LEFT: 2px; PADDING-BOTTOM: 0px; WIDTH: 100%; BORDER-TOP-STYLE: none; PADDING-TOP: 0px; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TOP: 0px; BORDER-BOTTOM-STYLE: none" cellspacing="1" cols="3" border="1">
<colgroup>
<col />
<col />
<col /></colgroup>
<tbody>
<tr>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center" rowspan="2">
<p align="center"><strong><font size="2">‎‏Высота букв надписи, мм<br />‎</font></strong></p></td>
<td style="TEXT-ALIGN: center" colspan="2">
<p align="center"><strong><font size="2">Размеры таблички, мм‎‎</font></strong></p></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><strong><font size="2">высота‎</font></strong></td>
<td style="TEXT-ALIGN: center"><strong><font size="2">длина‎</font></strong></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">100‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">200‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">От 350 до 400‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">150‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">250‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">От 400 до 700‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">225‎</font></td>
<td style="TEXT-ALIGN: center"><font size="2">350‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">От 700 до 800‎</font></td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td></tr></tbody></table></div></div><div class="ACT_TEXT"><div name="984529" id="984529">16. Помимо окраски поверхности изоляции трубопровода, на нем должны быть нанесены цветные кольца. Цвет окраски колец дан в <a href="/acts/973665#984009">приложении № 4</a> к настоящим Правилам.</div></div><div class="ACT_TEXT"><div name="984530" id="984530">Расстояние между кольцами в зависимости от местных условий должно быть от 1 до 5 м. Для удобства ориентировки кольца обязательно должны наноситься перед входом и после выхода из стены, а также по обе стороны задвижек и вентилей. Трубопроводы в непроходных каналах и при бесканальной прокладке окрашиваются только в пределах камер.</div></div><div class="ACT_TEXT"><div name="984531" id="984531">Размеры колец приведены ниже.</div></div><div class="TABLE_STD" id="theDefCssID"><div name="984532" id="984532" class="tabBox"><table id="theTableID" style="PADDING-RIGHT: 0px; ; PADDING-LEFT: 0px; LEFT: 2px; PADDING-BOTTOM: 0px; WIDTH: 100%; PADDING-TOP: 0px; TOP: 0px" cellspacing="1" cols="2" border="1">
<colgroup>
<col />
<col /></colgroup>
<tbody>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Наружный диаметр трубопровода или изоляции, мм‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Ширина цветного кольца, мм‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">До 150‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">50‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">От 150 до 300‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">70‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Более 300‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">100‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center">‎</td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td></tr>
<tr>
<td style="TEXT-ALIGN: center">‎</td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center">‎</td></tr></tbody></table></div></div><div class="ACT_TEXT"><div name="984533" id="984533">17. При покрытии поверхности изоляции трубопровода металлической обшивкой (листами алюминия, оцинкованного железа и другими коррозионностойкими металлами) окраска обшивки по всей длине может не производиться. В этом случае в зависимости от транспортируемой среды должны наноситься условные обозначения и кольца в соответствии с требованиями <a href="/acts/973665#984519">п. 13 </a>настоящего приложения на прямых участках трубопроводов не реже чем через каждые 50 м, перед входом в стену, после выхода из нее, у измерительных приборов, задвижек, вентилей и другой арматуры.</div></div><div class="ACT_TEXT"><div name="984534" id="984534">18. Горизонтальные участки теплопроводов должны быть уложены с уклоном не менее 0,002 и иметь в нижних точках дренажи с вентилями.</div></div><div class="ACT_TEXT"><div name="984535" id="984535">19. В тепловых сетях должна быть обеспечена надежная компенсация температурных удлинений теплопроводов с разделением компенсируемых участков неподвижными опорами. Сальниковые компенсаторы должны иметь реперы, обозначающие предельные положения стакана компенсатора в холодном и горячем состоянии.</div></div><div class="ACT_TEXT"><div name="984766" id="984766">20. На паропроводах диаметром более 150 мм и температурой пара 300<sup>o</sup> С и выше должны быть установлены индикаторы для контроля за расширением паропровода и наблюдения за правильностью работы опор.</div></div><div class="ACT_TEXT"><div name="984769" id="984769">21. Для контроля параметров теплоносителя тепловая сеть должна быть оборудована штуцерами для манометров и гильзами для термометров на подающих и обратных трубопроводах основных магистралей водяной сети, во всех точках изменения диаметров, а также в крупных узловых точках с диаметром ответвления более 150 мм.</div></div><div class="ACT_TEXT"><div name="984770" id="984770">Для контроля за параметрами теплоносителя тепловая сеть должна быть оборудована отборными устройствами для измерения:</div></div><div class="ACT_TEXT"><div name="984771" id="984771">температуры в подающих и обратных трубопроводах перед секционирующими задвижками и в обратном трубопроводе ответвлений диаметром 300 мм и более перед задвижкой по ходу воды;</div></div><div class="ACT_TEXT"><div name="984772" id="984772">давления воды в подающих и обратных трубопроводах до и после секционирующих задвижек и регулирующих устройств, в прямом и обратном трубопроводах ответвлений перед задвижкой;</div></div><div class="ACT_TEXT"><div name="984773" id="984773">давления пара в трубопроводах ответвлений перед задвижкой.</div></div><div class="ACT_TEXT"><div name="984774" id="984774">22. В камерах тепловых сетей должны быть установлены местные показывающие контрольно-измерительные приборы для измерения температуры и давления в трубопроводах.</div></div><div class="ACT_TEXT"><div name="984776" id="984776">23. Трубопроводы с температурой теплоносителя выше 45<sup>o</sup> С, расположенные в помещениях или вне помещений, а также их фланцевые соединения и арматура должны иметь тепловую изоляцию. Тепловую изоляцию должны иметь также трубопроводы, расположенные вне помещений, с температурой теплоносителя выше 60<sup>o</sup> С.</div></div><div class="ACT_TEXT"><div name="984777" id="984777">Конструкция тепловой изоляции фланцевых соединений и арматуры должна быть съемной.</div></div><div class="ACT_TEXT"><div name="984778" id="984778">Теплоиспользующие открытые установки и подводящие к ним теплопроводы должны иметь поверх изоляции защитные дюралюминиевые кожухи или другие заменяющие их полиамидные покрытия с достаточной механической прочностью и надежным долговечным их креплением.</div></div><div class="ACT_TEXT"><div name="984779" id="984779">Запрещается применение изоляционных материалов огнеопасных, подверженных гниению, содержащих сернистые соединения или способных выделять кислоты и крепкие щелочи.</div></div><div class="ACT_TEXT"><div name="984780" id="984780">Для предохранения от коррозии металлических конструкций тепловых сетей (балок, перекрытий, мертвых опор, эстакад, мачт и других элементов) в доступных местах должна производиться их окраска.</div></div><div class="ACT_TEXT"><div name="984781" id="984781">Периодичность окраски устанавливается в зависимости от местных условий.</div></div><div class="ACT_TEXT"><div name="984784" id="984784">Допускается при технико-экономическом обосновании предусматривать прокладку без тепловой изоляции:</div></div><div class="ACT_TEXT"><div name="984785" id="984785">обратных трубопроводов тепловых сетей в цехах предприятий, тепловой поток которых используется для отопления;</div></div><div class="ACT_TEXT"><div name="984786" id="984786">конденсатных сетей при их совместной прокладке с паровыми сетями в непроходных каналах.</div></div><div class="ACT_TEXT"><div name="984787" id="984787">Тепловая изоляция фланцевых соединений, арматуры, участков трубопроводов, подвергающихся периодическому контролю, а также сальниковых, линзовых и сильфонных компенсаторов должна быть съемной.</div></div><div class="ACT_TEXT"><div name="984789" id="984789">Тепловые сети, проложенные вне помещений, независимо от вида прокладки, должны иметь защиту от воздействия влаги.</div></div><div class="ACT_TEXT"><div name="984791" id="984791">24. Наружная поверхность трубопроводов и металлических конструкций тепловых сетей (балки, опоры, мачты, эстакады и др.) должна быть защищена стойкими антикоррозийными покрытиями.</div></div><div class="ACT_TEXT"><div name="984792" id="984792">Ввод в эксплуатацию тепловых сетей после окончания строительства или капитального ремонта без наружного антикоррозийного покрытия труб и металлических конструкций запрещается.</div></div><div class="ACT_TEXT"><div name="984793" id="984793">25. При подземной прокладке (в непроходных каналах и бесканальной) трубопроводы тепловых сетей должны быть защищены от наружной коррозии, вызываемой взаимодействием металла трубопроводов с увлажненной изоляцией или высокой коррозийной активностью грунтов, а также блуждающими токами. Защиту необходимо предусматривать в соответствии с действующими КМК, ШНК.</div></div><div class="ACT_TEXT"><div name="984794" id="984794">26. На мачтах и участках эстакад, а также под кронштейнами, где установлены на высоте свыше 2,5 м элементы оборудования, требующие обслуживания или периодического осмотра, должны быть сооружены площадки с перилами и постоянными лестницами.</div></div><div class="ACT_TEXT"><div name="984795" id="984795">27. Элементы оборудования, арматура и приборы теплового контроля, дистанционного управления подземных теплопроводов, подвергающихся периодическому осмотру и обслуживанию, должны размещаться в специальных камерах или подвалах, доступных для обслуживающего персонала.</div></div><div class="ACT_TEXT"><div name="984797" id="984797">28. В камерах обслуживания подземных прокладок должно быть не менее двух люков с лестницами или скобами. В камерах с внутренней площадью до 2,5 м<sup>2</sup> допускается устройство одного люка.</div></div><div class="ACT_TEXT"><div name="984799" id="984799">Вдоль трассы проходных и полупроходных каналов такие люки должны быть устроены не реже чем через каждые 300 м. Люки камер должны иметь надежные запоры и не пропускать поверхностные воды.</div></div><div class="ACT_TEXT"><div name="984800" id="984800">Аварийные люки должны легко открываться изнутри. Конструкция запоров люков проходных и полупроходных каналов (туннелей) должна обеспечивать легкое открывание люков изнутри канала (туннеля).</div></div><div class="ACT_TEXT"><div name="984804" id="984804">29. Проходные каналы, а также крупные узловые камеры, в которых установлено электрооборудование, должны иметь постоянное искусственное освещение, оборудованное согласно Правилам устройства электроустановок для помещений особо сырых и с повышенной температурой воздуха.</div></div><div class="ACT_TEXT"><div name="984807" id="984807">В случаях возможности проникновения в эти помещения взрывоопасных газов для освещения должна применяться взрывобезопасная арматура.</div></div><div class="ACT_TEXT"><div name="984809" id="984809">Места установки электрооборудования (насосные, тепловые пункты, туннели, камеры), а также места установки арматуры с электроприводом, регуляторов и контрольно-измерительных приборов должны иметь электрическое освещение, соответствующее Правилам устройства электроустановок.</div></div><div class="ACT_TEXT"><div name="984811" id="984811">30. Диаметр спускных и воздушных штуцеров должен определяться из условия опорожнения трубопровода Ж до 300 мм не более двух часов, Ж 500 мм не более четырех часов.</div></div><div class="ACT_TEXT"><div name="984813" id="984813">На транзитных магистралях расстояние между секционирующими задвижками могут быть увеличены при условии обеспечения спуска воды из трубопроводов участка в вышеуказанный срок.</div></div><div class="ACT_TEXT"><div name="985105" id="985105">31. Во всех нижних точках трассы паропроводов и перед вертикальными участками должны предусматриваться дренажные устройства для продувки.</div></div><div class="ACT_TEXT"><div name="985106" id="985106">При попутном уклоне паропроводов спусковые дренажные устройства должны быть установлены через каждые 400—500 м, при встречном уклоне — через каждые 200—300 м.</div></div><div class="ACT_TEXT"><div name="985107" id="985107">Для паровых сетей, транспортирующих насыщенный пар, спусковые дренажи должны быть установлены: на прямых участках при попутном уклоне — через каждые 250—300 м, при встречном уклоне — через каждые 200 м.</div></div><div class="ACT_TEXT"><div name="985108" id="985108">32. Во всех нижних точках участков паропровода, в которых в процессе эксплуатации состояние пара приближается к насыщенному, должны быть установлены автоматические конденсатоотводчики.</div></div><div class="ACT_TEXT"><div name="985109" id="985109">33. Для дренажа каналов и туннелей дно канала вдоль трассы теплопровода должно иметь уклон не менее 0,003. В низких точках трассы должно быть предусмотрено устройство для отвода воды. При отсутствии возможности самотечного стока воды должна быть обеспечена периодическая откачка воды. Подъем уровня воды в каналах до низа изоляции теплопроводов не допускается.</div></div><div class="ACT_TEXT"><div name="985110" id="985110">34. Соединения теплопроводов с канализацией должны выполняться с разрывом (через раковину, воронку или гидрозатвор).</div></div><div class="ACT_TEXT"><div name="985111" id="985111">Все подключения водопровода к теплопроводам должны выполняться на сгонах, которые в условиях нормальной эксплуатации должны быть разъединены.</div></div><div class="ACT_TEXT"><div name="985112" id="985112">35. Допускается совмещение прокладки тепловых сетей с другими трубопроводами в общем канале, за исключением трубопроводов с легковоспламеняющимися, химически едкими и ядовитыми веществами, прокладка которых в общем канале с тепловыми сетями категорически запрещается.</div></div><div class="ACT_TEXT"><div name="985113" id="985113">36. В местах прокладки теплопроводов возведение строений, складирование, посадка деревьев и многолетних кустарников на расстоянии менее 2 м от проекции на поверхность земли края строительной конструкции тепловой сети или бесканального трубопровода запрещается.</div></div><div class="ACT_TEXT"><div name="985114" id="985114">37. При воздушной прокладке теплопроводов через улицы и проезды высота расположения трубопроводов от уровня земли до наружной поверхности изоляции должна быть не менее 4,5 м, кроме случаев прокладки через железнодорожное полотно, когда расстояние от головки рельса до наружной поверхности изоляции должно быть не менее 6,4 м, а для электрифицированных дорог — не менее 7,0 м.</div></div><div class="ACT_TEXT"><div name="985115" id="985115">38. В тех случаях, когда расстояние от нижней точки изоляции теплопроводов до уровня земли меньше 2 м, места прохода должны быть снабжены специальными переходными устройствами.</div></div><div class="ACT_TEXT"><div name="985116" id="985116">39. Все тепловые сети перед вводом их в постоянную эксплуатацию должны подвергаться следующим видам испытаний:</div></div><div class="ACT_TEXT"><div name="985117" id="985117">а) на плотность (опрессовке) для проверки механической прочности трубопроводов и арматуры;</div></div><div class="ACT_TEXT"><div name="985118" id="985118">б) на расчетную температуру теплоносителя для проверки прочности и компенсирующей способности сети в условиях температурных деформаций при подъеме температуры теплоносителя до расчетного значения;</div></div><div class="ACT_TEXT"><div name="985119" id="985119">в) гидравлическим для определения гидравлических характеристик трубопроводов;</div></div><div class="ACT_TEXT"><div name="985122" id="985122">г) тепловым для определения фактических тепловых потерь сети. </div></div><div class="ACT_TEXT"><div name="985123" id="985123">На основе данных испытаний при сдаче тепловой сети в эксплуатацию устанавливается норма тепловых потерь, которая утверждается руководителем (или главным инженером) предприятия. Контрольные измерения тепловых потерь и гидравлических характеристик трубопроводов производятся один раз в 5 лет.</div></div><div class="ACT_TEXT"><div name="985124" id="985124">40. Трубопроводы тепловых сетей до пуска их в эксплуатацию после монтажа или капитального ремонта должны подвергаться очистке:</div></div><div class="ACT_TEXT"><div name="985125" id="985125">а) паропроводы — продувке со сбросом пара в атмосферу;</div></div><div class="ACT_TEXT"><div name="985126" id="985126">б) водяные сети в закрытых системах теплоснабжения и конденсатопроводы — гидропневматической промывке;</div></div><div class="ACT_TEXT"><div name="985127" id="985127">в) водяные сети в открытых системах теплоснабжения — гидропневматической промывке и дезинфекции с последующей повторной промывкой питьевой водой.</div></div><div class="ACT_TEXT"><div name="985128" id="985128">Повторная промывка после дезинфекции должна производиться до достижения показателей качества сбрасываемой воды, соответствующих санитарным нормам на питьевую воду.</div></div><div class="ACT_TEXT"><div name="985130" id="985130">41. Гидравлическая опрессовка осуществляется пробным давлением 1,25 рабочего, но не менее чем рабочее давление плюс 3 105 Па (3 кгс/см<sup>2</sup>). Трубопроводы выдерживаются под пробным давлением не менее 5 мин., после чего давление снижается до рабочего. При рабочем давлении проводится тщательный осмотр трубопроводов по всей их длине. Результаты опрессовки считаются удовлетворительными, если во время ее проведения не произошло падения давления и не обнаружены признаки разрыва, течи или запотевания в корпусах и сальниках арматуры, во фланцевых соединениях и т. п.</div></div><div class="ACT_TEXT"><div name="985132" id="985132">42. Гидравлическую опрессовку арматуры следует производить до ее установки на трубопроводы для испытания на прочность и плотность металла и на герметичность подвижных и неподвижных разъемных соединений (сальникового устройства, запорных органов и др.). При гидравлической опрессовке арматуры пробное давление должно соответствовать государственному стандарту «Арматура и детали трубопроводов. Давления условные, пробные и рабочие. Ряды».</div></div><div class="ACT_TEXT"><div name="985133" id="985133">43. Пуск тепловых сетей после монтажа, ремонта или временной остановки производится по заранее составленной программе, согласованной с теплоснабжающей организацией.</div></div><div class="ACT_TEXT"><div name="985134" id="985134">44. Пуск паровых сетей должен состоять из следующих операций:</div></div><div class="ACT_TEXT"><div name="985135" id="985135">а) прогрева и продувки паропроводов;</div></div><div class="ACT_TEXT"><div name="985136" id="985136">б) заполнения и промывки конденсатопроводов;</div></div><div class="ACT_TEXT"><div name="985138" id="985138">в) подключения потребителей и пусковая регулировка сети. Перед началом прогрева все задвижки на ответвлении от прогреваемого участка должны быть плотно закрыты.</div></div><div class="ACT_TEXT"><div name="985139" id="985139">Вначале должна быть прогрета основная магистраль, а затем поочередно ее ответвления. Для паропроводов небольшой протяженности (не свыше 200 м) прогрев основного паропровода и ответвлений от него может производиться одновременно.</div></div><div class="ACT_TEXT"><div name="985140" id="985140">45. Пуск водяных сетей заключается в проведении следующих основных операций:</div></div><div class="ACT_TEXT"><div name="985141" id="985141">а) заполнение сети водой;</div></div><div class="ACT_TEXT"><div name="985142" id="985142">б) промывка сети;</div></div><div class="ACT_TEXT"><div name="985143" id="985143">в) установление циркуляции;</div></div><div class="ACT_TEXT"><div name="985144" id="985144">г) проверка плотности сети;</div></div><div class="ACT_TEXT"><div name="985146" id="985146">д) включение потребителей и пусковая регулировка сети.</div></div><div class="ACT_TEXT"><div name="985147" id="985147">При пуске водяной сети после монтажа промывка ее производится через временные грязевики, устанавливаемые в концах подающего и обратного теплопроводов (по ходу воды). Грязевики удаляются через год после второй промывки.</div></div><div class="ACT_TEXT"><div name="985148" id="985148">Трубопроводы тепловых сетей должны заполняться водой температурой не выше 70<sup>o</sup> С при отключенных системах теплопотребления.</div></div><div class="ACT_TEXT"><div name="985149" id="985149">46. В период пуска необходимо вести наблюдение за наполнением и прогревом трубопроводов, состоянием запорной арматуры, сальниковых компенсаторов, дренажных устройств.</div></div><div class="ACT_TEXT"><div name="985150" id="985150">Последовательность и скорость проведения пусковых операций должны быть такими, чтобы исключить возможность значительных тепловых деформаций трубопроводов. В случае повреждения пусковых трубопроводов или связанного с ними оборудования должны быть приняты меры к ликвидации этих повреждений.</div></div><div class="ACT_TEXT"><div name="985152" id="985152">47. Регулирование расхода теплоносителя запорной арматурой не допускается.</div></div><div class="ACT_TEXT"><div name="985153" id="985153">48. Ежегодно после окончания отопительного сезона должна производиться гидравлическая опрессовка тепловых сетей и вводов для выявления дефектов, подлежащих устранению при капитальном ремонте.</div></div><div class="ACT_TEXT"><div name="985154" id="985154">После ремонта тепловые сети вновь подвергаются гидравлической опрессовке.</div></div><div class="ACT_TEXT"><div name="985155" id="985155">При воздушной прокладке тепловых сетей по согласованию с инспекцией «Узгосэнергонадзор» допускается гидравлическое испытание производить по мере необходимости (ремонт, связанный со сваркой; при пуске трубопроводов после нахождения их в состояниях консервации свыше 2-х лет), но не реже одного раза в пять лет.</div></div><div class="ACT_TEXT"><div name="985156" id="985156">49. На предприятиях, эксплуатирующих тепловые сети, должны проводиться их испытания на расчетную температуру теплоносителя, на определение тепловых и гидравлических потерь и на наличие потенциала блуждающих токов.</div></div><div class="ACT_TEXT"><div name="985157" id="985157">Необходимость и периодичность указанных видов испытаний определяет руководитель (или главный инженер) предприятия.</div></div><div class="ACT_TEXT"><div name="985158" id="985158">Испытания на наличие потенциала блуждающих токов должны проводиться с периодичностью, установленной Инструкцией по защите тепловых сетей от электрохимической коррозии.</div></div><div class="ACT_TEXT"><div name="985159" id="985159">В отдельных случаях могут проводиться контрольные вскрытия (шурфовки) тепловых сетей, необходимость выполнения которых определяет ответственный за техническое состояние тепловых сетей предприятия.</div></div><div class="ACT_TEXT"><div name="985160" id="985160">Все испытания тепловых сетей должны выполняться раздельно и в соответствии с отраслевыми документами: «Методические указания по испытаниям водяных тепловых сетей на расчетную температуру теплоносителя»; «Методические указания по испытанию водяных тепловых сетей на гидравлические потери»; «Методические указания по определению тепловых потерь в водяных и паровых тепловых сетях».</div></div><div class="ACT_TEXT"><div name="985161" id="985161">50. Для надзора за состоянием подземных теплопроводов в местах наиболее опасных в отношении наружной коррозии и увлажнения теплоизоляции не реже 1 раза в 2 года должна производиться шурфовка тепловой сети (вскрытие грунта), строительной конструкции и тепловой изоляции из расчета не менее одного шурфа на 2 километра трассы и не менее одного шурфа в три года при меньшей протяженности трассы. Все работы по проведению шурфовки ведутся с третьего года эксплуатации тепловых сетей.</div></div><div class="ACT_TEXT"><div name="985162" id="985162">На каждое вскрытие должен быть составлен акт, в котором отмечается состояние грунта, строительных конструкций, изоляции труб и метод восстановления конструкций.</div></div><div class="ACT_TEXT"><div name="985163" id="985163">51. В процессе текущей эксплуатации тепловых сетей необходимо: </div></div><div class="ACT_TEXT"><div name="985164" id="985164">а) поддерживать в исправном состоянии все оборудование, строительные и другие конструкции тепловых сетей, проводя своевременно их осмотр и ремонт; </div></div><div class="ACT_TEXT"><div name="985165" id="985165">б) наблюдать за работой компенсаторов, опор, арматуры, дренажей, контрольно-измерительных приборов и других элементов оборудования, своевременно устраняя выявленные дефекты и неплотности;</div></div><div class="ACT_TEXT"><div name="985166" id="985166">в) не допускать сверхнормативных потерь тепловой энергии и теплоносителя путем отключения неработающих участков сети, удаления скапливающейся в каналах и камерах воды, предотвращения попадания туда грунтовых и верховых вод, выявлять и восстанавливать разрушенную изоляцию;</div></div><div class="ACT_TEXT"><div name="985167" id="985167">г) своевременно удалять воздух из теплопроводов через воздушники, не допускать присоса воздуха в тепловые сети, поддерживая постоянно необходимое избыточное давление во всех точках сети и системах теплопотребления;</div></div><div class="ACT_TEXT"><div name="985168" id="985168">д) поддерживать чистоту в камерах и проходных каналах, не допускать пребывания в них посторонних лиц; </div></div><div class="ACT_TEXT"><div name="985169" id="985169">е) принимать меры к предупреждению, локализации и ликвидации дефектов и отказов в работе тепловой сети.</div></div><div class="ACT_TEXT"><div name="985170" id="985170">52. За внутренней коррозией водяных тепловых сетей и конденсатопроводов должен вестись систематический контроль путем анализов сетевой воды и конденсата, а также установка индикаторов коррозии в наиболее характерных точках.</div></div><div class="ACT_TEXT"><div name="985171" id="985171">Подпитка тепловой сети должна производиться умягченной деаэрированной водой.</div></div><div class="ACT_TEXT"><div name="985172" id="985172">Избыточное давление в сети во всех присоединенных системах в любой точке должно быть не ниже 0,05 МПа (0,5 кгс/см<sup>2</sup>) как при циркуляции теплоносителя, так и в случае временного ее прекращения. Неработающая тепловая сеть должна заполняться только деаэрированной водой и находиться под избыточным давлением. </div></div><div class="ACT_TEXT"><div name="985173" id="985173">53. Для контроля за внешней коррозией трубопроводов от блуждающих токов тепловая сеть не реже 1 раза в 3 года должна быть проверена электроразведкой; при обнаружении электрокоррозии должны быть приняты меры по защите от блуждающих токов. Контрольная проверка участков, на которых обнаружена коррозия, должна производиться не реже 1 раза в год.</div></div><div class="ACT_TEXT"><div name="985174" id="985174">54. Для контроля гидравлического и температурного режимов тепловых сетей и теплоиспользующих установок необходимо при плановых обходах проверять давление и температуру в узловых точках сети по манометрам и термометрам.</div></div><div class="ACT_TEXT"><div name="985175" id="985175">55. Среднегодовая утечка теплоносителя в тепловых сетях не должна превышать 0,25% от объема воды в работающей сети и присоединенных к ней местных систем.</div></div><div class="ACT_TEXT"><div name="985176" id="985176">В пределах этой нормы для каждой тепловой сети сезонная норма утечки теплоносителя устанавливается теплоснабжающей организацией.</div></div><div class="ACT_TEXT"><div name="985177" id="985177">При утечке теплоносителя, превышающей установленные нормы, должны быть приняты меры к обнаружению места утечек и их устранению. Повышенная утечка воды определяется по увеличению расхода подпитки на источнике теплоты и (или) увеличению разности расходов в подающем и обратном трубопроводах при установившемся тепловом режиме системы.</div></div><div class="ACT_TEXT"><div name="985178" id="985178">56. При обходе трубопроводов необходимо проверять состояние дренажных и воздушных кранов и вентилей, устраняя их неплотности и загрязнение, а также периодически освобождая трубопроводы от скапливающегося воздуха эксплуатация трубопроводов при неработающем дренаже запрещается.</div></div><div class="ACT_TEXT"><div name="985179" id="985179">57. В процессе эксплуатации тепловых сетей следует периодически проверять правильность показаний установленных расходомеров, манометров, термометров и других контрольно-измерительных приборов по эталонным контрольным приборам. Неисправные контрольно-измерительные приборы должны быть заменены.</div></div><div class="ACT_TEXT"><div name="985180" id="985180">58. Ежегодно перед началом отопительного сезона все насосные станции необходимо подвергать комплексному опробованию для определения качества ремонта, правильности работы и взаимодействия всего тепломеханического и электротехнического оборудования, средств контроля, автоматики, телемеханики, защиты оборудования системы теплоснабжения и определения степени готовности насосных станций к отопительному сезону.</div></div><div class="ACT_TEXT"><div name="985181" id="985181">59. Текущий осмотр оборудования автоматизированных насосных станций следует проводить ежесменно, проверяя нагрузку электрооборудования, температуру подшипников, наличие смазки, состояние сальников, действие системы охлаждения, наличие диаграммных лент в регистрирующих приборах.</div></div><div class="ACT_TEXT"><div name="985182" id="985182">60. На неавтоматизированных насосных станциях должно быть организовано ежесменное обслуживание оборудования.</div></div><div class="ACT_TEXT"><div name="985183" id="985183">61. Перед запуском насосов, а при их работе 1 раз в сутки необходимо проверять состояние насосного и связанного с ним оборудования. В дренажных насосных станциях не реже 2 раз в неделю следует контролировать воздействие регулятора уровня на устройство автоматического включения насосов.</div></div><div class="ACT_TEXT"><div name="985184" id="985184">62. При эксплуатации автоматических регуляторов должны проводиться периодические осмотры их состояния, проверка работы, очистка и смазка движущихся частей, корректировка и настройка регулирующих органов на поддержание заданных параметров. Устройства автоматизации и технологической защиты тепловых сетей могут быть выведены из работы только по распоряжению главного энергетика, кроме случаев отключения отдельных защит при пуске оборудования, предусмотренных местной инструкцией.</div></div><div class="ACT_TEXT"><div name="985185" id="985185">63. Для подпитки тепловых сетей и систем на тепловых пунктах устанавливаются подпиточные устройства (насосы, баки). Производительность подпиточных устройств и водоподготовки в закрытой системе теплоснабжения должна компенсировать утечку воды в размере 0,5% объема тепловой сети и систем. При непосредственном водоразборе на горячее водоснабжение производительность подпиточных устройств и водоподготовки должна обеспечивать дополнительную подачу воды по среднечасовому расходу — при наличии баков-аккумуляторов и по максимальному расходу — при их отсутствии.</div></div><div class="ACT_TEXT"><div name="985187" id="985187">64. Капитальный и текущий ремонты тепловых сетей должны производиться по планам, составляемым на основании выявленных дефектов во время эксплуатации, опрессовки и испытаний тепловых сетей.</div></div><div class="ACT_TEXT"><div name="985188" id="985188">65. В тепловых сетях, имеющих в течение года сезонный перерыв в работе, капитальный ремонт производится 1 раз в год. Допускается удлинение периода работы тепловых сетей между капитальными ремонтами до 2 лет.</div></div><div class="ACT_TEXT"><div name="985189" id="985189">66. В тепловых сетях, работающих в течение года без перерыва, ремонт производится 1 раз в 2-3 года одновременно с ремонтом теплофикационного оборудования.</div></div><div class="ACT_TEXT"><div name="985190" id="985190">Текущий ремонт тепловых сетей должен производиться не реже 1 раза в год.</div></div><div class="ACT_TEXT"><div name="985191" id="985191">67. Одновременно с ремонтом магистральных теплопроводов должен производиться также ремонт всех ответвлений от него, тепловых вводов, узлов управления, местных систем и КИПа. </div></div><div class="ACT_TEXT"><div name="985192" id="985192">68. По окончании ремонта тепловые сети должны быть промыты до полного осветления воды и испытаны пробным давлением 1,25 рабочего, но не менее чем рабочее давление плюс 0,3 МПа (3 кгс/см<sup>2</sup>). Трубопроводы выдерживаются под пробным давлением не менее 5 мин., после чего давление снижается до рабочего.</div></div><div class="ACT_TEXT"><div name="985193" id="985193">За рабочее давление принимается:</div></div><div class="ACT_TEXT"><div name="985194" id="985194">а) для магистральных теплопроводов и ответвлений до теплового пункта — давление на коллекторе ТЭЦ или котельной (в соответствии с проектом);</div></div><div class="ACT_TEXT"><div name="985195" id="985195">б) для внутренних теплопроводов — давление на подающем трубопроводе (коллекторе) теплового пункта (в соответствии с проектом). Приемка тепловых сетей из ремонта производится в соответствии с <a href="/acts/973665#983147">п. 97 </a>настоящих Правил.</div></div><div class="ACT_TEXT"><div name="985196" id="985196">69. При отсутствии необходимости включения сети после ремонта в эксплуатацию для сезонной консервации теплопроводы должны быть заполнены умягченной деаэрированной водой или конденсатом.</div></div><div class="BY_DEFAULT"><div name="985197" id="985197"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985198" id="985198">ПРИЛОЖЕНИЕ № 6 <br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985199" id="985199">Технические требования при эксплуатации тепловых пунктов </div></div><div class="BY_DEFAULT"><div name="985200" id="985200"></div></div><div class="ACT_TEXT"><div name="985201" id="985201">1. В тепловом пункте необходимо следует размещать оборудование, арматуру, приборы контроля, управления и автоматизации, посредством которых осуществляются:</div></div><div class="ACT_TEXT"><div name="985202" id="985202">преобразование вида теплоносителя или изменение его параметров;</div></div><div class="ACT_TEXT"><div name="985203" id="985203">контроль параметров теплоносителя;</div></div><div class="ACT_TEXT"><div name="985204" id="985204">учет тепловой энергии, расходов теплоносителя и конденсата;</div></div><div class="ACT_TEXT"><div name="985205" id="985205">регулирование расхода теплоносителя и распределение его по системам теплопотребления;</div></div><div class="ACT_TEXT"><div name="985206" id="985206">защита местных систем от аварийного повышения параметров теплоносителя; заполнение и подпитка систем теплопотребления;</div></div><div class="ACT_TEXT"><div name="985207" id="985207">сбор, охлаждение, возврат конденсата и контроль его качества;</div></div><div class="ACT_TEXT"><div name="985208" id="985208">аккумулирование тепловой энергии;</div></div><div class="ACT_TEXT"><div name="985210" id="985210">водоподготовка для систем горячего водоснабжения;</div></div><div class="ACT_TEXT"><div name="985211" id="985211">Вводимые в эксплуатацию все тепловые пункты (ТП, ИТП, ЦТП, паровой системы теплопотребления) должны оснащаться современными автоматизированными приборами учета тепловой энергии.</div></div><div class="ACT_TEXT"><div name="985213" id="985213">2. Для предприятий с числом отапливаемых зданий более одного обязательно устройство ЦТП. На предприятиях, имеющих собственные источники теплоты, ЦТП может быть оборудован на источнике теплоты.</div></div><div class="ACT_TEXT"><div name="985214" id="985214">Для каждого здания обязательно устройство ИТП, в котором должно быть смонтировано оборудование, необходимое для его присоединения к тепловой сети, а также оборудование, отсутствующее (не установленное) в ЦТП.</div></div><div class="ACT_TEXT"><div name="985215" id="985215">3. Схемы подсоединения потребителей тепловой энергии к водяным тепловым сетям в тепловых пунктах должны обеспечивать минимальный удельный расход сетевой воды и экономию тепловой энергии.</div></div><div class="ACT_TEXT"><div name="985216" id="985216">4. Тепловой пункт должен быть оборудован:</div></div><div class="ACT_TEXT"><div name="985217" id="985217">а) запорной арматурой на подающих и обратных трубопроводах сетевой воды, а также на трубопроводах пара и конденсата;</div></div><div class="ACT_TEXT"><div name="985218" id="985218">б) устройствами для выпуска воздуха в верхних точках и дренирования в нижних точках;</div></div><div class="ACT_TEXT"><div name="985219" id="985219">в) самопишущими приборами для измерения давления, температуры и расхода горячей воды в подающем и обратном трубопроводах тепловой сети, также в паропроводах и магистральном конденсатопроводе;</div></div><div class="ACT_TEXT"><div name="985220" id="985220">г) водомером на обводе основной задвижки обратного или прямого теплопровода для контроля плотности водяной сети;</div></div><div class="ACT_TEXT"><div name="985221" id="985221">д) показывающими приборами для измерения давления: </div></div><div class="ACT_TEXT"><div name="985223" id="985223">на подающем и обратном трубопроводах до входных задвижек, на каждом подающем трубопроводе после задвижек на распределительном коллекторе;</div></div><div class="ACT_TEXT"><div name="985224" id="985224">на всасывающем и нагнетательном патрубках каждого насоса;</div></div><div class="ACT_TEXT"><div name="985225" id="985225">е) показывающими термометрами: на всех обратных трубопроводах сетевой воды, перед сборным обратным коллектором, на общем подающем и обратном теплопроводах, конденсатопроводах.</div></div><div class="ACT_TEXT"><div name="985226" id="985226">Требования к оборудованию тепловых пунктов местных систем даны в <a href="/acts/973665#983733">§ 12 </a>главы III настоящих Правил.</div></div><div class="ACT_TEXT"><div name="985227" id="985227">В тепловых пунктах должны быть установлены задвижки, отделяющие трубопроводы теплового пункта от тепловых сетей, и задвижки на каждом ответвлении от распределительных и сборных коллекторов.</div></div><div class="ACT_TEXT"><div name="985228" id="985228">5. Тепловые пункты следует оснащать средствами автоматизации, которые должны обеспечивать:</div></div><div class="ACT_TEXT"><div name="985230" id="985230">а) регулирование расхода тепловой энергии в системах теплопотребления (отопления, вентиляции и кондиционирования воздуха, в технологических установках);</div></div><div class="ACT_TEXT"><div name="985231" id="985231">б) ограничение максимального расхода сетевой воды у потребителей;</div></div><div class="ACT_TEXT"><div name="985232" id="985232">в) заданную температуру воды в системе горячего водоснабжения;</div></div><div class="ACT_TEXT"><div name="985233" id="985233">г) требуемое давление в системах теплопотребления при их независимом присоединении; заданное давление в обратном трубопроводе или требуемый перепад давления воды в подающем и обратном трубопроводах тепловых сетей;</div></div><div class="ACT_TEXT"><div name="985234" id="985234">д) защиту систем теплопотребления от повышенных давления и температуры воды в случае превышения допустимых предельных параметров теплоносителя;</div></div><div class="ACT_TEXT"><div name="985235" id="985235">е) включение резервных насосов при отключении рабочих; </div></div><div class="ACT_TEXT"><div name="985236" id="985236">ж) прекращение подачи воды в бак-аккумулятор при достижении верхнего уровня в нем и прекращение разбора воды из бака при достижении нижнего уровня; </div></div><div class="ACT_TEXT"><div name="985237" id="985237">з) предотвращение опорожнения систем теплопотребления.</div></div><div class="ACT_TEXT"><div name="985238" id="985238">6. В тепловых пунктах водяных тепловых сетей должны быть смонтированы устройства для выпуска воздуха из высших точек всех трубопроводов и для спуска воды из низших точек трубопроводов воды и конденсата.</div></div><div class="ACT_TEXT"><div name="985239" id="985239">7. На подающем трубопроводе при входе в тепловой пункт, на обратном трубопроводе перед регулирующими устройствами и приборами учета расходов воды и тепловой энергии должны быть смонтированы устройства (грязевики) для механической очистки сетевой воды от взвешенных частиц.</div></div><div class="ACT_TEXT"><div name="985240" id="985240">8. В тепловых пунктах не должно быть перемычек между подающим и обратным трубопроводами и обводных трубопроводов элеваторов, регулирующих клапанов, грязевиков и приборов для учета расходов теплоносителя и тепловой энергии.</div></div><div class="ACT_TEXT"><div name="985242" id="985242">Допускается устройство в ЦТП перемычек между подающим и обратным трубопроводами при обязательной установке на них двух последовательно расположенных задвижек (вентилей). Между этими задвижками (вентилями) должно быть выполнено дренажное устройство, соединенное с атмосферой. Арматура на перемычках в нормальных условиях эксплуатации должна быть закрыта и опломбирована.</div></div><div class="ACT_TEXT"><div name="985243" id="985243">Конденсатоотводники должны иметь отводные трубопроводы с установленной на них запорной арматурой.</div></div><div class="ACT_TEXT"><div name="985244" id="985244">9. В закрытых системах теплоснабжения на ЦТП предприятия на обводе задвижки обратного трубопровода допускается установка водомера для контроля плотности тепловой сети.</div></div><div class="ACT_TEXT"><div name="985245" id="985245">10. Тепловые узлы должны быть оборудованы штуцерами с задвижками (вентилями), к которым возможно присоединение линий водопровода и сжатого воздуха для промывки и опорожнения систем теплопотребления. В период нормальной эксплуатации линия водопровода от теплового узла должна быть отсоединена.</div></div><div class="ACT_TEXT"><div name="985246" id="985246">Соединение дренажных устройств с канализацией должно выполняться с видимым разрывом.</div></div><div class="ACT_TEXT"><div name="985247" id="985247">11. Тепловые пункты паровых систем теплопотребления, в которых расчетное давление пара ниже, чем давление в паропроводе, должны оборудоваться регуляторами давления (редукционными клапанами). После редукционного клапана на паропроводе должен быть установлен предохранительный клапан.</div></div><div class="ACT_TEXT"><div name="985248" id="985248">12. В тепловом пункте паровой системы теплопотребления должны быть оборудованы пусковые и эксплуатационные дренажные устройства.</div></div><div class="ACT_TEXT"><div name="985250" id="985250">13. ЦТП водяной системы теплопотребления должен быть оборудован следующими контрольно-измерительными приборами:</div></div><div class="ACT_TEXT"><div name="985251" id="985251">показывающими манометрами на подающем и обратном трубопроводах до и после входных задвижек, на каждом подающем трубопроводе после задвижек на распределительном коллекторе, на всасывающих и нагнетательных патрубках каждого насоса; </div></div><div class="ACT_TEXT"><div name="985253" id="985253">показывающими термометрами на общих подающих и обратных трубопроводах, на всех обратных трубопроводах перед сборными и обратными коллекторами;</div></div><div class="ACT_TEXT"><div name="985254" id="985254">регистрирующими расходомерами и термометрами на подающем и обратном трубопроводах; </div></div><div class="ACT_TEXT"><div name="985255" id="985255">приборами учета расхода тепловой энергии.</div></div><div class="ACT_TEXT"><div name="985256" id="985256">14. ИТП водяной системы теплопотребления должен быть оборудован следующими контрольно-измерительными приборами:</div></div><div class="ACT_TEXT"><div name="985257" id="985257">показывающими манометрами на подающем и обратном трубопроводах после задвижек;</div></div><div class="ACT_TEXT"><div name="985258" id="985258">показывающими термометрами на подающем и обратном трубопроводах после входных задвижек, на подающем трубопроводе смешанной воды после элеватора или смесительного насоса;</div></div><div class="ACT_TEXT"><div name="985260" id="985260">расходомерами на трубопроводе, подающем воду в систему горячего водоснабжения, и на циркуляционной линии (в открытых системах теплоснабжения).</div></div><div class="ACT_TEXT"><div name="985261" id="985261">Кроме того, ИТП водяной системы теплопотребления должен быть оборудован: штуцерами для манометров на подающем и обратном трубопроводах до задвижек, на всех ответвлениях подающего трубопровода после задвижек и после смесительного устройства;</div></div><div class="ACT_TEXT"><div name="985263" id="985263">гильзами для термометров на всех обратных трубопроводах от отдельных теплоиспользующих систем или отдельных частей этих систем до задвижек.</div></div><div class="ACT_TEXT"><div name="985264" id="985264">15. Тепловые пункты паровой системы теплопотребления должны быть оборудованы следующими контрольно-измерительными приборами:</div></div><div class="ACT_TEXT"><div name="985265" id="985265">регистрирующими и суммирующими расходомерами пара;</div></div><div class="ACT_TEXT"><div name="985266" id="985266">регистрирующими и показывающими манометрами и термометрами на вводных паропроводах;</div></div><div class="ACT_TEXT"><div name="985267" id="985267">суммирующими расходомерами, показывающими манометрами и термометрами на конденсатопроводах;</div></div><div class="ACT_TEXT"><div name="985268" id="985268">показывающими манометрами и термометрами до и после редукционных клапанов.</div></div><div class="ACT_TEXT"><div name="985271" id="985271">16. В случае отсутствии надежно действующих приборов автоматики и контроля в тепловых пунктах промышленных предприятий и организаций их обслуживание должно производиться круглосуточно. Все параметры теплоносителей должны фиксироваться в специальном журнале или ведомости. Все оперативные переключения, нарушения режима и аварийные случаи фиксируются в журнале дежурного, который должен ежедневно просматриваться и визироваться главным энергетиком (механиком) или начальником цеха.</div></div><div class="ACT_TEXT"><div name="985272" id="985272">17. При наличии на тепловом пункте конденсатосборников, устройств по очистке конденсата, а также контроля за его качеством следует руководствоваться <a href="/acts/973665#983635">параграфом 5 </a>главы III настоящих Правил. </div></div><div class="ACT_TEXT"><div name="985273" id="985273">18. При эксплуатации тепловых пунктов в системах теплопотребления должны осуществляться:</div></div><div class="ACT_TEXT"><div name="985274" id="985274">включение и отключение систем теплопотребления, подключенных на тепловом пункте;</div></div><div class="ACT_TEXT"><div name="985275" id="985275">контроль за работой оборудования;</div></div><div class="ACT_TEXT"><div name="985276" id="985276">обеспечение требуемыми режимными картами расходов пара и сетевой воды;</div></div><div class="ACT_TEXT"><div name="985277" id="985277">обеспечение требуемыми производственными инструкциями и режимными картами параметров пара и сетевой воды, поступающих на теплоиспользующие установки, конденсата и обратной сетевой воды, возвращаемых ими в тепловую сеть;</div></div><div class="ACT_TEXT"><div name="985278" id="985278">регулирование отпуска тепловой энергии на отопительно-вентиляционные нужды в зависимости от метеоусловий, а также на нужды горячего водоснабжения в соответствии с санитарными и технологическими нормами;</div></div><div class="ACT_TEXT"><div name="985279" id="985279">снижение удельных расходов сетевой воды и утечек ее из системы, сокращение технологических потерь тепловой энергии;</div></div><div class="ACT_TEXT"><div name="985280" id="985280">обеспечение надежной и экономичной работы всего оборудования теплового пункта;</div></div><div class="ACT_TEXT"><div name="985281" id="985281">поддержание в работоспособном состоянии средств контроля, учета и регулирования.</div></div><div class="ACT_TEXT"><div name="985282" id="985282">19. ЦТП должны иметь технический паспорт, где необходимо указывать все данные об оборудовании, схеме присоединения и нагрузке потребителей тепловой энергии.</div></div><div class="ACT_TEXT"><div name="985283" id="985283">20. Водо-водяные подогреватели систем отопления и горячего водоснабжения, установленные на тепловых пунктах, должны испытываться пробным давлением воды, равным 1,25 рабочего давления теплоносителя, но не менее 1 МПа (10 кгс/см<sup>2</sup>) со стороны межтрубного пространства при снятых передних и задних крышках (для секционных теплообменников-калачей).</div></div><div class="ACT_TEXT"><div name="985284" id="985284">21. Распределение пара по отдельным системам теплопотребления должно осуществляться настройкой регуляторов давления, а у потребителей с постоянным расходом пара — установкой дроссельных диафрагм соответствующих диаметров.</div></div><div class="BY_DEFAULT"><div name="985285" id="985285"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985286" id="985286">ПРИЛОЖЕНИЕ № 7 <br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации<br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985287" id="985287">Технические требования при эксплуатации баки-аккумуляторов </div></div><div class="BY_DEFAULT"><div name="985288" id="985288"></div></div><div class="ACT_TEXT"><div name="985289" id="985289">1. Баки-аккумуляторы должны быть оборудованы:</div></div><div class="ACT_TEXT"><div name="985305" id="985305">трубопроводом подачи воды в бак с поплавковым клапаном. Перед каждым поплавковым клапаном необходимо устанавливать запорную арматуру;</div></div><div class="ACT_TEXT"><div name="985306" id="985306">отводящим трубопроводом;</div></div><div class="ACT_TEXT"><div name="985307" id="985307">переливной трубой на высоте предельно допустимого уровня воды в баке. Пропускная способность переливной трубы должна быть не менее пропускной способности всех труб, подводящих воду к баку;</div></div><div class="ACT_TEXT"><div name="985308" id="985308">спускным (дренажным) трубопроводом, присоединенным к днищу бака и к переливной трубе, с задвижкой (вентилем) на присоединяемом участке трубопровода;</div></div><div class="ACT_TEXT"><div name="985309" id="985309">водоотводным трубопроводом для отвода воды из поддона;</div></div><div class="ACT_TEXT"><div name="985310" id="985310">циркуляционным трубопроводом для поддержания при необходимости постоянной температуры горячей воды в баке во время перерывов в ее разборе. На циркуляционном трубопроводе должен быть установлен обратный клапан с задвижкой (вентилем);</div></div><div class="ACT_TEXT"><div name="985311" id="985311">воздушной (вестовой) трубой. Сечение вестовой трубы должно обеспечивать свободное поступление в бак и свободное удаление из него воздуха или пара (при наличии паровой подушки), исключающие образование разрежение (вакуума) при откачке воды из бака и повышение давления выше атмосферного при его заполнении;</div></div><div class="ACT_TEXT"><div name="985312" id="985312">аппаратурой для контроля за уровнем воды, сигнализацией предельных уровней с выводом сигналов в помещение с постоянным пребыванием дежурного персонала, а также с блокировками, которые должны обеспечивать:</div></div><div class="ACT_TEXT"><div name="985313" id="985313">полное прекращение подачи воды в бак при достижении предельного верхнего уровня, включение резервных откачивающих насосов при отключении рабочих насосов, переключение основного источника электропитания оборудования, связанного с баками-аккумуляторами, на резервный при исчезновении напряжения на основном источнике;</div></div><div class="ACT_TEXT"><div name="985314" id="985314">контрольно-измерительными приборами для измерения температуры воды в баках и давления в подводящих и отводящих трубопроводах;</div></div><div class="ACT_TEXT"><div name="985315" id="985315">тепловой изоляцией, защищенной покровным слоем от воздействия атмосферных факторов.</div></div><div class="ACT_TEXT"><div name="985317" id="985317">2. Все трубопроводы, за исключением дренажного, должны подсоединяться к вертикальным стенкам баков-аккумуляторов с установкой компенсирующих устройств на расчетную осадку бака. Конструктивные решения по подключению трубопроводов к баку должны исключать возможность передачи усилия от этих трубопроводов на его стенки и днище.</div></div><div class="ACT_TEXT"><div name="985318" id="985318">3. Задвижки на трубопроводе подвода воды к каждому баку и разделительные задвижки между баками должны иметь электропривод. Электроприводы задвижек должны быть размещены вне зоны возможного затопления таким образом, чтобы в случае аварии на одном из баков было обеспечено оперативное отключение от него других параллельно работающих баков.</div></div><div class="ACT_TEXT"><div name="985319" id="985319">4. Во избежание неравномерности осадки песчаного основания баков должны быть предусмотрены устройства для удаления поверхностных и грунтовых вод.</div></div><div class="ACT_TEXT"><div name="985320" id="985320">5. Гидравлическое испытание баков-аккумуляторов осуществляется путем заполнения их водой до уровня, предусмотренного проектом. Во время заполнения бака необходимо наблюдать за состоянием его конструкций и сварных соединений. При обнаружении течи из-под днища или появлении мокрых пятен на поверхности отмостки следует прекратить испытания, слить воду, установить и устранить причину течи. Бак считается выдержавшим испытания, если по истечении 24 ч на его поверхности или по краям днища не обнаружено течи и уровень воды в баке не снижался.</div></div><div class="ACT_TEXT"><div name="985321" id="985321">Выявленные во время испытаний мелкие дефекты должны быть устранены, а места, где они были обнаружены, проверены на герметичность до ввода бака в эксплуатацию.</div></div><div class="ACT_TEXT"><div name="985323" id="985323">6. Баки-аккумуляторы должны быть заполнены только деаэрированной водой температурой не выше 95° С. Вновь смонтированные баки, а также баки после ремонта и внутреннего осмотра должны заполняться водой температурой не выше 45° С при температуре наружного воздуха не ниже минус 10° С.</div></div><div class="ACT_TEXT"><div name="985324" id="985324">Скорость заполнения баков водой должна соответствовать пропускной способности вестовой трубы.</div></div><div class="ACT_TEXT"><div name="985327" id="985327">7. Не допускается эксплуатация баков-аккумуляторов без антикоррозионной защиты внутренней поверхности.</div></div><div class="ACT_TEXT"><div name="985328" id="985328">8. Предельный уровень заполнения баков-аккумуляторов, запроектированных без тепловой изоляции, при наложении изоляции должен быть снижен на высоту, эквивалентную массе тепловой изоляции, которая должна быть нанесена на бак-аккумулятор.</div></div><div class="ACT_TEXT"><div name="985329" id="985329">В случае, когда в качестве бака-аккумулятора горячей воды был применен бак для нефтепродуктов, рассчитанный на плотность продукта 0,9 т/м<sup>3</sup>, его рабочий объем должен быть уменьшен на 10%.</div></div><div class="ACT_TEXT"><div name="985330" id="985330">9. Инструментальное обследование конструкций бака-аккумулятора с определением толщины стенок необходимо проводить не реже 1 раза в 3 года. При коррозионном износе стен и днища бака на 20% их проектной толщины и более дальнейшая эксплуатация бака независимо от характера износа и размера площади, подвергшейся коррозии, запрещается.</div></div><div class="ACT_TEXT"><div name="985331" id="985331">10. Наружный осмотр баков-аккумуляторов необходимо проводить ежедневно, обращая внимание на состояние тепловой изоляции подводящих и отводящих трубопроводов, компенсирующих устройств и т. п., а также на отсутствие течей. Обнаруженные дефекты должны быть немедленно устранены, а если это не представляется возможным, работа бака должна быть остановлена. </div></div><div class="ACT_TEXT"><div name="985332" id="985332">Электрическая схема сигнализации на баке должна опробоваться ежесменно с записью в оперативном журнале.</div></div><div class="BY_DEFAULT"><div name="985333" id="985333"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985334" id="985334">ПРИЛОЖЕНИЕ № 8<br />к <a href="/acts/973665#982707">Правилам </a>технической эксплуатации теплоиспользующих <br />установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985335" id="985335">Технические требования при эксплуатации водоподогревательных установок</div></div><div class="BY_DEFAULT"><div name="985336" id="985336"></div></div><div class="ACT_TEXT"><div name="985337" id="985337">1. На конденсатопроводах от подогревателей за конденсатоотводчиками должны быть установлены точки отбора проб для контроля за качеством конденсата, а также предусмотрено отключение подогревателя от общей схемы сбора конденсата при неудовлетворительном качестве конденсата.</div></div><div class="ACT_TEXT"><div name="985338" id="985338">2. Суммарная производительность перекачивающих насосов водоподогревательной установки должна обеспечивать расчетный гидравлический режим и производительность с учетом летнего режима работы. Количество насосов должно быть не менее двух. При одновременной работе нескольких насосов их характеристики должны допускать параллельную работу.</div></div><div class="ACT_TEXT"><div name="985339" id="985339">Насосы со стороны нагнетания должны иметь запорные задвижки и обратные клапаны.</div></div><div class="ACT_TEXT"><div name="985340" id="985340">3. Водоподогревательная установка должна быть оборудована следующей основной контрольно-измерительной аппаратурой:</div></div><div class="ACT_TEXT"><div name="985341" id="985341">а) манометрами — на паропроводах, на всасывающих и нагнетательных линиях насосов, на входящих и выходящих трубопроводах греющей и подогреваемой воды;</div></div><div class="ACT_TEXT"><div name="985342" id="985342">б) термометрами — на паропроводах и конденсатопроводах, на входящих и выходящих трубопроводах греющей и подогреваемой воды каждого подогревателя, на общих трубопроводах холодной и горячей воды;</div></div><div class="ACT_TEXT"><div name="985343" id="985343">в) расходомерами или водомерами — на трубопроводах первичного и вторичного теплоносителей;</div></div><div class="BY_DEFAULT"><div name="1745910" id="1745910"></div></div><div class="ACT_TEXT"><div name="1745911" id="1745911">г) предохранительными клапанами в соответствии с требованием Правил Государственной инспекции «Саноатгеоконтехназорат»;</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745913" id="1745913">(подпункт «г» пункта 3 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745310">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="985345" id="985345">д) дренажными устройствами для дренирования и удаления воздуха;</div></div><div class="ACT_TEXT"><div name="985346" id="985346">е) водоуказательным стеклом на стороне конденсирующего теплоносителя.</div></div><div class="ACT_TEXT"><div name="985347" id="985347">4. Для поддержания расчетного коэффициента теплопередачи поверхностей теплообменника последний периодически должен подвергаться химической или механической очистке.</div></div><div class="BY_DEFAULT"><div name="1745917" id="1745917"></div></div><div class="ACT_TEXT"><div name="1745919" id="1745919">5. Подогреватели после капитального и текущего ремонтов должны подвергаться проверке на плотность путем гидравлического испытания по нормам правил Государственной инспекции «Саноатгеоконтехназорат».</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745920" id="1745920">(пункт 5 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745310">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="985349" id="985349">6. Подогреватели во время их эксплуатации должны периодически, не реже одного раза в три месяца, подвергаться рабочей проверке на плотность под давлением водопровода или теплоносителя. В этом случае плотность определяется путем химического анализа воды (конденсата) или показанием манометра, термометра.</div></div><div class="ACT_TEXT"><div name="985350" id="985350">Результаты проверки должны быть зафиксированы в ремонтном журнале.</div></div><div class="ACT_TEXT"><div name="985351" id="985351">7. При обнаружении течи в вальцовке или в самих трубках водонагреватель должен быть остановлен на ремонт.</div></div><div class="ACT_TEXT"><div name="985352" id="985352">Установка заглушек на место поврежденной трубки может быть допущена лишь в исключительных случаях и в качестве временной меры.</div></div><div class="ACT_TEXT"><div name="985353" id="985353">8. Помимо проверки на плотность, все подогреватели должны подвергаться тепловым испытаниям на производительность не реже одного раза в 5 лет.</div></div><div class="ACT_TEXT"><div name="985354" id="985354">9. Водоподогревательная установка должна быть оборудована автоматическим регулятором температуры, обеспечивающим температуру воды, в соответствии с заданным режимом.</div></div><div class="ACT_TEXT"><div name="985355" id="985355">Для систем горячего водоснабжения температура воды должна быть в пределах (60—75° С).</div></div><div class="ACT_TEXT"><div name="985356" id="985356">10. Ремонт водоподогревательной установки и всех вспомогательных устройств должен производиться ежегодно в соответствии с графиком, увязанным со сроками теплового оборудования и теплопроводов системы теплоснабжения</div></div><div class="BY_DEFAULT"><div name="985357" id="985357"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985358" id="985358">ПРИЛОЖЕНИЕ № 9<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации теплоиспользующих <br />установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985359" id="985359">Технические требования при эксплуатации систем сбора и возврата конденсата</div></div><div class="BY_DEFAULT"><div name="985360" id="985360"></div></div><div class="ACT_TEXT"><div name="985361" id="985361">1. Качество производственного конденсата, используемого для питания котлов, должно быть таким, чтобы его смесь с другими составляющими соответствовала нормам питательной воды данного источника теплоснабжения.</div></div><div class="ACT_TEXT"><div name="985362" id="985362">В конденсате, возвращаемом на электростанции и котельные, должны отсутствовать продукты производства.</div></div><div class="ACT_TEXT"><div name="985363" id="985363">2. Избыточное давление в сборных баках конденсата при закрытых системах сбора и возврата конденсата должно быть не менее 0,005 МПа (0,05 кгс/см<sup>2</sup>).</div></div><div class="ACT_TEXT"><div name="985364" id="985364">3. На предприятиях с большим количеством пароприемников, разбросанных на большой территории, помимо центральной конденсатосборной станции, могут сооружаться специальные конденсатосборные подстанции.</div></div><div class="ACT_TEXT"><div name="985365" id="985365">На каждой станции и подстанции должно быть установлено не менее 2 конденсатных баков. Емкость конденсатных баков на конденсатосборных станциях и подстанциях определяется, исходя из 30-минутного количества поступающего конденсата. При автоматизации откачки конденсата емкость сборных баков может быть снижена до 15-минутного поступления. Баки систем сбора конденсата должны быть цилиндрической формы со сферическими днищами. Внутренняя поверхность баков сбора конденсата должна иметь антикоррозийное покрытие.</div></div><div class="ACT_TEXT"><div name="985366" id="985366">Применение баков прямоугольной формы в качестве конденсатосборников запрещается. Применение таких баков разрешается только для отстоя конденсата, когда возможность появления избыточного давления по условиям эксплуатации исключается.</div></div><div class="ACT_TEXT"><div name="985367" id="985367">Емкость баков замасленного конденсата должна обеспечивать возможность качественного его отстоя.</div></div><div class="ACT_TEXT"><div name="985368" id="985368">4. Сборные конденсатные баки должны быть оборудованы:</div></div><div class="ACT_TEXT"><div name="985369" id="985369">а) водоуказательными приборами;</div></div><div class="ACT_TEXT"><div name="985370" id="985370">б) сигнализацией верхнего и нижнего уровня или дистанционными указателями уровня;</div></div><div class="ACT_TEXT"><div name="985371" id="985371">в) термометрами для измерения температуры конденсата в баке;</div></div><div class="ACT_TEXT"><div name="985372" id="985372">г) мановакуумметрами для контроля за поддержанием избыточного давления в баке;</div></div><div class="ACT_TEXT"><div name="985373" id="985373">д) штуцерами с кранами и холодильниками для отбора проб конденсата;</div></div><div class="ACT_TEXT"><div name="985374" id="985374">е) предохранительными устройствами от повышения давления внутри бака;</div></div><div class="ACT_TEXT"><div name="985375" id="985375">ж) постоянными металлическими лестницами снаружи и при высоте бака более 1500 мм — постоянными лестницами внутри бака.</div></div><div class="ACT_TEXT"><div name="985376" id="985376">При открытых системах конденсатные баки дополнительно должны быть оборудованы устройствами для сообщения их с атмосферой.</div></div><div class="ACT_TEXT"><div name="985377" id="985377">На вновь вводимых в эксплуатацию предприятиях, а также при реконструкции, системы сбора конденсата должны быть закрытого типа.</div></div><div class="ACT_TEXT"><div name="985378" id="985378">5. Система сбора конденсата должна допускать отключение бака без нарушения нормальной эксплуатации теплоиспользующих установок.</div></div><div class="ACT_TEXT"><div name="985379" id="985379">6. Количество насосов на конденсатосборной станции или подстанции должно быть не менее двух. Характеристики насосов должны допускать их параллельную работу.</div></div><div class="ACT_TEXT"><div name="985380" id="985380">При наличии потребления пара на отопление и вентиляцию каждый насос выбирается на 60%, а для технологических потребителей на 100% максимальной величины возвращаемого конденсата.</div></div><div class="ACT_TEXT"><div name="985381" id="985381">7. Перекачивающие насосы системы сбора и возврата конденсата должны иметь порядковые номера и при наличии нескольких перекачивающих подстанций нумерация их не должна повторяться.</div></div><div class="ACT_TEXT"><div name="985382" id="985382">Разность отметок между уровнем конденсата в сборном баке и осью насоса должна быть достаточной для предупреждения вскипания среды во всасывающем патрубке насоса при максимальной температуре конденсата, но не менее 0,5 м.</div></div><div class="ACT_TEXT"><div name="985383" id="985383">8. Конденсатные насосы, работающие на общий конденсатопровод, на всасывающих линиях должны быть установлены задвижки, а со стороны нагнетания — задвижки и обратные клапаны. Работа насосов при неисправных или отключенных обратных клапанах не допускается.</div></div><div class="ACT_TEXT"><div name="985384" id="985384">9. Конденсатные станции должны располагаться в помещении, выполненном по проекту в соответствии с действующими нормами и Правилами.</div></div><div class="ACT_TEXT"><div name="985385" id="985385">Каждая станция и подстанция должны иметь электрическое освещение и вентиляцию. </div></div><div class="ACT_TEXT"><div name="985386" id="985386">Помещение станции должно запираться.</div></div><div class="ACT_TEXT"><div name="985387" id="985387">При сооружении конденсатосборных станций или подстанций в подвальных помещениях или в местах, подверженных затоплению грунтовыми или сточными водами, должна быть выполнена надежная гидроизоляция и соответствующие дренажные устройства. Конденсатные баки, конденсатопроводы и другое теплофикационное оборудование конденсатной станции или подстанции должно иметь тепловую изоляцию.</div></div><div class="ACT_TEXT"><div name="985388" id="985388">10. Для наблюдения за эксплуатацией систем сбора конденсата должен производиться систематический контроль за количеством, качеством, давлением и температурой возвращаемого конденсата.</div></div><div class="ACT_TEXT"><div name="985389" id="985389">Периодичность контроля и анализов конденсата согласовывается в каждом отдельном случае с энергоснабжающей организацией (цехом).</div></div><div class="ACT_TEXT"><div name="985390" id="985390">При этом периодичность должна быть такой, чтобы исключить возможность попадания некачественного конденсата на источник тепловой энергии.</div></div><div class="ACT_TEXT"><div name="985391" id="985391">11. Для осуществления контроля за работой систем сбора конденсата конденсатоперекачивающая установка должна быть оборудована:</div></div><div class="ACT_TEXT"><div name="985392" id="985392">а) манометрами для измерения давления в сборном конденсатопроводе, перед и после перекачивающего насоса;</div></div><div class="ACT_TEXT"><div name="985393" id="985393">б) приборами для измерения температуры перекачиваемого конденсата;</div></div><div class="ACT_TEXT"><div name="985394" id="985394">в) расходомером или водомером для измерения количества перекачиваемого конденсата;</div></div><div class="ACT_TEXT"><div name="985395" id="985395">г) штуцерами с кранами и холодильниками для отбора проб конденсата;</div></div><div class="ACT_TEXT"><div name="985396" id="985396">д) автоматическими приборами в зависимости от требования, предъявляемых к данному потребителю энергоснабжающей организацией (цехом).</div></div><div class="ACT_TEXT"><div name="985397" id="985397">12. Для защиты систем сбора и возврата конденсата от коррозии должны осуществляться:</div></div><div class="ACT_TEXT"><div name="985398" id="985398">а) закрытые системы сбора конденсата;</div></div><div class="ACT_TEXT"><div name="985399" id="985399">б) ввод конденсата снизу сборных баков;</div></div><div class="ACT_TEXT"><div name="985400" id="985400">в) непрерывная откачка конденсата;</div></div><div class="ACT_TEXT"><div name="985401" id="985401">г) полное постоянное заполнение сечения конденсатопроводов;</div></div><div class="ACT_TEXT"><div name="985402" id="985402">д) поддержание избыточного давления в конденсатосборнике.</div></div><div class="ACT_TEXT"><div name="985404" id="985404">В целях улучшения эксплуатации системы сбора и возврата конденсата, удаления конденсата из паропроводов и теплоиспользующих установок откачка конденсата из сборных баков и защита конденсатопроводов от опорожения должны быть автоматизированы.</div></div><div class="ACT_TEXT"><div name="985406" id="985406">13. Для предотвращения попадания конденсата из общего конденсатопровода в сборные баки параллельно работающих потребителей пара конденсатопроводы каждого потребителя должны быть оснащены обратными клапанами.</div></div><div class="ACT_TEXT"><div name="985407" id="985407">14. Приемка в эксплуатацию системы сбора и возврата конденсата должна производиться после гидравлического испытания и промывки ее.</div></div><div class="ACT_TEXT"><div name="985408" id="985408">Промывка конденсатопроводов считается законченной после получения конденсата удовлетворительного качества, подтвержденного химическими анализами. Отбор проб конденсата до анализа должен производиться из сборных баков и в местах спуска конденсата в дренаж.</div></div><div class="ACT_TEXT"><div name="985409" id="985409">15. Сборные баки конденсата закрытого типа следует испытывать на плотность и прочность давлением, равным 1,5 рабочего, но не менее 0,3 МПа (3 кгс/см<sup>2</sup>).</div></div><div class="ACT_TEXT"><div name="985410" id="985410">Для контроля плотности и прочности открытых баков производится наполнение их водой.</div></div><div class="BY_DEFAULT"><div name="985411" id="985411"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985412" id="985412">ПРИЛОЖЕНИЕ № 10 <br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985413" id="985413">Технические требования при эксплуатации теплоиспользующих установок </div></div><div class="BY_DEFAULT"><div name="985414" id="985414"></div></div><div class="ACT_TEXT"><div name="985415" id="985415">1. Теплоиспользующие установки должны иметь:</div></div><div class="ACT_TEXT"><div name="985416" id="985416">а) лестницы и площадки, обеспечивающие доступ к основным элементам и контрольно-измерительным приборам, требующим обслуживания и систематического осмотра;</div></div><div class="ACT_TEXT"><div name="985417" id="985417">б) запорную арматуру на линиях входа и выхода греющей и нагреваемой среды;</div></div><div class="BY_DEFAULT"><div name="1745921" id="1745921"></div></div><div class="ACT_TEXT"><div name="1745923" id="1745923">в) предохранительные клапаны в соответствии с правилами Государственной инспекции «Саноатгеоконтехназорат»;</div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745924" id="1745924">(подпункт «в» пункта 1 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745310">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="985419" id="985419">г) смотровые и водоуказательные стекла в тех случаях, когда должно производиться наблюдение за уровнем или состоянием жидкости или массы в установке;</div></div><div class="ACT_TEXT"><div name="985420" id="985420">д) устройства для отбора проб и удаления воздуха, газов, технологических продуктов и конденсата;</div></div><div class="ACT_TEXT"><div name="985421" id="985421">е) манометры и термометры для измерения давления и температуры теплоносителя и нагреваемой среды;</div></div><div class="ACT_TEXT"><div name="985422" id="985422">ж) приборы учета расхода теплоносителя и тепловой энергии;</div></div><div class="ACT_TEXT"><div name="985423" id="985423">з) другие приборы и автоматику, предусмотренные проектом.</div></div><div class="ACT_TEXT"><div name="985424" id="985424">2. В тех случаях, когда теплоиспользующие установки рассчитаны на давление ниже давления источника теплоснабжения, должно быть предусмотрено устройство для понижения давления, а при необходимости и температуры.</div></div><div class="ACT_TEXT"><div name="985425" id="985425">3. Отвод конденсата от пароиспользующей установки поверхностного типа должен осуществляться через автоматические конденсатоотводчики.</div></div><div class="ACT_TEXT"><div name="985426" id="985426">4. Давление и температура теплоносителя, подаваемого на теплоиспользующие установки, должны соответствовать значениям, установленным технологическим режимом. Пределы колебаний параметров теплоносителя должны быть указаны в инструкции по эксплуатации.</div></div><div class="ACT_TEXT"><div name="985427" id="985427">5. При поступлении в теплоиспользующие установки влажного пара, в случае необходимости его осушки, перед ними устанавливаются сепараторы.</div></div><div class="ACT_TEXT"><div name="985428" id="985428">6. Каждая теплоиспользующая установка должна иметь порядковый номер, четко обозначенный с фронта установки.</div></div><div class="ACT_TEXT"><div name="985429" id="985429">На запорной и регулирующей арматуре, а также на прилегающих участках теплопроводов и технологических трубопроводов должно быть отчетливо указано стрелкой направление движения теплоносителя и технологических растворов, условное обозначение их, номер арматуры по схеме, указатели открытия и закрытия арматуры.</div></div><div class="ACT_TEXT"><div name="985430" id="985430">7. Все внешние части теплоиспользующих установок и теплопроводы должны быть изолированы таким образом, чтобы температура поверхности изоляции не превышала 45<sup>o</sup> С при температуре окружающего воздуха 25<sup>o</sup> С. В случаях, когда по местным условиям металл теплоиспользующих установок под изоляцией может подвергаться разрушению, изоляция должна быть съемной.</div></div><div class="ACT_TEXT"><div name="985431" id="985431">8. При установке теплоиспользующих установок на открытом воздухе (вне здания) тепловая изоляция должна иметь гидроизоляционное покрытие.</div></div><div class="ACT_TEXT"><div name="985432" id="985432">9. Электродвигатели, вентиляторы, калориферы и другое вспомогательное оборудование должно иметь номер той установки, с которой они связаны технологическим процессом. При наличии у теплоиспользующей установки нескольких электродвигателей, вентиляторов и другого вспомогательного оборудования каждый из них должен иметь номер теплоиспользующей установки с добавлением порядковых индексов.</div></div><div class="ACT_TEXT"><div name="985433" id="985433">10. Вместе с теплоиспользующей установкой гидравлическому испытанию должны подвергаться относящиеся к ней арматура, трубопроводы и вспомогательное оборудование.</div></div><div class="ACT_TEXT"><div name="985434" id="985434">11. Теплоиспользующие установки или их части, предназначенные для работы под давлением менее 0,07 МПа (0,7 кгс/см<sup>2</sup> ) или под разрежением испытываются на прочность давлением 0,2 МПа (2 кгс/см<sup>2</sup>) и плотность давлением 0,15 МПа (1,5 кгс/см<sup>2</sup>).</div></div><div class="ACT_TEXT"><div name="985435" id="985435">12. Теплоиспользующие установки, у которых действие химической среды вызывает изменение состава и ухудшение механических свойств металла, а также теплоиспользующие установки с сильной коррозийной средой или температурой стенок свыше 475<sup>o</sup> С должны подвергаться дополнительным освидетельствованиям в соответствии со специальной инструкцией.</div></div><div class="ACT_TEXT"><div name="985436" id="985436">13. Внеочередные гидравлические испытания и внутренние осмотры теплоиспользующей установки должны производиться после капитального ремонта или реконструкции, а также при бездействии установки более 1 года.</div></div><div class="ACT_TEXT"><div name="985437" id="985437">14. Теплоиспользующие установки повышенной опасности, где снижение или повышение параметров теплоносителя может вызвать аварию или угрожать жизни людей, должны быть оборудованы приборами безопасности, обеспечивающими безаварийную работу теплопоребляющей установки, оборудования и ее элементов.</div></div><div class="ACT_TEXT"><div name="985438" id="985438">15. На теплоиспользующих установках запрещается применять и использовать манометры, у которых:</div></div><div class="ACT_TEXT"><div name="985439" id="985439">а) отсутствует пломба или клеймо;</div></div><div class="ACT_TEXT"><div name="985440" id="985440">б) просрочен срок поверки;</div></div><div class="ACT_TEXT"><div name="985441" id="985441">в) разбито стекло;</div></div><div class="ACT_TEXT"><div name="985442" id="985442">г) отсутствует красная черта или контрольная пластина, показывающая предельное допустимое рабочее давление;</div></div><div class="ACT_TEXT"><div name="985443" id="985443">д) стрелка манометра при его выключении не возвращается к нулевому показанию шкалы на величину, превышающую половину допускаемой погрешности для данного манометра, или имеются другие повреждения, которые могут отразиться на правильности его показаний.</div></div><div class="ACT_TEXT"><div name="985444" id="985444">16. Каждый манометр должен быть хорошо освещен, защищен от влияния лучистой теплоты и от замерзания. На линии, ведущей к манометру, запрещается производить подключение для отбора среды.</div></div><div class="ACT_TEXT"><div name="985445" id="985445">17. На каждой теплоиспользующей установке, работающей под давлением, после установки и регистрации должны быть на специальной табличке форматом не менее 200—150 мм нанесены следующие данные:</div></div><div class="ACT_TEXT"><div name="985446" id="985446">а) регистрационный номер;</div></div><div class="ACT_TEXT"><div name="985447" id="985447">б) допустимое давление;</div></div><div class="ACT_TEXT"><div name="985448" id="985448">в) дата (месяц и год) следующего внутреннего осмотра и гидравлического испытания. </div></div><div class="ACT_TEXT"><div name="985449" id="985449">Наносятся данные и по температуре, если она превышает 250<sup>o</sup> С.</div></div><div class="ACT_TEXT"><div name="985450" id="985450">18. Конструкция и состояние пусковых устройств (пусковых кнопок, рычагов ручного управления и др.) должны обеспечивать быстрое и надежное включение и отключение оборудования и участков теплопроводов и исключать возможность самопроизвольного срабатывания.</div></div><div class="ACT_TEXT"><div name="985451" id="985451">19. Конструкция и расположение аварийных выключателей и кнопок дистанционного управления оборудованием должны обеспечивать возможность пользования ими с различных рабочих позиций.</div></div><div class="ACT_TEXT"><div name="985452" id="985452">20. Все пусковые устройства должны иметь надписи, указывающие их назначение. На маховиках основных оперативных и аварийных задвижек и вентилей должны быть нанесены стрелки, указывающие направление вращения при открытии или закрытии.</div></div><div class="BY_DEFAULT"><div name="985541" id="985541"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985544" id="985544">ПРИЛОЖЕНИЕ № 11<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985546" id="985546">Технические требования при эксплуатации паровых молотов</div></div><div class="BY_DEFAULT"><div name="985547" id="985547"></div></div><div class="ACT_TEXT"><div name="985548" id="985548">1. Паровой молот, находящийся в эксплуатации, должен удовлетворять следующим основным условиям:</div></div><div class="ACT_TEXT"><div name="985549" id="985549">а) из цилиндра не должен выделяться пар;</div></div><div class="ACT_TEXT"><div name="985550" id="985550">б) нижняя полость цилиндра должна быть дренирована посредством паропускной трубки, оборудованной конденсатоотводчиком;</div></div><div class="ACT_TEXT"><div name="985551" id="985551">в) парозапорная арматура должна быть плотной и не допускать пропусков пара, а закрытом положении;</div></div><div class="ACT_TEXT"><div name="985552" id="985552">г) зазоры между поршнем и цилиндром, поршневыми кольцами и стенками ручьев поршня, золотником и золотниковой втулкой, дросселем и втулкой должны соответствовать величинам, указанных в инструкции по сборке и ремонту;</div></div><div class="ACT_TEXT"><div name="985559" id="985559">д) из выхлопной трубы не должно быть парения при открытом парозапорном вентиле и перекрытом золотнике;</div></div><div class="ACT_TEXT"><div name="985560" id="985560">е) сальник должен быть плотно набит просаленной и прографиченной набивкой, нормально затянут и не должен парить;</div></div><div class="ACT_TEXT"><div name="985561" id="985561">ж) движение педали и рукояток управления должно совершаться без чрезмерного усилия со стороны рабочего;</div></div><div class="ACT_TEXT"><div name="985563" id="985563">з) молот должен обеспечивать удары нормальной силы при заданном давлении пара;</div></div><div class="ACT_TEXT"><div name="985564" id="985564">и) все части молота должны быть собраны без перекосов и слабины в креплениях;</div></div><div class="ACT_TEXT"><div name="985565" id="985565">к) приборы для смазки должны действовать исправно;</div></div><div class="ACT_TEXT"><div name="985566" id="985566">л) устройство для отвода конденсата и предохранительные приспособления должны находиться в исправном состоянии;</div></div><div class="ACT_TEXT"><div name="985567" id="985567">м) отметки, фиксирующие крайние допустимые положения бабы, указатели при рукоятках, соответствующие крайним положениям золотника, должны быть выверены и четко обозначены.</div></div><div class="ACT_TEXT"><div name="985568" id="985568">2. Для отключения пара во время коротких остановок молота должны быть установлены поворотные плоские задвижки.</div></div><div class="ACT_TEXT"><div name="985569" id="985569">3. Работа парового молота на выхлоп не допускается.</div></div><div class="ACT_TEXT"><div name="985570" id="985570">4. Испытание молотов для определения часовых и удельных расходов пара и величин утечек должно производиться периодически, но не реже 1 раза в 3 года.</div></div><div class="ACT_TEXT"><div name="985571" id="985571">5. Наружные осмотры и опробование парораспределительного механизма должны производиться при каждой приемке и сдаче смены работающим на молоте персоналом и дополнительно не менее 1 раза в смену дежурным слесарем.</div></div><div class="ACT_TEXT"><div name="985574" id="985574">6. На паропроводах отработанного пара, идущих к водоподогревателям, должны быть предусмотрены устройства (выхлопные трубы) для поддержания заданного противодавления у паровых машин (молотов, прессов и т. п.), а также люки для очистки паропроводов.</div></div><div class="ACT_TEXT"><div name="985575" id="985575">Должна предусматриваться механическая очистка отработанного пара от масла до 10 мг/кг, обеспечивающая надежную работу теплоиспользующего оборудования. </div></div><div class="ACT_TEXT"><div name="985576" id="985576">7. Внутренний осмотр и частичная проверка золотников, парораспределительных клапанов, дросселей, задвижек и уплотнительных колец поршня должны производиться не реже одного раза в месяц.</div></div><div class="ACT_TEXT"><div name="985577" id="985577">8. Запрещается смазка внутренней части цилиндра путем заливки в цилиндр масла через отверстия в крышке.</div></div><div class="ACT_TEXT"><div name="985578" id="985578">9. Смазочные материалы, употребляемые для паровых молотов, должны применяться только кондиционные, предусмотренные КМК и ТУ.</div></div><div class="ACT_TEXT"><div name="985579" id="985579">10. Система смазки молота должна осматриваться, очищаться и продуваться не реже 1 раза в неделю.</div></div><div class="BY_DEFAULT"><div name="985581" id="985581"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985582" id="985582">ПРИЛОЖЕНИЕ № 12<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985583" id="985583">Технические требования при эксплуатации сушильных установок </div></div><div class="BY_DEFAULT"><div name="985584" id="985584"></div></div><div class="ACT_TEXT"><div name="985585" id="985585">1. Камеры сушилок должны быть герметичны. У дверей камер должны быть установлены рычажные, клиновые, винтовые или другие устройства, плотно закрывающие двери.</div></div><div class="ACT_TEXT"><div name="985586" id="985586">2. Если в конвейерных сушилках по условиям эксплуатации не могут быть устроены двери или конструкция сушилки не обеспечивает зону с нулевым давлением, у входа и выхода сушилки необходимо устраивать тепловые (воздушные) завесы.</div></div><div class="ACT_TEXT"><div name="985587" id="985587">3. Сушильные установки должны иметь тепловую изоляцию, обеспечивающую минимальные потери тепла; при установке сушилок на открытом воздухе теплоизоляция должна быть влагоустойчивой.</div></div><div class="ACT_TEXT"><div name="985589" id="985589">4. В сушильных установках, в которых происходит пропаривание материала или изделий, все ограждения должны покрываться слоем гидроизоляции.</div></div><div class="ACT_TEXT"><div name="985590" id="985590">5. Сушилки для взрывоопасных материалов должны быть снабжены взрывными клапанами. Трубы от клапанов должны быть выведены наружу, за пределы цеха.</div></div><div class="ACT_TEXT"><div name="985592" id="985592">6. Сушилки для ядовитых едких материалов должны устанавливаться в специальных изолированных помещениях. Загрузка и выгрузка их, как правило, должны быть механизированы.</div></div><div class="ACT_TEXT"><div name="985593" id="985593">7. Все сушилки (кроме конденсационных) должны быть обеспечены вытяжной вентиляцией.</div></div><div class="ACT_TEXT"><div name="985594" id="985594">8. При установке в сушилке на одном валу нескольких осевых вентиляторов для равномерной циркуляции воздуха должны устанавливаться на один вал с одной стороны вентиляторы правого, а с другой стороны — вентиляторы левого вращения или должен быть реверсивный привод.</div></div><div class="ACT_TEXT"><div name="985595" id="985595">9. В сушилках с принудительной циркуляцией воздуха должны устанавливаться ребристые или гладкотрубные подогреватели или пластинчатые калориферы. Для лучшего обеспечения стока конденсата пластинчатые калориферы должны устанавливаться вертикально. </div></div><div class="ACT_TEXT"><div name="985596" id="985596">10. Для обеспечения равномерного распределения воздуха в сушильной камере должны устанавливаться направляющие экраны, решетки и другие устройства. Не допускается сушка материалов в камерных сушилках с неполными габаритами штабеля по высоте.</div></div><div class="ACT_TEXT"><div name="985597" id="985597">11. При сушке порошкообразных или дробленых материалов должна производиться очистка удаляемого из сушилки воздуха путем устройства пылеосадочных камер, сухих или мокрых циклонов, мультициклонов, матерчатых фильтров или электрофильтров. В этих сушилках должна применяться рециркуляция воздуха.</div></div><div class="ACT_TEXT"><div name="985598" id="985598">Кратность рециркуляции воздуха должна быть определена расчетом по режиму сушки, по противопожарным нормам концентрации взрывоопасных паров и пыли, выделяемых при сушке, и указана в инструкции.</div></div><div class="ACT_TEXT"><div name="985599" id="985599">12. При обслуживании сушильную установку, на рабочем месте технологического персонала, должна быть режимная карта. В процессе эксплуатации сушилки должен вестись контроль за параметрами теплоносителя, регламентируемыми температурами по зонам, за качеством высушиваемого материала с регистрацией показателей в оперативном журнале. </div></div><div class="ACT_TEXT"><div name="985600" id="985600">13. Режим работы сушильных установок и установление характеристики работы основного и вспомогательного оборудования определяются эксплуатационными испытаниями, которые должны производиться:</div></div><div class="ACT_TEXT"><div name="985601" id="985601">а) после капитальных ремонтов сушилок;</div></div><div class="ACT_TEXT"><div name="985602" id="985602">б) после внесения конструктивных изменений или проведения рационализаторских мероприятий, требующих проверки;</div></div><div class="ACT_TEXT"><div name="985603" id="985603">в) для устранения неравномерности сушки, связанной с браком продукции.</div></div><div class="ACT_TEXT"><div name="985604" id="985604">14. При испытаниях сушилки должны определяться количество и параметры греющего теплоносителя, температура влажность сушильного воздуха в разных точках камеры, коэффициент теплопередачи нагревательных поверхностей, производительность и число оборотов вентиляторов и электродвигателей (в сушилках с принудительной циркуляцией воздуха).</div></div><div class="ACT_TEXT"><div name="985605" id="985605">15. Поверхность нагрева калориферов сушильных установок должна подвергаться периодической очистке.</div></div><div class="BY_DEFAULT"><div name="985606" id="985606"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985608" id="985608">ПРИЛОЖЕНИЕ № 13<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985609" id="985609">Технические требования при эксплуатации выпарных установок </div></div><div class="BY_DEFAULT"><div name="985610" id="985610"></div></div><div class="ACT_TEXT"><div name="985611" id="985611">1. Для подогрева раствора, поступающего в первый корпус, до температуры, близкой к температуре кипения, необходимо устанавливать перед первым корпусом специальные подогреватели, обогреваемые конденсатом или соковым паром.</div></div><div class="ACT_TEXT"><div name="985612" id="985612">2. Коммуникации подогревателей должны иметь запорные устройства для отключения и обводную линию у каждого подогревателя, а также должны иметь линию для возврата подогретого раствора в промежуточный бак (для осуществления циркуляции раствора через подогреватели) в периоды, когда первый корпус не может непрерывно принимать подогретый раствор.</div></div><div class="ACT_TEXT"><div name="985614" id="985614">3. Для контроля за непрерывным отводом конденсата, а также за его качеством на линии за конденсатоотводчиками устанавливаются смотровые стекла и пробные краны.</div></div><div class="ACT_TEXT"><div name="985616" id="985616">В зависимости от качества конденсата (по химическому составу и наличию примесей) он должен собираться от всех выпарных аппаратов вместе или раздельно.</div></div><div class="ACT_TEXT"><div name="985619" id="985619">Для непрерывного контроля качества конденсата должны устанавливаться сигнализирующие солемеры или другие приборы.</div></div><div class="ACT_TEXT"><div name="985620" id="985620">4. Для обеспечения наблюдений за уровнем раствора в выпарных аппаратах должны устанавливаться смотровые стекла.</div></div><div class="ACT_TEXT"><div name="985621" id="985621">5. Выпарные установки должны быть оснащены следующими контрольно-измерительными или регулирующими приборами:</div></div><div class="ACT_TEXT"><div name="985628" id="985628">а) автоматическими регуляторами давления пара, поступающего в первый корпус;</div></div><div class="ACT_TEXT"><div name="985629" id="985629">б) регистрирующим манометром на линии подачи пара в цех;</div></div><div class="ACT_TEXT"><div name="985630" id="985630">в) манометрами на греющей камере и в паровом пространстве первого корпуса: манометрами, вакуумметрами на греющих камерах и в паровом пространстве последующих корпусов;</div></div><div class="ACT_TEXT"><div name="985631" id="985631">г) автоматическими регуляторами уровня раствора;</div></div><div class="ACT_TEXT"><div name="985632" id="985632">д) указывающими и сигнализирующими вакуумметрами на трубопроводах, идущих от барометрических или поверхностных конденсаторов;</div></div><div class="ACT_TEXT"><div name="985633" id="985633">е) ртутными термометрами или термометрами сопротивления на всех выпарных аппаратах, подогревателях и барометрическом или поверхностном конденсаторе;</div></div><div class="ACT_TEXT"><div name="985634" id="985634">ж) расходомером для учета расхода воды, поступающей в цех;</div></div><div class="ACT_TEXT"><div name="985635" id="985635">з) расходомером для учета раствора, поступающего на выпарку;</div></div><div class="ACT_TEXT"><div name="985636" id="985636">и) концентратомерами после каждого выпарного аппарата.</div></div><div class="ACT_TEXT"><div name="985638" id="985638">6. Для обеспечения нормального режима работы выпарной установки необходимо:</div></div><div class="ACT_TEXT"><div name="985639" id="985639">а) следить за подачей греющего пара в первый корпус и не допускать падения или повышения давления греющего пара в значительных пределах (допустимыми считаются колебания в пределах 0,01 МПа (0,1 кгс/см<sup>2</sup>));</div></div><div class="ACT_TEXT"><div name="985640" id="985640">б) поддерживать предусмотренное технологическим процессом распределение температур и давлений по корпусам выпарной установки;</div></div><div class="ACT_TEXT"><div name="985641" id="985641">в) следить за непрерывным отводом конденсатов на греющих камерах выпарных аппаратов, а также систематически проверять качество конденсата;</div></div><div class="ACT_TEXT"><div name="985642" id="985642">г) обеспечить систематическое питание выпарных аппаратов раствором, подогретым до температуры, близкой к температуре кипения;</div></div><div class="ACT_TEXT"><div name="985643" id="985643">д) следить за нормальным перепуском растворов из корпуса в корпус и систематически выводить из последнего корпуса готовый продукт, поддерживая установленный уровень растворов, в аппаратах и не допуская оголения греющих камер;</div></div><div class="ACT_TEXT"><div name="985644" id="985644">е) обеспечивать минимальные потери растворов, концентратов и теплоносителей;</div></div><div class="ACT_TEXT"><div name="985646" id="985646">ж) поддерживать разрежение в выпарных аппаратах, работающих под вакуумом, на уровне, предусмотренном режимом и в случаях падения вакуума немедленно выявлять причины и устранять их; температуру воды, отходящей из барометрического конденсатора, поддерживать в пределах, заданных технологическим режимом;</div></div><div class="ACT_TEXT"><div name="985647" id="985647">з) не реже 1 раза в смену удалять через специальные вентили воздух из греющих камер;</div></div><div class="ACT_TEXT"><div name="985648" id="985648">и) строго соблюдать предусмотренный график и порядок промывки выпарных аппаратов, а при необходимости производить внеочередные промывки выпарных аппаратов и очистку их;</div></div><div class="ACT_TEXT"><div name="985649" id="985649">к) обеспечивать непрерывную и исправную работу автоматических приборов, теплоизмерительных и регулирующих приборов, арматуры, а также вспомогательного оборудования выпарной станции.</div></div><div class="ACT_TEXT"><div name="985651" id="985651">7. Схема трубопроводов выпарной установки должна исключать возможность смешения потоков греющего первичного и вторичного пара, а также потоков их конденсата.</div></div><div class="BY_DEFAULT"><div name="985652" id="985652"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985653" id="985653">ПРИЛОЖЕНИЕ № 14<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985654" id="985654">Технические требования при эксплуатации ректификационных установок </div></div><div class="BY_DEFAULT"><div name="985655" id="985655"></div></div><div class="ACT_TEXT"><div name="985656" id="985656">1. Ректификационные установки должны быть оборудованы теплообменниками (нагревательными устройствами) для подогрева поступающих в колонку жидкостей. Длина витков змеевиковых подогревателей должна быть, возможно более короткой для облегчения отвода конденсата.</div></div><div class="ACT_TEXT"><div name="985657" id="985657">2. Ректификационные установки должны быть оборудованы приспособлениями для конденсации выделяющих паров (конденсаторы, дефлегматоры). Для увеличения коэффициента теплопередачи одноходовые конденсаторы заменяются многоходовыми.</div></div><div class="ACT_TEXT"><div name="985658" id="985658">3. Ректификационные установки должны быть оборудованы мерниками или расходомерами для измерения количеств поступающих и отводимых продуктов.</div></div><div class="ACT_TEXT"><div name="985659" id="985659">4. В ректификационных установках должны быть установлены смотровые стекла для наблюдения и регулирования расхода проходящих продуктов.</div></div><div class="ACT_TEXT"><div name="985660" id="985660">5. Ректификационные установки должны быть оснащены следующими контрольно-измерительными приборами:</div></div><div class="ACT_TEXT"><div name="985661" id="985661">а) регистрирующими и суммирующими паромерами на линии подачи пара;</div></div><div class="ACT_TEXT"><div name="985662" id="985662">б) регистрирующими манометрами;</div></div><div class="ACT_TEXT"><div name="985663" id="985663">в) манометрами, вакуумметрами и термометрами для замеров давления и температуры в ректификационной установке;</div></div><div class="ACT_TEXT"><div name="985664" id="985664">г) термометрами на линиях, подводящих и отводящих воду из ректификационных установок;</div></div><div class="ACT_TEXT"><div name="985665" id="985665">д) термометрами, установленными в контрольном фонаре для измерения температуры перегоняемой смеси;</div></div><div class="ACT_TEXT"><div name="985666" id="985666">е) приборами автоматического контроля и дистанционного измерения температуры и давления (в первую очередь для аппаратов непрерывного действия);</div></div><div class="ACT_TEXT"><div name="985667" id="985667">ж) с холодильниками на конденсатопроводах от них.</div></div><div class="ACT_TEXT"><div name="985669" id="985669">6. Ректификационные аппараты, работающие под вакуумом, кроме приборов, указанных в <a href="/acts/973665#985660">п. 5</a> приложения № 14 настоящих Правил должны быть оборудованы:</div></div><div class="ACT_TEXT"><div name="985670" id="985670">а) регулятором вакуума для предохранения системы от значительных его колебаний;</div></div><div class="ACT_TEXT"><div name="985671" id="985671">б) промежуточным цилиндром для предохранения вакуум-насоса от попадания в него жидкости;</div></div><div class="ACT_TEXT"><div name="985672" id="985672">в) каплеуловителем для задерживания капель дистиллята, содержащихся в паре.</div></div><div class="ACT_TEXT"><div name="985673" id="985673">7. Для обеспечения нормального режима ректификационной установки необходимо:</div></div><div class="ACT_TEXT"><div name="985674" id="985674">а) обеспечить контроль за работой паровых регуляторов, не допуская колебания давления греющего пара свыше 0,02-0,03 МПа (0,2-0,3 кгс/см<sup>2</sup> );</div></div><div class="ACT_TEXT"><div name="985675" id="985675">б) следить за поступлением и температурой охлаждающей воды конденсаторов, дифлегматоров и холодильников, не допуская возможности попадания в нее продуктов перегонки;</div></div><div class="ACT_TEXT"><div name="985677" id="985677">в) поддерживать установленное технологическим режимом, распределение температур и давлений в ректификационной установке;</div></div><div class="ACT_TEXT"><div name="985678" id="985678">г) производить отбор сортовых продуктов из ректификационного аппарата в соответствии с установленной технологической инструкцией;</div></div><div class="ACT_TEXT"><div name="985679" id="985679">д) обеспечить отвод конденсата из греющих поверхностей ректификационной установки, систематически проверять качество конденсата (химическим анализом);</div></div><div class="ACT_TEXT"><div name="985680" id="985680">е) следить за герметичностью аппаратуры и арматуры ректификационной установки, не допускать потерь перегоняемой смеси или продуктов перегонки через неплотности арматуры, соединении и пр. Установить контроль за температурой и качеством отходящей воды из греющих камер, поверхностных конденсаторов и др. для предупреждения возможности попадания в них продуктов перегонки;</div></div><div class="ACT_TEXT"><div name="985681" id="985681">ж) установить контроль над состоянием и работой автоматических регулирующих приборов, арматуры, контрольно-измерительных приборов и вспомогательным оборудованием ректификационной установки.</div></div><div class="ACT_TEXT"><div name="985682" id="985682">8. При использовании в ректификационных установках пара разных параметров (острый пар, отработанный пар и др.) должны быть установлены отдельные конденсатоотводчики. Не допускается отвод конденсата пара разных параметров на общий конденсационный горшок.</div></div><div class="ACT_TEXT"><div name="985683" id="985683">Конденсат пара разных параметров в зависимости от его качества и возможности использования необходимо направлять в общие или отдельные конденсатосборные баки.</div></div><div class="BY_DEFAULT"><div name="985684" id="985684"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985685" id="985685">ПРИЛОЖЕНИЕ № 15<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985686" id="985686">Технические требования при эксплуатации установок для термовлажностной обработки железобетонных изделий</div></div><div class="BY_DEFAULT"><div name="985687" id="985687"></div></div><div class="ACT_TEXT"><div name="985689" id="985689">1. При применении для обогрева изделий электрической энергии, продуктов сгорания природного газа, горячего воздуха и др. эксплуатация установок производится по инструкциям, утвержденным в установленном порядке.</div></div><div class="ACT_TEXT"><div name="985692" id="985692">2. Стены установок должны быть выполнены из нетеплоемкого и малотеплопроводного материала. Выбор материала и толщина стен должны быть обоснованы теплотехническими расчетами. В случае применения теплопроводного материала (сталь и др.) необходимо применять теплоизоляцию.</div></div><div class="ACT_TEXT"><div name="985700" id="985700">3. Бетонный пол установок должен иметь гидроизоляцию на утепленном слое и для стока конденсата в канализацию через гидрозатвор должен иметь уклон не менее 0,005.</div></div><div class="ACT_TEXT"><div name="985693" id="985693">4. Крышки пропарочных камер должны обеспечивать их полную герметизацию путем гидрозатвора или другой специальной конструкцией и соответственно должны иметь металлический каркас и теплоизоляционный слой, защищенный с двух сторон металлическими листами толщиной 3-4 мм. Крышки должны воспринимать статические и динамические нагрузки. Верхняя обшивка крышек камер, эксплуатируемых на полигоне, должна быть водонепроницаемой.</div></div><div class="ACT_TEXT"><div name="985694" id="985694">Крышки пропарочных камер должны обеспечивать их полную герметизацию путем гидравлического затвора или другим устройством специальной конструкции.</div></div><div class="ACT_TEXT"><div name="985695" id="985695">При изменении гидрозатворов рекомендуется:</div></div><div class="ACT_TEXT"><div name="985696" id="985696">а) крышки пропарочных камер выполнять жесткими из стального каркаса и обшивки с теплоизоляцией (минеральная вата и др.). Нижнюю поверхность крышки целесообразно выполнять с уклонами к боковым сторонам во избежание капели на изделия и для своевременного пополнения гидрозатвора водой (конденсатом). При недостаточном поступлении конденсата в гидрозатвор необходимо иметь устройство для подпитки гидрозатвора водой;</div></div><div class="ACT_TEXT"><div name="985697" id="985697">б) гидравлический затвор между крышкой и стенкой исполняется из швеллера, лежащего на верхнем обрезе стен, в который сверху опускается контурное вертикальное ребро, приваренное к крышке;</div></div><div class="ACT_TEXT"><div name="985698" id="985698">в) во избежание прорыва пара под швеллером гидрозатвора, к последнему приваривается вертикальное ребро, заделываемое в кладку стен;</div></div><div class="ACT_TEXT"><div name="985699" id="985699">г) засыпка гидрозатвора песком или опилками запрещается.</div></div><div class="ACT_TEXT"><div name="985701" id="985701">5. Клапаны, отъединяющие отдельные установки от магистрального вентиляционного канала, должны обеспечивать герметичное отключение камер.</div></div><div class="ACT_TEXT"><div name="985702" id="985702">6. Установки непрерывного действия с периодическим или непрерывным поступлением изделий для пропаривания должны иметь на входе и выходе изделий плотные, легко открывающиеся и закрывающиеся заслонки или гибкие шторы.</div></div><div class="ACT_TEXT"><div name="985703" id="985703">7. Пар в установки должен подаваться через перфорированные трубы с отверстиями диаметром не менее 5-6 мм, расположенные в нишах у пола камеры по ее периметру. Перфорированные трубы должны укладываться с наклоном и дренажем в нижних точках для стока конденсата.</div></div><div class="ACT_TEXT"><div name="985704" id="985704">Возможно устройство вертикальных перфорированных стояков, вваренных в кольцевой коллектор. Отверстия в перфорированных вертикальных стояках должны быть расположены таким образом, чтобы вытекающие из них струи создавали замкнутое движение паровоздушной среды, обеспечивающее выравнивание температуры в разных зонах камеры.</div></div><div class="ACT_TEXT"><div name="985705" id="985705">8. Установки тепловой обработки железобетонных изделий в щелевых камерах непрерывного действия должны отвечать следующим требованиям:</div></div><div class="ACT_TEXT"><div name="985706" id="985706">паропроводы и конденсатопроводы, запорная и регулирующая арматура, а также датчики автоматизированной системы управления должны располагаться в проходных туннелях вдоль камер. Проходные туннели для обслуживания камер должны быть оборудованы приточно-вытяжной вентиляцией и стационарной сетью электрического освещения; </div></div><div class="ACT_TEXT"><div name="985707" id="985707">камеры на входе и выходе должны быть оборудованы дверями с механическим приводом или шторами из теплостойкой резиновой ленты. Двери камер при загрузке и выгрузке должны открываться и закрываться поочередно;</div></div><div class="ACT_TEXT"><div name="985708" id="985708">между зоной активной обработки и зоной охлаждения должны быть четырехрядные шторы из теплостойкой резиновой ленты;</div></div><div class="ACT_TEXT"><div name="985709" id="985709">нагрев и обработка изделий в зоне активной тепловой обработки должны осуществляться горячим воздухом, подогретым паровыми стальными регистрами. Регистры устанавливаются на полу и под потолком и объединяются в группы соответственно количеству поддонов, на которых стоят детали. Циркуляция воздуха в камере осуществляется вентиляторами.</div></div><div class="ACT_TEXT"><div name="985710" id="985710">9. Установки, работающие под избыточным давлением 0,07 МПа (0,7 кгс/см<sup>2</sup>), и автоклавы должны быть оборудованы:</div></div><div class="ACT_TEXT"><div name="985711" id="985711">расходомерами пара;</div></div><div class="ACT_TEXT"><div name="985712" id="985712">регулятором давления и предохранительными клапанами пружинного или рычажного типа;</div></div><div class="ACT_TEXT"><div name="985713" id="985713">термометрами, установленными в нижней и верхней зонах для измерения температуры внутри автоклава;</div></div><div class="ACT_TEXT"><div name="985714" id="985714">манометрами (рабочим и контрольным);</div></div><div class="ACT_TEXT"><div name="985715" id="985715">конденсатоотводчиками;</div></div><div class="ACT_TEXT"><div name="985716" id="985716">предохранительными блокировочными устройствами, исключающими пуск пара в автоклав при неполном закрытии крышек и их открытие при оставшемся давлении в автоклаве;</div></div><div class="ACT_TEXT"><div name="985717" id="985717">световой сигнализацией плотного закрытия крышек автоклава;</div></div><div class="ACT_TEXT"><div name="985718" id="985718">контрольной трубкой с вентилем для проверки наличия в автоклаве избыточного давления.</div></div><div class="ACT_TEXT"><div name="985719" id="985719">10. Для обеспечения нормального режима работы автоклава необходимо:</div></div><div class="ACT_TEXT"><div name="985720" id="985720">разогревать и охлаждать со скоростью не более 50 С/мин.;</div></div><div class="ACT_TEXT"><div name="985721" id="985721">поддерживать установленное режимной картой распределение температур в установке;</div></div><div class="ACT_TEXT"><div name="985722" id="985722">предусматривать использование теплоты отработанного пара в теплообменниках после окончания технологического процесса;</div></div><div class="ACT_TEXT"><div name="985723" id="985723">открывать крышки только после полного сброса давления.</div></div><div class="ACT_TEXT"><div name="985724" id="985724">11. В крупные изделия с большими полостями подачу пара рекомендуется производить в горизонтальные полости через сопла по их оси.</div></div><div class="ACT_TEXT"><div name="985725" id="985725">12. В целях увеличения производительности установок и сокращения расходов тепловой энергии необходимо принимать меры к сокращению времени загрузки и выгрузки, добиваться предельной интенсификации теплообмена с сохранением высокого качества изделий, подбирать наивыгоднейшие формы изделий и составы бетонной смеси. Коэффициент (степень) заполнения камер изделиями должен быть максимальным. На изготовление каждого вида изделий должны быть разработаны технологические карты.</div></div><div class="ACT_TEXT"><div name="985726" id="985726">13. Для интенсификации теплообмена необходимо иметь устройства для наиболее полного вытеснения воздуха из рабочего пространства установок и должна быть организована искусственная циркуляция паровоздушной среды путем целесообразного расположения изделий в установках с достаточными каналами для циркулирующей паровоздушной смеси и побуждением циркуляции с помощью вытекающих с большой скоростью струй пара или простейших вентиляторов.</div></div><div class="ACT_TEXT"><div name="985727" id="985727">14. Укладка изделий должна обеспечивать равномерный быстрый прогрев и хорошее смывание всех поверхностей теплоносителем. Расстояние от пола установки до низа изделий должно быть не менее 150 мм и выдерживаться с помощью прокладок. Между изделиями прокладки должны обеспечивать расстояние не менее 30 мм, а между крышкой и изделиями — не менее 50 мм. Если в установке укладывается несколько изделий, то между штабелями расстояние должно быть не больше 100 мм.</div></div><div class="ACT_TEXT"><div name="985728" id="985728">15. Режим термовлажностной обработки в установках циклического действия должен быть полностью автоматизирован. Контроль за режимом термовлажностной обработки в установках непрерывного и циклического действия должен вестись круглосуточно.</div></div><div class="BY_DEFAULT"><div name="985729" id="985729"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985730" id="985730">ПРИЛОЖЕНИЕ № 16<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985731" id="985731">Технические требования при эксплуатации систем отопления, вентиляции и горячего водоснабжения</div></div><div class="BY_DEFAULT"><div name="985732" id="985732"></div></div><div class="ACT_TEXT"><div name="985733" id="985733">1. При присоединении к одному тепловому узлу управления разнохарактерной нагрузки, как-то: отопительных приборов бытовых помещений, приточных вентиляторных установок и агрегатов воздушного отопления, отопительных приборов в цехах, установок горячего водоснабжения, технологических теплоиспользующих установок, каждый из этих видов нагрузки следует питать по самостоятельному ответвлению, присоединенному к коллектору узла управления.</div></div><div class="ACT_TEXT"><div name="985734" id="985734">2. Узел управления должен быть оборудован:</div></div><div class="ACT_TEXT"><div name="985735" id="985735">а) задвижками, отделяющими узел управления системы, от наружной тепловой сети;</div></div><div class="ACT_TEXT"><div name="985736" id="985736">б) задвижками, установленными на всех подающих и обратных ответвлениях трубопроводов;</div></div><div class="ACT_TEXT"><div name="985737" id="985737">в) редукционным клапаном, отрегулированным на рабочее давление местной системы, парового отопления;</div></div><div class="ACT_TEXT"><div name="985738" id="985738">г) предохранительным клапаном, установленным на линии редуцированного пара;</div></div><div class="ACT_TEXT"><div name="985739" id="985739">д) грязевиками, установленными на подающих и обратных теплопроводах водяных систем;</div></div><div class="ACT_TEXT"><div name="985740" id="985740">е) устройством для опорожнения и наполнения системы;</div></div><div class="ACT_TEXT"><div name="985741" id="985741">ж) элеватором или другим смесительным устройством для водяных отопительных систем бытовых помещений, если температура воды в подающих теплопроводах превышает расчетные для этих помещений;</div></div><div class="ACT_TEXT"><div name="985743" id="985743">з) ограничительной шайбой на линии отбора при непосредственном разборе сетевой воды на горячее водоснабжение;</div></div><div class="ACT_TEXT"><div name="985744" id="985744">и) автоматическим регулятором температуры и расхода на системе горячего водоснабжения и регулятором расхода на системе отопления;</div></div><div class="ACT_TEXT"><div name="985745" id="985745">к) пусковым и эксплуатационным дренажем.</div></div><div class="ACT_TEXT"><div name="985746" id="985746">3. Узел управления водяной тепловой сети должен быть оснащен следующими контрольно-измерительными приборами:</div></div><div class="ACT_TEXT"><div name="985747" id="985747">а) манометрами на подающем и обратном теплопроводах после основных задвижек и штуцерами для манометра перед основными задвижками;</div></div><div class="ACT_TEXT"><div name="985748" id="985748">б) термометрами на подающем и обратном теплопроводах ввода и гильзами для термометров на всех обратных теплопроводах;</div></div><div class="ACT_TEXT"><div name="985750" id="985750">в) расходомерами, установленными на подающем или обратном теплопроводе с подключенной тепловой нагрузкой 5 Гкал/час и более, а на линии отбора воды на горячее водоснабжение — водомерами;</div></div><div class="ACT_TEXT"><div name="985752" id="985752">г) штуцером для манометра и гильзой для термометра на подающей линии смешанной воды.</div></div><div class="ACT_TEXT"><div name="985754" id="985754">4. Узел управления паровой сети должен быть оборудован следующими контрольно-измерительными приборами: </div></div><div class="ACT_TEXT"><div name="985755" id="985755">а) манометром и термометром на вводе паропровода после основных задвижек;</div></div><div class="ACT_TEXT"><div name="985756" id="985756">б) манометрами перед редукционным клапаном и после него; </div></div><div class="ACT_TEXT"><div name="985757" id="985757">в) манометром на конденсатопроводе;</div></div><div class="ACT_TEXT"><div name="985758" id="985758">г) термометрами на линиях редуцированного пара и на конденсатопроводе;</div></div><div class="ACT_TEXT"><div name="985759" id="985759">д) расходомерами на паропроводе при подключенной нагрузке 2 Гкал/час (8,4 ГДж/час) и более.</div></div><div class="ACT_TEXT"><div name="985760" id="985760">5. Все верхние точки разводящих теплопроводов должны быть оборудованы воздуховыпускными устройствами, а все нижние точки — кранами для спуска воды и отвода конденсата.</div></div><div class="ACT_TEXT"><div name="985784" id="985784">6. Трубопроводы должны иметь уклоны, исключающие образование воздушных мешков и скопление конденсата.</div></div><div class="ACT_TEXT"><div name="985785" id="985785">7. Узловые точки внутрицеховых теплопроводов должны оборудоваться секционными задвижками (вентилями), дающими возможность отключения отдельных участков от всей системы.</div></div><div class="ACT_TEXT"><div name="985786" id="985786">8. Максимальную температуру на поверхности отопительных приборов следует принимать в зависимости от назначения отапливаемого помещения в соответствии с санитарными нормами.</div></div><div class="ACT_TEXT"><div name="985787" id="985787">9. Отопительные приборы должны иметь краны или вентили для регулирования теплоподачи приборов.</div></div><div class="ACT_TEXT"><div name="985788" id="985788">10. Эксплуатация системы парового отопления предприятия должна обеспечивать:</div></div><div class="ACT_TEXT"><div name="985789" id="985789">а) равномерный прогрев всех нагревательных приборов;</div></div><div class="ACT_TEXT"><div name="985790" id="985790">б) полную конденсацию пара, поступающего в нагревательные приборы, не допуская его пролета;</div></div><div class="ACT_TEXT"><div name="985800" id="985800">в) полный возврат конденсата из системы.</div></div><div class="ACT_TEXT"><div name="985801" id="985801">11. Эксплуатация системы водяного отопления предприятия должна обеспечивать:</div></div><div class="ACT_TEXT"><div name="985802" id="985802">а) равномерный прогрев всех нагревательных приборов;</div></div><div class="ACT_TEXT"><div name="985803" id="985803">б) отклонение температуры воды, возвращаемой из системы, от расчетной (по графику) не более чем на 2<sup>o</sup> С;</div></div><div class="ACT_TEXT"><div name="985804" id="985804">в) залив верхних точек системы;</div></div><div class="ACT_TEXT"><div name="985805" id="985805">г) давление в системе не должно превышать допустимого для нагревательных приборов;</div></div><div class="ACT_TEXT"><div name="985806" id="985806">д) среднегодовую утечку теплоносителя из местной системы, не превышающую в час 0,25% от объема воды работающей системы;</div></div><div class="ACT_TEXT"><div name="985807" id="985807">е) коэффициент смещения не менее расчетного.</div></div><div class="ACT_TEXT"><div name="985808" id="985808">12. Заполнение и подпитка независимых систем водяного отопления должны производиться умягченной деаэрированной водой из тепловых сетей. Скорость и порядок заполнения должны быть согласованы с энергоснабжающей организацией.</div></div><div class="ACT_TEXT"><div name="985809" id="985809">13. В процессе эксплуатации систем водяного и парового отопления надлежит:</div></div><div class="ACT_TEXT"><div name="985810" id="985810">а) подвергать детальному осмотру элементы системы (разводящие магистрали на чердаках, в подвалах и каналах), скрытые от постоянного наблюдения, не реже 1 раза в месяц;</div></div><div class="ACT_TEXT"><div name="985811" id="985811">б) подвергать детальному осмотру наиболее ответственные элементы системы (насосы, магистральная запорная арматура, контрольно-измерительная аппаратура, автоматические устройства) не реже 1 раза в неделю;</div></div><div class="ACT_TEXT"><div name="985812" id="985812">в) производить удаление воздуха из системы отопления согласно инструкции;</div></div><div class="ACT_TEXT"><div name="985813" id="985813">г) производить очистку наружной поверхности нагревательных приборов от пыли и грязи не реже 1 раза в неделю;</div></div><div class="ACT_TEXT"><div name="985814" id="985814">д) производить промывку установленных грязевиков, сроки промывки их устанавливаются в зависимости от степени загрязнения, определяемой по разности показаний манометров до и после грязевиков;</div></div><div class="ACT_TEXT"><div name="985815" id="985815">е) осуществлять повседневный контроль за температурой и давлением теплоносителя, за прогревом отопительных приборов и за температурой внутри помещений в контрольных точках, а также за утеплением отапливаемых помещений (состояние фрамуг, дверей, окон и т. п.).</div></div><div class="ACT_TEXT"><div name="985816" id="985816">14. После окончания отопительного сезона отопительные системы должны быть подвергнуты промывке до полного осветления воды преимущественно с применением сжатого воздуха или водой, подаваемой в количестве, превышающем нормальный расход в 4-5 раз.</div></div><div class="ACT_TEXT"><div name="985817" id="985817">Для защиты от коррозии системы должны быть постоянно заполнены деаэрированной водой, за исключением периода ремонта.</div></div><div class="ACT_TEXT"><div name="985818" id="985818">15. Перед началом отопительного сезона все системы отопления должны быть подвергнуты гидравлической опрессовке. Гидравлическая опрессовка должна производиться независимо от того, проводился ремонт системы или не проводился.</div></div><div class="ACT_TEXT"><div name="985820" id="985820">Гидравлическая опрессовка производится на прочность и плотность на:</div></div><div class="ACT_TEXT"><div name="985821" id="985821">а) узлах управления (ввода) давлением 1,25 рабочего. За рабочее давление принимается давление перед входной задвижкой со стороны сети;</div></div><div class="ACT_TEXT"><div name="985822" id="985822">б) элеваторных узлах, калориферах и водоподогревателях отопления и горячего водоснабжения — давлением 1,25 рабочего, но не ниже 1 МПа (10 кгс/см<sup>2</sup>);</div></div><div class="ACT_TEXT"><div name="985823" id="985823">в) системах отопления с чугунными отопительными приборами — давлением 1,25 рабочего, но не более 0,6 МПа (6 кгс/см<sup>2</sup>);</div></div><div class="ACT_TEXT"><div name="985825" id="985825">г) системах панельного и конвекторного отопления — давлением 1 МПа (10 кгс/см<sup>2</sup>);</div></div><div class="ACT_TEXT"><div name="985826" id="985826">д) системы горячего водоснабжения — давлением, равным рабочему в системе плюс 0,5 МПа (5 кгс/см<sup>2</sup>), но не более 1 МПа (10 кгс/см<sup>2</sup>).</div></div><div class="ACT_TEXT"><div name="985828" id="985828">Гидравлическое испытание должно производиться при положительных температурах наружного воздуха. При температуре наружного воздуха ниже нуля проверка плотности возможна лишь в исключительных случаях.</div></div><div class="ACT_TEXT"><div name="985831" id="985831">16. Все вновь присоединяющие системы горячего водоснабжения или включаемые после ремонта должны быть проверены на плотность на рабочее давление плюс 5 кгс/см<sup>2</sup>, но не более 10 кгс/см<sup>2</sup>.</div></div><div class="ACT_TEXT"><div name="985833" id="985833">Проверка плотности системы горячего водоснабжения производится при обязательном участии представителя энергоснабжающей организации (цеха), который принимает систему в эксплуатацию.</div></div><div class="ACT_TEXT"><div name="985835" id="985835">17. Расчетные шайбы и сопла элеваторов должны пломбироваться.</div></div><div class="ACT_TEXT"><div name="985836" id="985836">18. Паровые системы отопления с рабочим давлением до 0,07 МПа (0,7 кгс/см<sup>2</sup>) должны испытываться давлением 0,25 МПа (2,5 кгс/см<sup>2</sup>) в нижней точке системы; системы с рабочим давлением более 0,07 МПа — давлением, равным рабочему плюс 0,1 МПа (1 кгс/см<sup>2</sup>), но не менее 0,3 МПа (3 кгс/см<sup>2</sup>) в верхней точке системы.</div></div><div class="ACT_TEXT"><div name="985837" id="985837">19. Системы считаются выдержавшими испытание, если во время их проведения: </div></div><div class="ACT_TEXT"><div name="985838" id="985838">не обнаружено «потения» сварных швов или течи из нагревательных приборов, трубопроводов, арматуры и прочего оборудования; </div></div><div class="ACT_TEXT"><div name="985839" id="985839">при опрессовках водяных и паровых систем теплопотребления в течение 5 мин. падение давления не превысило 0,02 МПа (0,2 кгс/см<sup>2</sup>);</div></div><div class="ACT_TEXT"><div name="985840" id="985840">при опрессовках систем панельного отопления падение давления в течение 15 мин. не превысило 0,01 МПа (0,1 кгс/см<sup>2</sup>);</div></div><div class="ACT_TEXT"><div name="985841" id="985841">при опрессовке систем горячего водоснабжения падение давления в течение 10 мин не превысило 0,05 МПа (0,5 кгс/см<sup>2</sup>).</div></div><div class="ACT_TEXT"><div name="985842" id="985842">Результаты проверки оформляются актом проведения опрессовок.</div></div><div class="ACT_TEXT"><div name="985843" id="985843">Если результаты опрессовки не отвечают указанным условиям, необходимо выявить и устранить утечки, после чего провести повторную проверку на плотность системы.</div></div><div class="ACT_TEXT"><div name="985844" id="985844">При гидравлическом испытании должны применяться пружинные манометры класса точности не ниже 1,5, с диаметром корпуса не менее 160 мм, шкалой на номинальное давление около 4/3 измеряемого, ценой деления 0,01 МПа (0,1 кгс/см<sup>2</sup>), прошедшие поверку и опломбированные госповерителем.</div></div><div class="ACT_TEXT"><div name="985845" id="985845">20. Трубопроводы системы горячего водоснабжения необходимо прокладывать, как правило, из стальных оцинкованных труб. Для трубопроводов систем горячего водоснабжения допускается применение неоцинкованных стальных электросварных труб при неагрессивных свойствах нагреваемой воды, а также в открытых системах теплоснабжения, труб из пластических масс или стальных с покрытием внутренних поверхностей термостойкими материалами, разрешенными к применению.</div></div><div class="ACT_TEXT"><div name="985846" id="985846">21. Для поддержания требуемого давления в системе горячего водоснабжения, выполненной по закрытой схеме, на трубопроводе холодной воды перед водонагревателем I ступени обязательна установка регулятора давления «после себя».</div></div><div class="ACT_TEXT"><div name="985847" id="985847">22. В случае невозможности отрегулировать давление в сети трубопроводов систем горячего водоснабжения путем подбора соответствующих диаметров труб следует предусматривать установку диафрагм на циркуляционных трубопроводах водоразборных стояков системы. Диаметр отверстия должен быть не менее 5 мм. Если по расчету диаметр диафрагм менее 5 мм, то допускается вместо диафрагмы устанавливать краны для регулирования давления.</div></div><div class="ACT_TEXT"><div name="985849" id="985849">23. На промышленных предприятиях, где расход на горячее водоснабжение периодический и кратковременный, но с большими расходами, должны применяться баки-аккумуляторы или емкие водонагреватели.</div></div><div class="ACT_TEXT"><div name="985850" id="985850">24. В качестве источника тепла на отопление и горячее водоснабжение должен максимально использоваться пар вторичного вскипания после теплоиспользующих установок, посредством установки конденсатоохладителей или баков-аккумуляторов пара.</div></div><div class="ACT_TEXT"><div name="985851" id="985851">25. При установке для систем горячего водоснабжения открытых баков-аккумуляторов последний должен быть оборудован регулятором уровня, указателем уровня, сигнальной, переливной и выводной трубкой, сообщающей бак с атмосферой. Установка запорной арматуры на сигнальной и переливной трубах не допускается.</div></div><div class="ACT_TEXT"><div name="985852" id="985852">Корпус бака должен иметь антикоррозийное покрытие и тепловую изоляцию.</div></div><div class="ACT_TEXT"><div name="985854" id="985854">26. При непосредственном водоразборе для учета тепла и воды на горячее водоснабжение тепловой пункт или узел управления должен быть оборудован двумя расходомерами (водомерами), установленными на подающем и обратном трубопроводе.</div></div><div class="ACT_TEXT"><div name="985857" id="985857">27. До включения отопительной системы в эксплуатацию после ремонта должно быть проведено ее тепловое испытание.</div></div><div class="ACT_TEXT"><div name="985860" id="985860">Тепловые испытания должны проводиться при температурах теплоносителя, соответствующих наружным температурам в период испытания.</div></div><div class="ACT_TEXT"><div name="985861" id="985861">В процессе проведения тепловых испытаний должна производиться наладка и регулировка системы. Результаты испытаний оформляются актом.</div></div><div class="BY_DEFAULT"><div name="985862" id="985862"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985863" id="985863">ПРИЛОЖЕНИЕ № 17<br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985864" id="985864">Технические требования при эксплуатации агрегатов воздушного отопления и систем вентиляции </div></div><div class="BY_DEFAULT"><div name="985865" id="985865"></div></div><div class="ACT_TEXT"><div name="985866" id="985866">1. Калориферные установки систем приточной вентиляции и воздушного отопления должны обеспечивать заданную температуру воздуха внутри помещения при расчетной температуре наружного воздуха и выполнении заданного температурного графика теплофикационной воды путем автоматической регулировки.</div></div><div class="ACT_TEXT"><div name="985867" id="985867">При выключении вентилятора должна быть осуществлена автоматическая блокировка, обеспечивающая подачу теплоносителя с учетом исключения размораживания трубок отопительных устройств.</div></div><div class="ACT_TEXT"><div name="985868" id="985868">2. Устройство камер воздушного отопления и приточной вентиляции должно обеспечить полную герметичность в соединениях, как между секциями калорифера, так и между калориферами, вентиляторами и наружными ограждениями, а также плотность закрытия обводных каналов, необходимых для летних режимов.</div></div><div class="ACT_TEXT"><div name="985869" id="985869">3. Калориферы в установках воздушного отопления и приточной вентиляции при подсоединении к паровым тепловым сетям включаются параллельно, а при теплоснабжении от водяных тепловых сетей — как правило, последовательно или параллельно-последовательно, что должно быть обосновано в проекте установки.</div></div><div class="ACT_TEXT"><div name="985870" id="985870">В калориферных установках, присоединяемых к водяным сетям, должен осуществляться противоток сетевой воды по отношению к воздушному потоку.</div></div><div class="ACT_TEXT"><div name="985871" id="985871">4. Каждая калориферная установка должна быть снабжена отключающей арматурой на входе и выходе теплоносителя, а также гильзами для термометров на подающем и обратном трубопроводах.</div></div><div class="ACT_TEXT"><div name="985872" id="985872">Калориферные установки, работающие на паре, должны быть дополнительно оборудованы конденсатоотводчиками.</div></div><div class="ACT_TEXT"><div name="985873" id="985873">Калориферные установки производительностью 0,25 Гкал/час и более должны быть оборудованы измерительными диафрагмами.</div></div><div class="ACT_TEXT"><div name="985875" id="985875">5. Число смятых или погнутых ребер у калориферов должно быть не более 10%, заглушенных труб в одноходовых калориферах — не более 5%. В многоходовых калориферах количество заглушенных труб допускается не более 1%.</div></div><div class="ACT_TEXT"><div name="985876" id="985876">6. Отопительные и вентиляционные камеры должны иметь искусственное освещение, а также свободный доступ к установленному в них оборудованию для обслуживания и ремонта.</div></div><div class="ACT_TEXT"><div name="985877" id="985877">Камеры должны запираться.</div></div><div class="ACT_TEXT"><div name="985878" id="985878">7. Заслонки и дроссельные клапаны, служащие для регулирования расхода воздуха, должны легко открываться и закрываться и размещаться на участках воздуховодов, доступных для обслуживания. При невозможности свободного подхода к заслонкам и клапанам должен быть установлен дистанционный привод.</div></div><div class="ACT_TEXT"><div name="985879" id="985879">Каждый привод должен иметь сектор с указателем промежуточных и конечных положений клапана. Для правильного распределения воздуха по отдельным ответвлениям воздухопроводной сети должны устанавливаться шибера.</div></div><div class="ACT_TEXT"><div name="985880" id="985880">8. Всасывающие отверстия вентиляторов, не соединенные с воздуховодами, должны быть закрыты защитными сетками с размером ячейки от 15 до 25 мм.</div></div><div class="ACT_TEXT"><div name="985881" id="985881">9. Вращающиеся части приводных и передаточных валов и механизмов (шкивы, муфты, зубчатые колеса, ремни) должны быть надежно ограждены или заключены в неподвижно укрепленные кожухи в соответствии с действующими правилами техники безопасности.</div></div><div class="ACT_TEXT"><div name="985882" id="985882">10. Створки в фонарях и окнах, через которые осуществляется регулирование аэрации, расположенные выше 3 м от пола, должны снабжаться групповыми регулировочными механизмами с ручным или электрическим приводом.</div></div><div class="ACT_TEXT"><div name="985883" id="985883">11. Все воздуховоды должны быть окрашены масляной или специальной краской. Окраска должна систематически восстанавливаться.</div></div><div class="ACT_TEXT"><div name="985884" id="985884">12. На кожухе вентилятора и корпусе электродвигателя яркой краской должны быть нанесены стрелки, указывающие направление вращения роторов. Для осевых вентиляторов стрелки должны быть нанесены на воздуховоде.</div></div><div class="ACT_TEXT"><div name="985885" id="985885">13. Перед приемкой в эксплуатацию установок воздушного отопления вентиляционных систем после монтажа или реконструкции должны быть произведены испытания, определяющие эффективность работы установки и соответствие ее паспортным и проектным данным.</div></div><div class="ACT_TEXT"><div name="985886" id="985886">В процессе испытания должны определяться:</div></div><div class="ACT_TEXT"><div name="985887" id="985887">а) производительность, полный и статический напор вентиляторов;</div></div><div class="ACT_TEXT"><div name="985888" id="985888">б) число оборотов вентиляторов и электродвигателей;</div></div><div class="ACT_TEXT"><div name="985889" id="985889">в) установленная мощность и фактическая нагрузка электродвигателей;</div></div><div class="ACT_TEXT"><div name="985890" id="985890">г) распределение объемов воздуха и напоры по отдельным ответвлениям воздухопроводной сети, а также в концевых точках всех участков;</div></div><div class="ACT_TEXT"><div name="985891" id="985891">д) температура и относительная влажность приточного и удаляемого воздуха;</div></div><div class="ACT_TEXT"><div name="985892" id="985892">е) производительность калориферов по теплу;</div></div><div class="ACT_TEXT"><div name="985893" id="985893">ж) температура воды до и после калориферов;</div></div><div class="ACT_TEXT"><div name="985894" id="985894">з) температура и влажность воздуха до и после увлажнительных камер;</div></div><div class="ACT_TEXT"><div name="985895" id="985895">и) коэффициент очистки фильтров;</div></div><div class="ACT_TEXT"><div name="985896" id="985896">к) наличие подсоса или утечки воздуха по отдельным элементам установки (воздуховоды, фланцы, камеры, фильтры и т. д.);</div></div><div class="ACT_TEXT"><div name="985897" id="985897">л) гидравлическое сопротивление калориферов при расчетном расходе теплоносителя.</div></div><div class="ACT_TEXT"><div name="985898" id="985898">14. Испытание должно производиться при расчетной нагрузке по воздуху при температурах теплоносителя, соответствующих наружной температуре.</div></div><div class="ACT_TEXT"><div name="985899" id="985899">15. Перед началом испытания должно быть произведено устранение дефектов, выявленных при осмотре.</div></div><div class="ACT_TEXT"><div name="985900" id="985900">Недостатки, выявленные во время испытания и наладки вентиляционных систем, должны быть внесены в ведомости дефектов и в последующем устранены.</div></div><div class="ACT_TEXT"><div name="985901" id="985901">16. Порядок включения и отключения вентиляционных установок определяется местной инструкцией.</div></div><div class="ACT_TEXT"><div name="985903" id="985903">В нерабочее время и выходные дни отопительно-вентиляционные установки, при наличии дежурного отопления, должны выключаться.</div></div><div class="ACT_TEXT"><div name="985904" id="985904">17. Калориферы воздушного отопления и приточной вентиляции по мере загрязнения их, но не реже 1 раза в квартал, должны продуваться сжатым воздухом или паром.</div></div><div class="ACT_TEXT"><div name="985905" id="985905">Продувка перед отопительным сезоном обязательна. Во время эксплуатации следует периодически проверять степень запыленности воздушных фильтров и очищать их (регенерировать).</div></div><div class="ACT_TEXT"><div name="985906" id="985906">18. На летний период во избежание засорения все калориферы со стороны подвода воздуха должны закрываться.</div></div><div class="ACT_TEXT"><div name="985907" id="985907">Очистка воздуховодов от пыли должна производиться не реже двух раз в год, если по условиям эксплуатации не требуется более частая их очистка.</div></div><div class="ACT_TEXT"><div name="985908" id="985908">Защитные сетки и жалюзи перед вентиляторами должны очищаться от пыли и грязи не реже 1 раза в квартал.</div></div><div class="ACT_TEXT"><div name="985909" id="985909">19. Металлические воздухоприемные и выкидные шахты, а также наружные жалюзийные решетки должны иметь антикоррозийные покрытия, состояние которых должно ежегодно проверяться и восстанавливаться.</div></div><div class="BY_DEFAULT"><div name="985910" id="985910"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985911" id="985911">ПРИЛОЖЕНИЕ № 18 <br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985912" id="985912">Технические требования при эксплуатации теплообменных аппаратов</div></div><div class="BY_DEFAULT"><div name="985913" id="985913"></div></div><div class="ACT_TEXT"><div name="985914" id="985914">1. Каждый теплообменный аппарат должен быть снабжен заводской табличкой, на которой указываются:</div></div><div class="ACT_TEXT"><div name="985915" id="985915">а) наименование завода-изготовителя;</div></div><div class="ACT_TEXT"><div name="985916" id="985916">б) наименование изделия и его обозначение;</div></div><div class="ACT_TEXT"><div name="985917" id="985917">в) давление допустимое и пробное для греющей и нагреваемой сред, МПа (кгс/см<sup>2</sup>);</div></div><div class="ACT_TEXT"><div name="985918" id="985918">г) максимальная температура греющей среды, <sup>о</sup>С;</div></div><div class="ACT_TEXT"><div name="985919" id="985919">д) заводской номер, год изготовления.</div></div><div class="ACT_TEXT"><div name="985920" id="985920">2. За теплообменными аппаратами, работающими на паре, необходимо устанавливать пробоотборные устройства с холодильниками для контроля качества конденсата, а также предусматривать возможность отключения теплообменников от общей системы сбора конденсата и его дренажа при неудовлетворительном качестве.</div></div><div class="ACT_TEXT"><div name="985921" id="985921">3. Теплообменные аппараты необходимо оборудовать следующими контрольно-измерительными приборами:</div></div><div class="ACT_TEXT"><div name="985922" id="985922">манометрами — на входящих и выходящих трубопроводах греющей и нагреваемой сред (пара, горячей воды, технологических продуктов); </div></div><div class="ACT_TEXT"><div name="985923" id="985923">термометрами — на входящих и выходящих трубопроводах греющей и нагреваемой сред;</div></div><div class="BY_DEFAULT"><div name="1745926" id="1745926"></div></div><div class="ACT_TEXT"><div name="1745928" id="1745928">предохранительными клапанами в соответствии с требованиями правил Государственной инспекции «Саноатгеоконтехназорат»; </div></div><div class="CHANGES_ORIGINS"><label id="s1104"></label><div name="1745930" id="1745930">(абзац четвертый пункта 3 в редакции <a href="/acts/1745284?ONDATE=18.02.2011 00#1745311">приказа</a> начальника инспекции «Узгосэнергонадзор» от 26 января 2011 года № 1 (рег. № 1549-1 от 08.02.2011 г.) — СЗ РУ, 2011 г., № 6, ст. 53)</div></div><div class="ACT_TEXT"><div name="985925" id="985925">дренажными устройствами;</div></div><div class="ACT_TEXT"><div name="985926" id="985926">водоуказательными стеклами со стороны конденсирующегося теплоносителя.</div></div><div class="ACT_TEXT"><div name="985927" id="985927">4. Теплообменные аппараты должны периодически подвергаться химической или механической очистке.</div></div><div class="ACT_TEXT"><div name="985928" id="985928">5. Теплообменные аппараты должны подвергаться испытаниям на тепловую производительность не реже 1 раза в 5 лет.</div></div><div class="ACT_TEXT"><div name="985929" id="985929">6. Водоводяные подогреватели систем отопления и горячего водоснабжения должны испытываться на плотность согласно требованиям <a href="/acts/973665#985284">п. 21</a> приложения № 6 настоящих Правил. Для выявления утечек сетевой воды в трубопроводы системы горячего водоснабжения или перетекания водопроводной воды в трубопроводы тепловой сети из-за износа трубной системы водоводяных теплообменников или неплотности вальцовки плотность всех теплообменников периодически не реже 1 раза в 4 мес. должна проверяться под давлением, равным давлению в водопроводе или тепловой сети.</div></div><div class="ACT_TEXT"><div name="985930" id="985930">При давлении в водопроводе больше, чем в обратном трубопроводе тепловой сети, проверять плотность подогревателей в эксплуатационных условиях допускается химическим анализом сетевой воды в обратном трубопроводе после подогревателя. Ухудшение качества воды свидетельствует о неплотности трубок.</div></div><div class="ACT_TEXT"><div name="985931" id="985931">7. При обнаружении течи в вальцовке или в трубках водоподогревателей они должны быть остановлены на ремонт.</div></div><div class="ACT_TEXT"><div name="985932" id="985932">Установка заглушек на место поврежденной трубки допускается в качестве временной меры для устранения течи.</div></div><div class="ACT_TEXT"><div name="985933" id="985933">8. Теплообменные аппараты должны быть оборудованы автоматическими регуляторами температуры, обеспечивающими температуру нагреваемой среды в соответствии с графиком. При этом теплообменные аппараты, работающие на сетевой воде, должны возвращать ее в тепловую сеть с температурой, соответствующей температурному графику.</div></div><div class="ACT_TEXT"><div name="985934" id="985934">Для систем горячего водоснабжения температура горячей воды должна быть в пределах 55—75° С.</div></div><div class="ACT_TEXT"><div name="985935" id="985935">9. При вынужденной кратковременной остановке теплообменных аппаратов и дренировании системы и межтрубного пространства заполнение теплообменников водой должно производиться только после охлаждения трубных решеток. </div></div><div class="BY_DEFAULT"><div name="985936" id="985936"></div></div><div class="APPL_BANNER_LANDSCAPE_TITLE"><div name="985937" id="985937">ПРИЛОЖЕНИЕ № 19 <br />к <a href="/acts/973665#982707">Правилам</a> технической эксплуатации <br />теплоиспользующих установок и тепловых сетей </div></div><div class="ACT_TITLE_APPL"><div name="985938" id="985938">Технические требования при эксплуатации теплоизмерительных приборов и автоматических регуляторов тепловых процессов </div></div><div class="BY_DEFAULT"><div name="985939" id="985939"></div></div><div class="ACT_TEXT"><div name="985940" id="985940">1. Аппаратура контрольно-измерительных приборов, автоматики и теплотехнического контроля не должна подвергаться вибрации, превышающей значения, допускаемые по техническим условиям. Показания приборов теплотехнического контроля должны соответствовать установленному для каждого прибора классу точности. Состояние автоматических регуляторов тепловых процессов должно обеспечивать экономичную работу агрегатов, а состояние устройств технологической защиты — их надежное действие при нарушении нормального режима работы оборудования.</div></div><div class="ACT_TEXT"><div name="985941" id="985941">2. Клапаны, регулирующие расход воды и пара, должны постоянно поддерживаться плотными.</div></div><div class="ACT_TEXT"><div name="985942" id="985942">Проходные сечения регулирующих клапанов должны соответствовать расчетным характеристикам агрегатов.</div></div><div class="ACT_TEXT"><div name="985943" id="985943">3. Приборы, по которым ведется контроль работы агрегатов, а также приборы технического учета должны запираться и пломбироваться.</div></div><div class="ACT_TEXT"><div name="985944" id="985944">4. Прокладка кабеля по теплоизлучающим поверхностям в непосредственной близости от них не допускается.</div></div><div class="ACT_TEXT"><div name="985946" id="985946">5. Температура окружающего воздуха, влажность, вибрация, запыленность в местах установки приборов и аппаратуры должны быть в пределах значений, допускаемых стандартами, техническими условиями и паспортами на эту аппаратуру.</div></div><div class="ACT_TEXT"><div name="985948" id="985948">6. Питание автоматических регуляторов и схем дистанционного управления должны осуществляться от резервированного источника питания. Для контроля напряжения должна быть предусмотрена световая и звуковая сигнализация.</div></div><div class="ACT_TEXT"><div name="985949" id="985949">Исправность средств автоматического включения резервного электропитания должна периодически проверяться по графику, утвержденному главным инженером (энергетиком) предприятия. Маслонасосные и компрессорные установки, систем гидро- или пневмопривода регулирующей арматуры должны выполняться резервированными с автоматическим включением резервного механизма.</div></div><div class="ACT_TEXT"><div name="985951" id="985951">7. Для ремонта приборов, заполненных ртутью, лаборатория или цех теплового контроля и автоматики должны иметь специальное изолированное помещение, оборудованное в соответствии с требованиями промышленной санитарии и правил техники безопасности.</div></div><div class="ACT_TEXT"><div name="985953" id="985953">8. В лаборатории или цехе, осуществляющих надзор и эксплуатацию средств КИПиА, должны быть подробные схемы расстановки автоматических регуляторов и приборов, монтажные схемы с указанием маркировки, а также инструкции по эксплуатации.</div></div><div class="ACT_TEXT"><div name="985955" id="985955">9. Периодические поверки приборов производятся в промежутках между государственными поверками в сроки, указанные в следующей таблице.</div></div><div class="TABLE_STD" id="theDefCssID"><div name="985956" id="985956" class="tabBox"><table id="theTableID" style="PADDING-RIGHT: 0px; ; PADDING-LEFT: 0px; LEFT: 91px; PADDING-BOTTOM: 0px; WIDTH: 75.77%; BORDER-TOP-STYLE: none; PADDING-TOP: 0px; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TOP: 0px; HEIGHT: 373px; BORDER-BOTTOM-STYLE: none" cellspacing="1" cols="2" border="1">
<colgroup>
<col />
<col /></colgroup>
<tbody>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none">‎</td></tr>
<tr>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Наименование прибора‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">Срок поверки (не менее)‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Пружинные манометры, вакуумметры и мановакуумметры‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в год на месте установки или в лаборатории‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Тягомеры мембранные и колокольные‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в 2 года в лаборатории‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Термометры ртутные или жидкостные‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в год в лаборатории‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Термопары‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в год в лаборатории‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Термометры сопротивления‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в год в лаборатории‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Газоанализаторы автоматические на СО<sub><sup>2</sup> </sub>и СО + Н<sub>2</sub>‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в 6 месяцев на месте установки или в лаборатории‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Вторичные приборы солемеров‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в год в лаборатории‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Измерительные системы всех типов‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в год на месте установки или в лаборатории ‎</font></td></tr>
<tr>
<td style="TEXT-ALIGN: center"><font size="2">Теплосчетчики всех типов‎</font></td>
<td style="VERTICAL-ALIGN: middle; TEXT-ALIGN: center"><font size="2">один раз в 2 года в лаборатории‎</font></td></tr>
<tr>
<td style="BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td>
<td style="VERTICAL-ALIGN: middle; BORDER-TOP-STYLE: none; BORDER-RIGHT-STYLE: none; BORDER-LEFT-STYLE: none; TEXT-ALIGN: center; BORDER-BOTTOM-STYLE: none"><font size="2">‎</font></td></tr></tbody></table></div></div><div class="ACT_TEXT"><div name="985965" id="985965">10. Автоматические регуляторы тепловых процессов должны быть настроены на оптимальные условия согласно режимным картам оборудования и при работе агрегатов должны быть постоянно включены.</div></div><div class="ACT_TEXT"><div name="985966" id="985966">11. Максимальное рабочее давление, измеряемое прибором, не должно выходить за пределы 2/3 шкалы при спокойной нагрузке и половины шкалы при колеблющейся нагрузке. Измерение минимального давления рекомендуется производить в пределах не менее 1/3 шкалы.</div></div><div class="ACT_TEXT"><div name="985967" id="985967">Верхний предел шкалы регистрирующих и показывающих термометров должен быть равен максимальной температуре измеряемой среды. Верхний предел шкалы самопишущих манометров должен соответствовать полуторакратному рабочему давлению измеряемой среды.</div></div><div class="ACT_TEXT"><div name="985968" id="985968">12. При измерении температур в теплопроводах термометры должны устанавливаться наклонно к оси трубы против течения или вдоль оси трубы — на поворотах.</div></div><div class="ACT_TEXT"><div name="985969" id="985969">13. Для обозначения максимально допустимого давления на шкале прибора должна быть нанесена красная черта или прибор должен иметь дополнительную красную стрелку, движение которой не связано с передвижением рабочей стрелки. Нанесение красной черты на стекле прибора запрещается.</div></div><div class="ACT_TEXT"><div name="985970" id="985970">14. Присоединение пружинных манометров к паропроводам должно производиться через сифонную трубку.</div></div><div class="ACT_TEXT"><div name="985972" id="985972">15. Манометры должны присоединяться к трубопроводам и аппаратам через трехходовые краны с фланцами для присоединения контрольного прибора.</div></div><div class="ACT_TEXT"><div name="985973" id="985973">16. Диафрагмы расходомеров и скоростные водомеры должны устанавливаться на прямолинейных участках теплопровода в соответствии с действующими Правилами агентства «Узстандарт».</div></div><div class="ACT_TEXT"><div name="985974" id="985974">17. На поверхности, выступающей из трубы каждой измерительной диафрагмы, должны быть нанесены диаметры диафрагмы и теплопровода, стрелка, указывающая направление теплоносителя, и знаки «плюс» и «минус» для присоединения измерительного прибора.</div></div><div class="ACT_TEXT"><div name="985975" id="985975">18. Ремонт автоматических регуляторов и устройств дистанционного управления должен производиться во время ремонта основного оборудования.</div></div><br /><div class="PUBLICATION_ORIGIN"><label id="s1089"></label><div name="982685" id="982685">(Собрание законодательства Республики Узбекистан, 2006 г., № 9, ст. 66; 2011 г., № 6, ст. 53)</div></div></div>
                
            </div>
        </section>
        
    </div>
    
    <div style="display: none;">
<!-- START WWW.UZ TOP-RATING -->
<SCRIPT language="javascript" type="text/javascript">
		<!--
		top_js = "1.0"; top_r = "id=4079&r=" + escape(document.referrer) + "&pg=" + escape(window.location.href); document.cookie = "smart_top=1; path=/"; top_r += "&c=" + (document.cookie ? "Y" : "N")
		//-->
</SCRIPT>
<SCRIPT language="javascript1.1" type="text/javascript">
<!--
		top_js = "1.1"; top_r += "&j=" + (navigator.javaEnabled() ? "Y" : "N")
//-->
</SCRIPT>
<SCRIPT language="javascript1.2" type="text/javascript">
<!--
		top_js = "1.2"; top_r += "&wh=" + screen.width + 'x' + screen.height + "&px=" + (((navigator.appName.substring(0, 3) == "Mic")) ? screen.colorDepth : screen.pixelDepth)
//-->
</SCRIPT>
<SCRIPT language="javascript1.3" type="text/javascript">
<!--
		top_js = "1.3";
//-->
</SCRIPT>
<SCRIPT language="JavaScript" type="text/javascript">
		<!--
		top_rat = "&col=0C57A6&t=ffffff&p=DD7900"; top_r += "&js=" + top_js + ""; document.write('<a href="https://www.uz/rus/toprating/cmd/stat/id/4079" target="_blank"><img src="https://www.uz/plugins/top_rating/count/cnt.png?' + top_r + top_rat + '" width=88 height=31 border=0 alt="Топ рейтинг www.uz"></a>')//-->
</SCRIPT>
<NOSCRIPT>
		<A href="https://www.uz/rus/toprating/cmd/stat/id/4079" target="_blank">
				<img height="31" src="https://www.uz/plugins/top_rating/count/nojs_cnt.png?id=4079&pg=http%3A//lex.uz&col=0C57A6&t=ffffff&p=DD7900" width="88" border="0" alt="Топ рейтинг www.uz">
		</A>
</NOSCRIPT>
<!-- FINISH WWW.UZ TOP-RATING --></div>
</body>
</html>
<script> 
    function scrollText(hash) {
        location.href = "#" + hash;
        //$('html,body').animate({
        //    scrollTop: $(window).scrollTop() - 75
        //});
    }
</script>
<script>     
    //function scrollToElement(selector, time, verticalOffset) {
    //    time = typeof (time) != 'undefined' ? time : 1000;
    //    verticalOffset = typeof (verticalOffset) != 'undefined' ? verticalOffset : 0;
    //    element = $(selector);
    //    offset = element.offset();
    //    offsetTop = offset.top + verticalOffset;
    //    $('html, body').animate({
    //        scrollTop: offsetTop
    //    }, time);
    //}

    //jQuery.fn.extend({
    //    scrollToMe: function () {
    //        var x = jQuery(this).offset().top - 100;
    //        jQuery('html,body').animate({ scrollTop: x }, 500);
    //    }
    //});

    //function opentInAct(id) {
    //    $("#" + id).scrollToMe();
    //}

    $(document).ready(function () {
        $("#theDefCssID TABLE TD").css('display', '');
    });
</script>
<style>
    #divCont > DIV {
        margin-left: -2px;
        margin-right: -2px;
        padding-left: 2px;
        padding-right: 2px;
    }

    TD.fTD {
        width: 22px;
    }

    .OFFICIAL_SOUR_TEXT {
        display: none;
    }

    /*.document_view_body*/ header {
        clear: both;
        float: left;
        height: 36px;
        width: 100%;
        background-color: #2263a9;
    }

        /*.document_view_body header .logo {
            float: left;
            padding: 0 12px;
        }*/

        /*.document_view_body header nav.main_menu {
            float: none;
        }*/

        /*nav.main_menu {
        float: left;
        padding-left: 22px;
        position: relative;
        z-index: 9;
    }*/

        /*nav.main_menu > div {
            float: left;
            height: 34px;
            margin-top: 1px;
            width: 21px;
        }*/

        /*.document_view_body header nav.main_menu > ul {
        float: none;
        font-family: helvatica;
        font-size: 11px;
    }*/

        /*nav.main_menu > ul {
        float: left;
        font-size: 16px;
    }*/

        /*nav ul, nav ol {
        list-style: none outside none;
        margin: 0;
        padding: 0;
    }*/

        /*ul, ol {
        margin: 1em 0;
        padding: 0 0 0 40px;
    }*/


        /*.document_view_body header .logo a {
        display: block;
        width: 100%;
    }*/


        /*.document_view_body*/ header .logo a span {
            background: url("/images/bg/doc_v_logo.png") no-repeat scroll center center transparent;
            display: block;
            height: 36px;
            width: 85px;
        }

    /*.hover-popup {
        display: none;
        border: 1px solid #969696;
        border-radius: 5px;
        -moz-border-radius: 5px;
        -webkit-border-radius: 5px;
        -o-border-radius: 5px;
        -ms-border-radius: 5px;
        position: absolute;
        behavior: url(css/PIE.htc);
        box-shadow: 2px 2px 6px -2px #555;
        padding: 7px;
        background: #fdffde;
        bottom: 28px;
        left: 10px;
        max-width: 500px;
        text-overflow: ellipsis;
        white-space: nowrap;
        color: #000;
        overflow: hidden;
    }*/

    /*.pre-loader {
        text-align: center;
        width: 100%;
        padding-bottom: 0 !important;
    }*/

    /*.actondate {
        width: 385px;
        height: 46px;
        background-color: White;
        z-index: 2000;
        font-family: Arial;
        font-size: 14px;
        font-weight: bold;
        opacity: 0.7;
        padding-top: 10px;
        text-align: center;
        top: 37px;
    }*/
</style>
